Magnetic particle imaging: Introduction to imaging and hardware realization

被引:79
作者
Buzug, Thorsten M. [1 ]
Bringout, Gael [1 ]
Erbe, Marlitt [1 ]
Graefe, Ksenija [1 ]
Graeser, Matthias [1 ]
Gruettner, Mandy [1 ]
Halkola, Aleksi [1 ]
Sattel, Timo F. [1 ]
Tenner, Wiebke [1 ]
Wojtczyk, Hanne [1 ]
Haegele, Julian [2 ]
Vogt, Florian M. [2 ]
Barkhausen, Joerg [2 ]
Luedtke-Buzug, Kerstin [1 ]
机构
[1] Med Univ Lubeck, Inst Med Engn, D-23538 Lubeck, Germany
[2] Univ Hosp Schleswig Holstein, Clin Radiol & Nucl Med, Lubeck, Germany
来源
ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK | 2012年 / 22卷 / 04期
关键词
Magnetic Particle Imaging; Nanoparticles; SPIOs; Medical Imaging; SPACE MPI MOUSE; FIELD-FREE LINE; ATHEROSCLEROTIC PLAQUE; NANOPARTICLES; RECONSTRUCTION; RESOLUTION; GENERATION; CANCER; SIGNAL;
D O I
10.1016/j.zemedi.2012.07.004
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Magnetic Particle Imaging (MPI) is a recently invented tomographic imaging method that quantitatively measures the spatial distribution of a tracer based on magnetic nanoparticles. The new modality promises a high sensitivity and high spatial as well as temporal resolution. There is a high potential of MPI to improve interventional and image-guided surgical procedures because, today, established medical imaging modalities typically excel in only one or two of these important imaging properties. MPI makes use of the non-linear magnetization characteristics of the magnetic nanoparticles. For this purpose, two magnetic fields are created and superimposed, a static selection field and an oscillatory drive field. If superparamagnetic iron-oxide nanoparticles (SPIOs) are subjected to the oscillatory magnetic field, the particles will react with a non-linear magnetization response, which can be measured with an appropriate pick-up coil arrangement. Due to the non-linearity of the particle magnetization, the received signal consists of the fundamental excitation frequency as well as of harmonics. After separation of the fundamental signal, the nanoparticle concentration can be reconstructed quantitatively based on the harmonics. The spatial coding is realized with the static selection field that produces afield-free point, which is moved through the field of view by the drive fields. This article focuses on the frequency-based image reconstruction approach and the corresponding imaging devices while alternative concepts like x-space MPI and field-free line imaging are described as well. The status quo in hardware realization is summarized in an overview of MPI scanners.
引用
收藏
页码:323 / 334
页数:12
相关论文
共 89 条
[1]  
Alexiou C, 2011, NANOMEDICINE BASIC C
[2]  
[Anonymous], J PHYS D, DOI DOI 10.1088/0022-3727/42/2/022001
[3]   New biomimetic constructs for improved in vivo circulation of superparamagnetic nanoparticles [J].
Antonelli, Antonella ;
Sfara, Carla ;
Mosca, Luca ;
Manuali, Elisabetta ;
Magnani, Mauro .
JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2008, 8 (05) :2270-2278
[4]   Nanomaterials: Applications in Cancer Imaging and Therapy [J].
Barreto, Jose A. ;
O'Malley, William ;
Kubeil, Manja ;
Graham, Bim ;
Stephan, Holger ;
Spiccia, Leone .
ADVANCED MATERIALS, 2011, 23 (12) :H18-H40
[5]  
Biederer S, 2009, J PHYS D, V42
[6]  
Biederer S, 2010, MAGNETIC NANOPARTICLES: PARTICLE SCIENCE, IMAGING TECHNOLOGY, AND CLINICAL APPLICATIONS, P60, DOI 10.1142/9789814324687_0008
[7]  
Bulte JW, 2008, P ISMRM, V16, P1675
[8]  
Chikazumi, 1964, PHYS MAGNETISM
[9]  
Erbe M, 2011, BIOMEDICAL TECHNOLOG, V56
[10]  
Erbe M, 2012, SPRINGER PROC PHYS, V140, P225