Time-domain quantification of series of biomedical magnetic resonance spectroscopy signals

被引:2
|
作者
Vanhamme, L
Van Huffel, S
Van Hecke, P
van Ormondt, D
机构
[1] Katholieke Univ Leuven, Dept Elect Engn ESAT, B-3001 Louvain, Belgium
[2] Katholieke Univ Leuven, Biomed NMR Unit, B-3000 Louvain, Belgium
[3] Delft Univ Technol, Dept Appl Phys, NL-2600 AA Delft, Netherlands
关键词
MRS data quantification; AMARES; time series; SVD; nonlinear least squares;
D O I
10.1006/jmre.1999.1835
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Quantification of individual magnetic resonance spectroscopy (MRS) signals is possible in the time domain using interactive nonlinear least-squares fitting methods which provide maximum likelihood parameter estimates under certain assumptions or using fully automatic, but statistically suboptimal, black-box methods. In kinetic experiments time series of consecutive MRS spectra are measured in which information concerning the time evolution of some of the signal parameters is often present. The purpose of this paper is to show how AMARES, a representative example of the interactive methods, can be extended to the simultaneous processing of all spectra in the time series using the common information present in the spectra. We show that this approach yields statistically better results than processing the individual signals separately. (C) 1999 Academic Press.
引用
收藏
页码:120 / 130
页数:11
相关论文
共 50 条
  • [1] Multichannel quantification of biomedical magnetic resonance spectroscopy signals
    Vanhamme, L
    Van Huffel, S
    ADVANCED SIGNAL PROCESSING ALGORITHMS, ARCHITECTURES, AND IMPLEMENTATIONS VIII, 1998, 3461 : 237 - 248
  • [2] Quantification of body fluid compartmentalization by combined time-domain nuclear magnetic resonance and bioimpedance spectroscopy
    Segar, Jeffrey L.
    Balapattabi, Kirthikaa
    Reho, John J.
    Grobe, Connie C.
    Burnett, Colin M. L.
    Grobe, Justin L.
    AMERICAN JOURNAL OF PHYSIOLOGY-REGULATORY INTEGRATIVE AND COMPARATIVE PHYSIOLOGY, 2021, 320 (01) : R44 - R54
  • [3] BAYESIAN-ANALYSIS OF TIME-DOMAIN MAGNETIC-RESONANCE SIGNALS
    BRETTHORST, GL
    HUNG, CC
    DAVIGNON, DA
    ACKERMAN, JJH
    JOURNAL OF MAGNETIC RESONANCE, 1988, 79 (02): : 369 - 376
  • [4] Exact quantification of time signals in Pade-based magnetic resonance spectroscopy
    Belkic, Dzevad
    PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (10): : 2633 - 2670
  • [5] Fast Pade transform for exact quantification of time signals in Magnetic Resonance Spectroscopy
    Belkic, Dzevad
    ADVANCES IN QUANTUM CHEMISTRY, VOL 51, 2006, 51 : 157 - 233
  • [6] The removal of echo signals in terahertz time-domain spectroscopy
    Wang Ling-Hui
    Wang Ying-Xin
    Zhao Zi-Ran
    JOURNAL OF INFRARED AND MILLIMETER WAVES, 2013, 32 (03) : 265 - +
  • [7] Quantification of magnetic resonance spectroscopy signals with lineshape estimation
    Osorio-Garcia, M. I.
    Sima, D. M.
    Nielsen, F. U.
    Himmelreich, U.
    Van Huffel, S.
    JOURNAL OF CHEMOMETRICS, 2011, 25 (04) : 183 - 192
  • [8] Time-domain quantification of amplitude, chemical shift, apparent relaxation time T-2*, and phase by wavelet-transform analysis. Application to biomedical magnetic resonance spectroscopy
    Serrai, H
    Senhadji, L
    deCertaines, JD
    Coatrieux, JL
    JOURNAL OF MAGNETIC RESONANCE, 1997, 124 (01) : 20 - 34
  • [9] Fast Pade transform for optimal quantification of time signals from magnetic resonance spectroscopy
    Belkic, D
    Belkic, K
    INTERNATIONAL JOURNAL OF QUANTUM CHEMISTRY, 2005, 105 (05) : 493 - 510
  • [10] TIME-DOMAIN ELECTRON-PARAMAGNETIC-RESONANCE SPECTROSCOPY
    BRITT, RD