Breast MR imaging for cancer detection and implant evaluation potential pitfalls

被引:8
作者
Piccoli, CW [1 ]
Greer, JG [1 ]
Mitchell, DG [1 ]
机构
[1] THOMAS JEFFERSON UNIV HOSP,PHILADELPHIA,PA 19107
关键词
breast; prostheses; breast neoplasms; diagnosis;
D O I
10.1148/radiographics.16.1.63
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Magnetic resonance (MR) imaging of the breast is currently used for evaluation of both parenchymal disease and silicone gel implants. MR imaging has the potential to address questions raised or unanswered with traditional diagnostic imaging methods. However, lesion specificity and cancer sensitivity depend on multiple technical factors (ie, imaging parameters and contrast agent delivery) and biologic factors (ie, the menstrual status of the patient and the vascularity of the lesion), Although diagnostic criteria for parenchymal disease have been reported, overlap of malignant and benign enhancement profiles occurs, The accuracy of implant evaluation depends on the imaging parameters and knowledge of the implant type and surgical history, In addition, individual investigative imaging methods are diverse, causing difficulty in protocol development for the practicing radiologist. An awareness of the problematic factors in breast MR imaging will improve diagnostic accuracy and allow understanding of the limitations of the modality and individual patient examinations.
引用
收藏
页码:63 / 75
页数:13
相关论文
共 50 条
  • [41] LOCAL ADVANCED BREAST-CANCER - CONTRAST-ENHANCED SUBTRACTION MR-IMAGING OF RESPONSE TO PREOPERATIVE CHEMOTHERAPY
    GILLES, R
    GUINEBRETIERE, JM
    TOUSSAINT, C
    SPIELMAN, M
    RIETJENS, M
    PETIT, JY
    CONTESSO, G
    MASSELOT, J
    VANEL, D
    RADIOLOGY, 1994, 191 (03) : 633 - 638
  • [42] Laser therapy for breast cancer: MR imaging and histopathologic correlation
    Mumtaz, H
    HallCraggs, MA
    Wotherspoon, A
    Paley, M
    Buonaccorsi, G
    Amin, Z
    Wilkinson, I
    Kissin, MW
    Davidson, I
    Taylor, I
    Bown, SG
    RADIOLOGY, 1996, 200 (03) : 651 - 658
  • [43] SILICONE BREAST IMPLANTS INVIVO - MR IMAGING
    GORCZYCA, DP
    SINHA, S
    AHN, CY
    DEBRUHL, ND
    HAYES, MK
    GAUSCHE, VR
    SHAW, WW
    BASSETT, LW
    RADIOLOGY, 1992, 185 (02) : 407 - 410
  • [44] Automatic motion correction for breast MR imaging
    Zuo, CS
    Jiang, AP
    Buff, BL
    Mahon, TG
    Wong, TZ
    RADIOLOGY, 1996, 198 (03) : 903 - 906
  • [45] Breast disease: Dynamic spiral MR imaging
    Daniel, BL
    Yen, YF
    Glover, GH
    Ikeda, DM
    Birdwell, RL
    Sawyer-Glover, AM
    Black, JW
    Plevritis, SK
    Jeffrey, SS
    Herfkens, RJ
    RADIOLOGY, 1998, 209 (02) : 499 - 509
  • [46] CONTRAST-ENHANCED MR-IMAGING OF THE BREAST IN PATIENTS WITH BREAST IMPLANTS AFTER CANCER-SURGERY
    BONE, B
    ASPELIN, P
    ISBERG, B
    PERBECK, L
    VERESS, B
    ACTA RADIOLOGICA, 1995, 36 (02) : 111 - 116
  • [47] The potential influence of fine-needle aspiration on MR imaging of the breast
    Wiberg, MK
    Boné, B
    Aspelin, P
    ACTA RADIOLOGICA, 2000, 41 (03) : 222 - 226
  • [48] How to measure breast cancer tumoral size at MR imaging?
    Thomassin-Naggara, I.
    Siles, Pascale
    Trop, I.
    Chopier, J.
    Darai, E.
    Bazot, M.
    Uzan, S.
    EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (12) : E790 - E800
  • [49] Conformal microwave imaging for breast cancer detection
    Li, D
    Meaney, PM
    Paulsen, KD
    IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2003, 51 (04) : 1179 - 1186
  • [50] Value of a breast imaging unit in the detection of breast cancer in Mexico
    Ramirez-Galvan, Yazmin A.
    Cardona-Huerta, Servando
    Elizondo-Riojas, Guillermo
    Montemayor-Martinez, Alberto
    Morales-Escajeda, Jesus, I
    Herrera-Pena, Carlos E.
    ECANCERMEDICALSCIENCE, 2021, 15