Effect of Computed Tomography Dose on Quantitative Measurement and Automated Segmentation of Airway Tree

被引:7
作者
Yu Nan [1 ]
Xin Xiao-Min [1 ]
Li Yan [1 ]
Ma Jun-Chao [1 ]
Gao Jun-Gang [1 ]
Jin Chen-Wang [2 ]
Guo You-Min [1 ]
机构
[1] Xi An Jiao Tong Univ, Affiliated Hosp 1, Pet CT Ctr, Xian 710061, Peoples R China
[2] Xi An Jiao Tong Univ, Affiliated Hosp 1, Dept Radiol, Xian 710061, Peoples R China
关键词
Airway Diseases; Low-Dose CT; Quantitative Measurement; Lung; LUNG-CANCER; CT; MORTALITY; NODULES; DISEASE; SCANS; COPD;
D O I
10.1166/jmihi.2015.1558
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
A fully automated computerized scheme that can segment an airway depicted on computed tomography (CT) images has certain advantages, particularly its simplicity and reliability. However, the CT scanning dose may affect the obtained measurement. In this study, we investigate whether the low-dose CT can be used to quantitative analysis of airway dimensions, which were measured by a computerized scheme. The study comprises twelve lung chest CT examinations acquired from three dogs with different beam currents of 30, 50, 100, and 200 mAs. At each dose, the lumen diameters, wall area, and lumen area of the matched airways (n = 82) were measured by this scheme. The bronchial segmentation ability and the measurement variability at individual dose were compared to that obtained at 200 mAs. Finally, we found that the CT dose impacts the measurement variability of the airway diameter (P < 0.01) and of the percentage of wall area (WA%) (P < 0.05). To obtain the same image quality, a CT dose of no less than 50 mAs should be selected since the percentage of leakage and/or obstruction bronchus at 30 mAs was significantly different from that at 200 mAs (P < 0.00). In conclusion, the airway tree segmentation algorithms by the fully automated computerized scheme are feasible on low-dose CT at doses as low as 50 mAs. However, the scanning dose does affect the obtained measurements.
引用
收藏
页码:1519 / 1523
页数:5
相关论文
共 50 条
[31]   Quantitative Airway Assessment on Computed Tomography in Patients with α1-antitrypsin Deficiency [J].
Yamashiro, Tsuneo ;
Matsuoka, Shin ;
Estepar, Raul San Jose ;
Diaz, Alejandro ;
Newell, John D. ;
Sandhaus, Robert A. ;
Mergo, Patricia J. ;
Brantly, Mark L. ;
Murayama, Sadayuki ;
Reilly, John J. ;
Hatabu, Hiroto ;
Silverman, Edwin K. ;
Washko, George R. .
COPD-JOURNAL OF CHRONIC OBSTRUCTIVE PULMONARY DISEASE, 2009, 6 (06) :468-477
[32]   Quantitative computed tomography: what does airway obstruction look-like? [J].
Kallieri, Maria ;
Papaioannou, Andriana I. ;
Kostikas, Konstantinos ;
Bakakos, Petros ;
Loukides, Stelios .
JOURNAL OF THORACIC DISEASE, 2016, 8 (09) :E1044-E1046
[33]   Airway wall thickness and airflow limitations in asthma assessed in quantitative computed tomography [J].
Patyk, Mateusz ;
Obojski, Andrzej ;
Sokolowska-Dabek, Dabrowka ;
Parkitna-Patyk, Martyna ;
Zaleska-Dorobisz, Urszula .
THERAPEUTIC ADVANCES IN RESPIRATORY DISEASE, 2020, 14
[34]   Quantitative single-photon emission computed tomography/computed tomography for technetium pertechnetate thyroid uptake measurement [J].
Lee, Hyunjong ;
Kim, Ji Hyun ;
Kang, Yeon-koo ;
Moon, Jae Hoon ;
So, Young ;
Lee, Won Woo .
MEDICINE, 2016, 95 (27)
[35]   The effect of trauma backboards on computed tomography radiation dose [J].
Lee, A. Y. ;
Elojeimy, S. ;
Kanal, K. M. ;
Linnau, K. F. ;
Gunn, M. L. .
CLINICAL RADIOLOGY, 2016, 71 (05) :499.e1-499.e8
[36]   Deep Learning Algorithm for Automated Segmentation and Volume Measurement of the Liver and Spleen Using Portal Venous Phase Computed Tomography Images [J].
Ahn, Yura ;
Yoon, Jee Seok ;
Lee, Seung Soo ;
Suk, Heung-Il ;
Son, Jung Hee ;
Sung, Yu Sub ;
Lee, Yedaun ;
Kang, Bo-Kyeong ;
Kim, Ho Sung .
KOREAN JOURNAL OF RADIOLOGY, 2020, 21 (08) :987-997
[37]   Effect of Thermal Insulation on Image Quality and Radiation Dose in Polytrauma Computed Tomography [J].
Podsiadlo, Pawel ;
Chrzan, Robert ;
Liszka, Grzegorz ;
Sanak, Tomasz ;
Kosinski, Sylweriusz ;
Urbanik, Andrzej ;
Darocha, Tomasz .
CANADIAN ASSOCIATION OF RADIOLOGISTS JOURNAL-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 2020, 71 (02) :238-243
[38]   Limitations of Airway Dimension Measurement on Images Obtained Using Multi-Detector Row Computed Tomography [J].
Oguma, Tsuyoshi ;
Hirai, Toyohiro ;
Niimi, Akio ;
Matsumoto, Hisako ;
Muro, Shigeo ;
Shigematsu, Michio ;
Nishimura, Takashi ;
Kubo, Yoshiro ;
Mishima, Michiaki .
PLOS ONE, 2013, 8 (10)
[39]   Prognostic effect of implementation of the mass low-dose computed tomography lung cancer screening program: a hospital-based cohort study [J].
Wu, Fu-Zong ;
Huang, Yi-Luan ;
Wu, Yun-Ju ;
Tang, En-Kuei ;
Wu, Ming-Ting ;
Chen, Chi-Shen ;
Lin, Yun-Pei .
EUROPEAN JOURNAL OF CANCER PREVENTION, 2020, 29 (05) :445-451
[40]   Automated method for structural segmentation of nasal airways based on cone beam computed tomography [J].
Tymkovych, Maksym Yu. ;
Avrunin, Oleg G. ;
Paliy, Victor G. ;
Filzow, Maksim ;
Gryshkov, Oleksandr ;
Glasmacher, Birgit ;
Omiotek, Zbigniew ;
Dzierzak, Roza ;
Smailova, Saule ;
Kozbekova, Ainur .
PHOTONICS APPLICATIONS IN ASTRONOMY, COMMUNICATIONS, INDUSTRY, AND HIGH ENERGY PHYSICS EXPERIMENTS 2017, 2017, 10445