A digital process for additive manufacturing of occlusal splints: a clinical pilot study

被引:97
作者
Salmi, Mika [1 ]
Paloheimo, Kaija-Stiina [1 ]
Tuomi, Jukka [1 ]
Ingman, Tuula [2 ,3 ]
Makitie, Antti [1 ,2 ,3 ]
机构
[1] Aalto Univ, Sch Sci, Dept Ind Engn & Management, BIT Res Ctr, POB 15500, Aalto 00076, Finland
[2] Univ Helsinki, Cent Hosp, Dept Otolaryngol Head & Neck Surg, Huch 00029, Finland
[3] Univ Helsinki, Huch 00029, Finland
关键词
computer-aided design; computer-aided manufacturing; additive manufacturing; rapid prototyping; rapid manufacturing; DEVELOPING FACIAL PROSTHESES; TEMPOROMANDIBULAR DISORDERS; CAD/CAM TECHNIQUES; DENTAL ATTRITION; TREATMENT NEED; MODELS; SIGNS; AGE; RECONSTRUCTION; DYSFUNCTION;
D O I
10.1098/rsif.2013.0203
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The aim of this study was to develop and evaluate a digital process for manufacturing of occlusal splints. An alginate impression was taken from the upper and lower jaws of a patient with temporomandibular disorder owing to cross bite and wear of the teeth, and then digitized using a table laser scanner. The scanned model was repaired using the 3DATA EXPERT software, and a splint was designed with the VISCAM RP software. A splint was manufactured from a biocompatible liquid photopolymer by stereolithography. The system employed in the process was SLA 350. The splint was worn nightly for six months. The patient adapted to the splint well and found it comfortable to use. The splint relieved tension in the patient's bite muscles. No sign of tooth wear or significant splint wear was detected after six months of testing. Modern digital technology enables us to manufacture clinically functional occlusal splints, which might reduce costs, dental technician working time and chair-side time. Maximum-dimensional errors of approximately 1 mm were found at thin walls and sharp corners of the splint when compared with the digital model.
引用
收藏
页数:6
相关论文
共 34 条
[1]   Anterior midline point stop device (AMPS) in the treatment of myogenous TMDs: Comparison with the stabilization splint and control group [J].
Al Quran, Firas A. M. ;
Kamal, Mudar S. .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2006, 101 (06) :741-747
[2]  
[Anonymous], 2012, F2792 ASTM INT, DOI [10.1520/F2792-12, DOI 10.1520/F2792-12)]
[3]   Comparison of three-dimensional computed tomography with rapid prototype models in the management of coronoid hyperplasia [J].
Asaumi, J ;
Kawai, N ;
Honda, Y ;
Shigehara, H ;
Wakasa, T ;
Kishi, K .
DENTOMAXILLOFACIAL RADIOLOGY, 2001, 30 (06) :330-335
[4]   Prediction of demand for treatment of temporomandibular disorders based on a 20-year follow-up study [J].
Carlsson, GE ;
Magnusson, T ;
Egermark, I .
JOURNAL OF ORAL REHABILITATION, 2004, 31 (06) :511-517
[5]  
Carlsson GE, 1999, J OROFAC PAIN, V13, P232
[6]  
Cheah CM, 2003, INT J PROSTHODONT, V16, P543
[7]  
Cheah CM, 2003, INT J PROSTHODONT, V16, P435
[8]   Analysis of errors in medical rapid prototyping models [J].
Choi, JY ;
Choi, JH ;
Kim, NK ;
Kim, Y ;
Lee, JK ;
Kim, MK ;
Lee, JH ;
Kim, MJ .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2002, 31 (01) :23-32
[9]   PREVALENCE IN THE DUTCH ADULT-POPULATION AND A METAANALYSIS OF SIGNS AND SYMPTOMS OF TEMPOROMANDIBULAR DISORDER [J].
DEKANTER, RJAM ;
TRUIN, GJ ;
BURGERSDIJK, RCW ;
VANTHOF, MA ;
BATTISTUZZI, PGFCM ;
KALSBEEK, H ;
KAYSER, AF .
JOURNAL OF DENTAL RESEARCH, 1993, 72 (11) :1509-1518
[10]  
Feng ZH, 2010, INT J PROSTHODONT, V23, P513