High resolution 19F{1H} nuclear magnetic resonance spectroscopy and liquid chromatography-solid phase extraction-offline 1H nuclear magnetic resonance spectroscopy for conclusive detection and identification of cyanide in water samples

被引:8
作者
Mazumder, Avik [1 ]
Kumar, Ajeet [1 ]
Dubey, Devendra K. [1 ]
机构
[1] Def Res & Dev Estab, Vertox Lab, Jhansi Rd, Gwalior 474002, India
关键词
Cyanide; Chemical warfare; Nuclear magnetic resonance; Cyanohydrin; 1-Cyano-2,2,2-trifluoro-1-phenylethyl acetate (CTPA); HPLC-UV; LC-UV-SPE; Offline H-1 NMR; F-19{H-1} NmR; GAS-CHROMATOGRAPHY; NMR-SPECTROSCOPY; BLOOD CYANIDE; WHOLE-BLOOD; THIOCYANATE; ANIONS; MICROEXTRACTION; WASTEWATER; INJECTION; PROBE;
D O I
10.1016/j.chroma.2013.02.001
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We report herein a new, sensitive and efficient method for detection, identification and quantification of cyanide in water samples. Cyanide was converted (>95% yield) to its versatile and stable derivative, 1-cyano-2,2,2-trifluoro-1-phenylethyl acetate (CTPA).The crude reaction mixture was directly subjected to high resolution fluorine-19 nuclear magnetic resonance (F-19{H-1} NMR) spectroscopy. In order to do away with signal overlap and dynamic range problems associated with H-1 NMR spectroscopy, liquid chromatography with UV detection hyphenated to online solid phase extraction (LC-UV-SPE) was performed. The trapped and enriched CTPA was thereafter subjected to offline H-1 NMR spectroscopy. In this way the delta(1H), delta(19F) spectral signatures and LC-UV retention time were used for specific detection and identification and quantification of cyanide. The three techniques (viz. LC-UV and LC-UV-SPE followed by offline H-1 NMR and F-19{H-1} NMR spectroscopy) demonstrated good linearity (r(2) >0.99), reproducibility (inter-day RSD: 1.43-1.89%, 2.60-2.80%, 1.42-1.60; intra-day: RSD 1.20-1.38%, 3.21-3.25%, 1.00-1.19%), accuracy (recoveries: 95.1-97.2%, 77.5-82.8%, 96.8-98.9%) and LODs (1.31 mu g/mL, 4.24 mu g/mL, and 2.14 mu g/mL) respectively. Total time required for the analysis was similar to 3 h. Utility of the method was demonstrated by the detection and identification of spiked water samples. Since the derivative CTPA was volatile, could also be analyzed by GC-MS and GC-FTIR instruments. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:88 / 99
页数:12
相关论文
共 61 条
[1]  
American Society for testing and materials (ASTM), 1998, D699404 ASTM, P002
[2]   Determination of cyanide by cathodic stripping voltammetry at a rotating silver disk electrode [J].
Anh, NBH ;
Sharp, M .
ANALYTICA CHIMICA ACTA, 2000, 405 (1-2) :145-152
[3]  
[Anonymous], 2009, QDOCLABWIPT03, P30
[4]  
[Anonymous], 1998, D669601 ASTM
[5]  
[Anonymous], 1998, ANN BOOK ASTM STAND, V14.02, P76
[6]  
[Anonymous], 1999, OIA1677 US EPA
[7]  
Baker D.C., 1984, C CYAN ENV TUCS AZ, P37929
[8]  
Bakhmutov V.I., 2004, PRACTICAL NMR RELAXA, P64
[9]  
Bhattacharya R, 2009, HANDBOOK OF TOXICOLOGY OF CHEMICAL WARFARE AGENTS, P255, DOI 10.1016/B978-0-12-374484-5.00019-5
[10]   SPECTROPHOTOMETRIC DETERMINATION OF UNCOMPLEXED CYANIDE AND THIOCYANATE IN WASTEWATER WITH PARA-PHENYLENEDIAMINE [J].
BOTTO, RI ;
KARCHMER, JH ;
EASTWOOD, MW .
ANALYTICAL CHEMISTRY, 1981, 53 (14) :2375-2376