Reproducibility of Macular Thickness Measurement Among Five OCT Instruments: Effects of Image Resolution, Image Registration, and Eye Tracking

被引:21
作者
Chin, Eric K. [1 ]
Sedeek, Ragui W. [1 ]
Li, Yueju [2 ]
Beckett, Laurel [2 ]
Redenbo, Ellen [1 ]
Chandra, Karishma [1 ]
Park, Susanna S. [1 ]
机构
[1] Univ Calif Davis, Ctr Eye, Dept Ophthalmol & Vis Sci, Sacramento, CA 95817 USA
[2] Univ Calif Davis, Sch Med, Dept Publ Hlth Sci, Davis, CA 95616 USA
关键词
OPTICAL COHERENCE TOMOGRAPHY; SPECTRAL-DOMAIN-OCT; CIRRUS HD-OCT; RETINAL THICKNESS; TIME-DOMAIN; QUANTITATIVE ASSESSMENT; VISUAL-ACUITY; EDEMA; STRATUS; DEGENERATION;
D O I
10.3928/15428877-20111222-02
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
BACKGROUND AND OBJECTIVE: To study the effect of image resolution, eye tracking, and image registration on central macular thickness reproducibility (rCMT) among spectral-domain and time-domain optical coherence tomography (SD-OCT and TD-OCT) instruments. PATIENTS AND METHODS: Seventy-six eyes were imaged (44 normal, 32 maculopathy) either twice using four SD-OCT and one TD-OCT devices or three times using Spectralis SD-OCT (with and without eye tracking) (Heidelberg Engineering, Inc., Heidelberg, Germany). Cirrus images (Carl Zeiss Meditec, Dublin, CA) were further analyzed with three-point image registration. RESULTS: All instruments had superior rCMT in normal versus pathologic eyes (P < .001). No difference in rCMT was noted among instruments in normal eyes (P = .92), but TD-OCT was superior to SD-OCT (P = .017) in pathologic eyes. Cirrus image registration improved rCMT for normal eyes (P = .04), with borderline improvement in pathologic eyes (P = .06). Spectralis eye tracking improved rCMT in normal (P = .01) and pathologic (P = .004) eyes. CONCLUSION: Higher image resolution with SD-OCT may not improve rCMT, but image registration and eye tracking options may improve rCMT.
引用
收藏
页码:97 / 108
页数:12
相关论文
共 44 条
[1]   Clinical application of rapid serial Fourier-domain optical coherence tomography for macular imaging [J].
Alam, Suhail ;
Zawadzki, Robert J. ;
Choi, Stacey ;
Gerth, Christina ;
Park, Susanna S. ;
Morse, Lawrence ;
Werner, John S. .
OPHTHALMOLOGY, 2006, 113 (08) :1425-1431
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]   Comparison of StratusOCT and Cirrus HD-OCT Imaging in Macular Diseases [J].
Brennen, Peter M. ;
Kagemann, Larry ;
Friberg, Thomas R. .
OPHTHALMIC SURGERY LASERS & IMAGING, 2009, 40 (01) :25-31
[4]   Effect of eccentric and inconsistent fixation on retinal optical coherence tomography measures [J].
Campbell, Robert J. ;
Coupland, Stuart G. ;
Buhrmann, Ralf R. ;
Kertes, Peter J. .
ARCHIVES OF OPHTHALMOLOGY, 2007, 125 (05) :624-627
[5]   Normal macular thickness measurements in healthy eyes using stratus optical coherence tomography [J].
Chan, A ;
Duker, JS ;
Ko, TH ;
Fujimoto, JG ;
Schuman, JS .
ARCHIVES OF OPHTHALMOLOGY, 2006, 124 (02) :193-198
[6]   Randomized trial of peribulbar triamcinolone acetonide with and without focal photocoagulation for mild diabetic macular edema - A pilot study [J].
Chew, E. ;
Strauber, S. ;
Beck, R. ;
Aiello, L. P. ;
Antoszyk, A. ;
Bressler, N. ;
Browning, D. ;
Danis, R. ;
Fan, J. ;
Flaxel, C. ;
Friedman, S. ;
Glassman, A. ;
Kollman, C. ;
Lazarus, H. ;
Patel, S. ;
Callanan, D. ;
Elman, M. ;
Raden, R. ;
Sharuk, G. ;
Arrigg, P. ;
Schlossman, D. ;
Davidorf, F. ;
Chambers, R. ;
Li, H. ;
Drouilhet, J. ;
DiLoreto, D., Jr. ;
Benner, J. ;
Butler, J. ;
Chan, C. ;
Lin, S. ;
Lyon, A. ;
Mathura, J. ;
Ie, D. ;
Lipkowitz, J. ;
Shami, M. ;
Gonzalez, V. ;
Vann, V. ;
Wong, K. ;
Niffenegger, J. ;
Singerman, L. ;
Miller, D. ;
Gross, J. ;
Fishburne, B. ;
Garcia, Charles A. ;
Garcia, C. ;
Foster, W. ;
Baker, C. ;
Goodart, R. ;
Faber, D. ;
Mehr, D. .
OPHTHALMOLOGY, 2007, 114 (06) :1190-1196
[7]   Sensitivity advantage of swept source and Fourier domain optical coherence tomography [J].
Choma, MA ;
Sarunic, MV ;
Yang, CH ;
Izatt, JA .
OPTICS EXPRESS, 2003, 11 (18) :2183-2189
[8]   Spectral Domain OCT in age-related macular degeneration:: Preliminary results with Spectralis HRA-OCT® [J].
Coscas, G. ;
Coscas, F. ;
Vismara, S. ;
Souied, E. ;
Soubrane, G. .
JOURNAL FRANCAIS D OPHTALMOLOGIE, 2008, 31 (04) :353-361
[9]   Improved signal-to-noise ratio in spectral-domain compared with time-domain optical coherence tomography [J].
de Boer, JF ;
Cense, B ;
Park, BH ;
Pierce, MC ;
Tearney, GJ ;
Bouma, BE .
OPTICS LETTERS, 2003, 28 (21) :2067-2069
[10]   High-resolution spectral domain-OCT imaging in geographic atrophy associated with age-related macular degeneration [J].
Fleckenstein, Monika ;
Issa, Peter Charbel ;
Helb, Hans-Martin ;
Schmitz-Valckenberg, Steffen ;
Finger, Robert P. ;
Scholl, Hendrik P. N. ;
Loeffler, Karin U. ;
Holz, Frank G. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2008, 49 (09) :4137-4144