Investigations on radiation hardness of DEPFET sensors for the Belle II detector

被引:4
作者
Ritter, Andreas [1 ,2 ]
Andricek, Ladislav [1 ,2 ]
Kleinohl, Tobias [3 ]
Koffmane, Christian [1 ,2 ,4 ]
Luetticke, Florian [3 ]
Marinas, Carlos [3 ]
Moser, Hans-Guenther [1 ,2 ]
Ninkovic, Jelena [1 ,2 ]
Richter, Rainer [1 ,2 ]
Schaller, Gerhard [1 ,2 ]
Schnecke, Martina [1 ,2 ]
Schopper, Florian [1 ,2 ]
机构
[1] Max Planck Inst Phys & Astrophys, Halbleiterlab, D-80805 Munich, Germany
[2] Max Planck Inst Extraterr Phys, D-80805 Munich, Germany
[3] Univ Bonn, Inst Phys, D-53115 Bonn, Germany
[4] TU Berlin, Fac Elect Engn & Comp Sci Sensor & Actuator Syst, D-10587 Berlin, Germany
关键词
DEPFET; Radiation damage; Particle tracking detectors; Silicon dioxide; Silicon detector; MOS OXIDES; DEVICES; CHARGE; SIMULATION;
D O I
10.1016/j.nima.2013.04.069
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In the upgrade of the Belle detector at KEK (Tsukuba, japan) the two innermost layers of the vertex detector will be realized by a pixel detector (PXD) consisting of DEPFET (DEpleted P-channel Field Effect Transistor) matrices. As the position of the detector will be very close to the beam pipe, it will suffer from intense radiation levels. The main radiation background is the luminosity related 4-fermion final state radiation, which damages the silicon bulk material and the silicon dioxide from the gate contacts. With the dose expected at Belle II, the DEPFET suffers mainly from additional leakage current and increase in noise. In addition, defects in the silicon dioxide change transistor parameters, e.g. the threshold voltage. We will show results on the hardness factor of electrons after a 10 MeV electron irradiation which was performed in the dose and energy range relevant for the PXD. In addition, we present X-ray irradiations of DEPFET equivalent Lest structures and compare radiation hardness for different oxide parameters in the prototype production. (C) 2013 Published by Elsevier B.V.
引用
收藏
页码:79 / 83
页数:5
相关论文
共 17 条
[1]  
[Anonymous], 1999, THESIS U HAMBURG
[2]   MONTE-CARLO SIMULATION OF .2. PHOTON PROCESSES .2. COMPLETE LOWEST ORDER CALCULATIONS FOR 4-LEPTON PRODUCTION PROCESSES IN ELECTRON POSITRON COLLISIONS [J].
BERENDS, FA ;
DAVERVELDT, PH ;
KLEISS, R .
COMPUTER PHYSICS COMMUNICATIONS, 1986, 40 (2-3) :285-307
[3]   Geant4 simulation of a filtered X-ray source for radiation damage studies [J].
Guthoff, M. ;
Brovchenko, O. ;
de Boer, W. ;
Dierlamm, A. ;
Mueller, T. ;
Ritter, A. ;
Schmanau, M. ;
Simonis, H. -J. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2012, 675 :118-122
[4]  
KEK-High Energy Accelerator Research Organization, 2010, BELL 2 TECHN DES REP
[5]   NEW DETECTOR CONCEPTS [J].
KEMMER, J ;
LUTZ, G .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1987, 253 (03) :365-377
[6]   Front-end electronics for DEPFET pixel detectors at SuperBelle (BELLE II) [J].
Krueger, Hans .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 617 (1-3) :337-341
[7]   The Belle-II DEPFET pixel detector: A step forward in vertexing in the superKEKB flavour factory [J].
Marinas, C. ;
Vos, M. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 650 (01) :59-63
[8]  
Moll A., 2013, THESIS LUDWIG MAXIMI
[9]   Total ionizing dose effects in MOS oxides and devices [J].
Oldham, TR ;
McLean, FB .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2003, 50 (03) :483-499
[10]   A review of recent MOSFET threshold voltage extraction methods [J].
Ortiz-Conde, A ;
Sánchez, FJG ;
Liou, JJ ;
Cerdeira, A ;
Estrada, M ;
Yue, Y .
MICROELECTRONICS RELIABILITY, 2002, 42 (4-5) :583-596