摘要
Background: To compare two different techniques of proximal pin placement for the treatment of intertrochanteric fractures in elderly patients utilizing the Orthofix Pertrochanteric Fixator. Methods: Seventy elderly high-risk patients with an average age of 81 years were treated surgically for intertrochanteric fracture, resulting from a low energy trauma. Patients were randomly divided in two groups regarding to the proximal pin placement technique. In Group A the proximal pins were inserted in a convergent way, while in Group B were inserted in parallel. Results: All fractures healed uneventfully after a mean time of 98 days. The fixator was well accepted and no patient had significant difficulties while sitting or lying. The mean VAS score was 5.4 in group A and 5.7 in group B. At 12 months after surgery, in group A the average Harris Hip Score and the Palmer and Parker mobility score was 67 and 5.8, respectively. In group B, the average Harris Hip Score and the Palmer and Parker mobility score was 62 and 5.6, respectively. No statistically significant difference was found regarding the functional outcome. The mean radiographic exposure during pin insertion in Group A and Group B was 15 and 6 seconds, respectively. The difference between the two groups, regarding the radiographic exposure, was found to be significant. Conclusion: Proximal screw placement in a parallel way is simple, with significant less radiation exposure and shorter intraoperative duration. In addition, fixation stability is equal compared to convergent pin placement.
引用
收藏
页数:7
相关论文
共 28 条
[1]  
Badras L, 1997, REV CHIR ORTHOP, V83, P461
[2]   THE VALUE OF THE TIP-APEX DISTANCE IN PREDICTING FAILURE OF FIXATION OF PERITROCHANTERIC FRACTURES OF THE HIP [J].
BAUMGAERTNER, MR ;
CURTIN, SL ;
LINDSKOG, DM ;
KEGGI, JM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1995, 77A (07) :1058-1064
[3]   FIXATION OF INTERTROCHANTERIC FRACTURES OF THE FEMUR - A RANDOMIZED PROSPECTIVE COMPARISON OF THE GAMMA-NAIL AND THE DYNAMIC HIP SCREW [J].
BRIDLE, SH ;
PATEL, AD ;
BIRCHER, M ;
CALVERT, PT .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1991, 73 (02) :330-334
[4]   EXTERNAL FIXATION IN COMMINUTED UPPER FEMORAL FRACTURES [J].
BUCKLEY, JR ;
CAIACH, SM .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1993, 24 (07) :476-478
[5]  
Christodoulou NA, 2000, CLIN ORTHOP RELAT R, P204
[6]   Specialty update - What's new in orthopaedic trauma [J].
Cole, Peter A. ;
Bhandari, Mohit .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2006, 88A (11) :2545-2561
[7]   Biological fixation of subtrochanteric fractures by external fixation [J].
Dhal, A ;
Singh, SS .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1996, 27 (10) :723-731
[8]  
FORNANDER P, 1994, INT J ORTHOP TRAUMA, V4, P118
[9]   ANALYSIS OF SURGICAL BLOOD USE IN UNITED-STATES HOSPITALS WITH APPLICATION TO THE MAXIMUM SURGICAL BLOOD ORDER SCHEDULE [J].
FRIEDMAN, BA .
TRANSFUSION, 1979, 19 (03) :268-278
[10]  
GOTFRIED Y, 1985, ORTHOPEDICS, V8, P769