The use of holographic interferometry and electron speckle pattern interferometry for diffusion measurement in biochemical and pharmaceutical engineering applications

被引:28
作者
Axelsson, Anders [1 ]
Marucci, Mariagrazia [1 ]
机构
[1] Lund Univ, LTH, Fac Engn, Dept Chem Engn, SE-22100 Lund, Sweden
关键词
ESPI; Holographic laser interferometry; Diffusion; Gel; Membrane; Protein; Pharmaceutical; Bioseparation; Osmosis;
D O I
10.1016/j.optlaseng.2008.03.017
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In this review holographic interferometry and electron speckle pattern interferometry are discussed as efficient techniques for diffusion measurements in biochemical and pharmaceutical applications. Transport phenomena can be studied, quantitatively and qualitatively, in gels, liquids and membranes. Detailed information on these phenomena is required to design effective chromatography bioseparation processes using gel beads or ultrafiltration membranes, and in the design of control led-release pharmaceuticals using membrane-coated pellets or tablets. The influence of gel concentration, ion strength in the liquid and the size of diffusing protein molecules can easily be studied with good accuracy. When studying membranes, the resistance can be quantified, and it is also possible to discriminate between permeable and semi-permeable membranes. In this review the influence of temperature, natural convection and light deflection on the accuracy of the diffusion measurements is also discussed. (c) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:865 / 876
页数:12
相关论文
共 44 条
  • [1] Ahmed M, 1999, J CHEM TECHNOL BIOT, V74, P193, DOI 10.1002/(SICI)1097-4660(199903)74:3<193::AID-JCTB45>3.0.CO
  • [2] 2-K
  • [3] EXPERIMENTAL STUDIES OF RESTRICTED PROTEIN DIFFUSION IN AN AGAROSE MATRIX
    BOYER, PM
    HSU, JT
    [J]. AICHE JOURNAL, 1992, 38 (02) : 259 - 272
  • [4] Diffusion of macromolecules in polymer solutions and gels: A laser scanning confocal microscopy study
    Burke, MD
    Park, JO
    Srinivasarao, M
    Khan, SA
    [J]. MACROMOLECULES, 2000, 33 (20) : 7500 - 7507
  • [5] OPTICAL ERRORS ENCOUNTERED IN USING HOLOGRAPHIC-INTERFEROMETRY TO OBSERVE LIQUID BOUNDARY-LAYERS IN ELECTROCHEMICAL-CELLS
    CLIFTON, M
    SANCHEZ, V
    [J]. ELECTROCHIMICA ACTA, 1979, 24 (04) : 445 - 450
  • [6] Crank J., 1975, The Mathematics of Diffusion, V1
  • [7] CUSSLER E. L., 1997, DIFFUSION MASS TRANS
  • [8] Characterising drug release processes within controlled release dosage forms using the confocal laser scanning microscope
    Cutts, LS
    Hibberd, S
    Adler, J
    Davies, MC
    Melia, CD
    [J]. JOURNAL OF CONTROLLED RELEASE, 1996, 42 (02) : 115 - 124
  • [9] deBeer D, 1997, BIOTECHNOL BIOENG, V53, P151, DOI 10.1002/(SICI)1097-0290(19970120)53:2<151::AID-BIT4>3.0.CO
  • [10] 2-N