Biomechanical Comparison of Intramedullary Cortical Button Fixation and Interference Screw Technique for Subpectoral Biceps Tenodesis

被引:46
作者
Buchholz, Arne [1 ]
Martetschlaeger, Frank [1 ,5 ]
Siebenlist, Sebastian [1 ]
Sandmann, Gunther H. [1 ]
Hapfelmeier, Alexander [2 ]
Lenich, Andreas [1 ]
Millett, Peter J. [5 ]
Stoeckle, Ulrich [3 ]
Elser, Florian [4 ]
机构
[1] Tech Univ Munich, Univ Hosp Rechts Isar, Clin Trauma Surg, Emergency Dept, D-81675 Munich, Germany
[2] Tech Univ Munich, Univ Hosp Rechts Isar, Inst Med Stat & Epidemiol, D-81675 Munich, Germany
[3] Univ Tubingen, BG Trauma Ctr, Tubingen, Germany
[4] Hessingpk Clin, Augsburg, Germany
[5] Steadman Philippon Res Inst, Steadman Clin, Vail, CO USA
关键词
SOFT-TISSUE TENODESIS; LONG-HEAD; PROXIMAL BICEPS; MECHANICAL STRENGTH; IN-VITRO; TENDON; LESIONS; REPAIR; TENOTOMY; ANCHOR;
D O I
10.1016/j.arthro.2013.01.010
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: The purpose of this study was to biomechanically evaluate a new technique of intramedullary cortical button fixation for subpectoral biceps tenodesis and to compare it with the interference screw technique. Methods: We compared intramedullary unicortical button fixation (BicepsButton; Arthrex, Naples, FL) with interference screw fixation (Bio-Tenodesis screw; Arthrex) for subpectoral biceps tenodesis using 10 pairs of human cadaveric shoulders and ovine superficial digital flexor tendons. After computed tomography analysis, the specimens were mounted in a testing machine. Cyclic loading was performed (preload, 5 N; 5 to 70 N at 1.5 Hz for 500 cycles), recording the displacement of the tendon. Load to failure and stiffness were subsequently evaluated with a load-to-failure test (1 mm/s). Results: Cyclic loading showed a displacement of 11.3 +/- 2.8 mm for intramedullary cortical button fixation and 9 +/- 1.7 mm for interference screw fixation (P = .112). All specimens within the cortical button group passed the cyclic loading test, whereas 3 of 10 specimens within the interference screw group failed by tendon slippage at the screw-tendon-bone interface after a mean of 252 cycles (P = .221). Load-to-failure testing showed a mean load to failure of 218.8 +/- 40 N and stiffness of 27.2 +/- 7.2 N/mm for the intramedullary cortical button technique. For the interference screw, the mean load to failure was 212.1 +/- 28.3 N (P = .625) and stiffness was 40.4 +/- 13 N/mm (P = .056). Conclusions: We could not find any major differences in load to failure when comparing the tested techniques for subpectoral biceps tenodesis. Intramedullary cortical button fixation showed no failure during cyclic testing. However, we found a 30% failure rate (3 of 10) for the interference screw fixation. Clinical Relevance: Intramedullary cortical button fixation provides an alternative technique for subpectoral biceps tenodesis with comparable and, during cyclic loading, even superior biomechanical properties to interference screw fixation.
引用
收藏
页码:845 / 853
页数:9
相关论文
共 46 条
  • [41] Biceps Tenodesis With Interference Screw Fixation: A Biomechanical Comparison of Screw Length and Diameter
    Slabaugh, Maj Mark A.
    Frank, Rachel M.
    Van Thiel, Geoffrey S.
    Bell, Rebecca M.
    Wang, Vincent M.
    Trenhaile, Scott
    Provencher, Matthew T.
    Romeo, Anthony A.
    Verma, Nikhil N.
    [J]. ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2011, 27 (02) : 161 - 166
  • [42] Effects of three different preservation methods on the mechanical properties of human and bovine cortical bone
    Stefan, Unger
    Michael, Blauth
    Werner, Schmoelz
    [J]. BONE, 2010, 47 (06) : 1048 - 1053
  • [43] The proximal biceps as a pain generator and results of tenotomy
    Szabo, Istvan
    Boileau, Pascal
    Walch, Gilles
    [J]. SPORTS MEDICINE AND ARTHROSCOPY REVIEW, 2008, 16 (03) : 180 - 186
  • [45] Wingerter S, 2006, BIOMED SCI INSTRUM, V42, P290
  • [46] Graft laceration and pullout strength of soft-tissue anterior cruciate ligament reconstruction: In vitro study comparing titanium, poly-D,L-lactide, and poly-D,L-lactide-tricalcium phosphate screws
    Zantop, Thore
    Weimann, Andre
    Schmidtko, Rornana
    Herbort, Mirco
    Raschke, Michael J.
    Petersen, Wolf
    [J]. ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2006, 22 (11) : 1204 - 1210