Differential pulsed amperometry coupled to microchip capillary electrophoresis

被引:8
作者
Li, Xinchun [1 ,2 ]
Chen, Zuanguang [1 ]
Pan, Jianbin [1 ]
Yang, Fan [1 ,3 ]
Li, Yinbao [1 ]
Yao, Meicun [1 ]
机构
[1] Sun Yat Sen Univ, Sch Pharmaceut Sci, Higher Educ Mega Ctr, Guangzhou 510006, Guangdong, Peoples R China
[2] Guangxi Med Univ, Sch Pharmaceut Sci, Nanning 530021, Peoples R China
[3] Chinese Acad Sci, Phys Biol Lab, Shanghai Inst Appl Phys, Shanghai 201800, Peoples R China
基金
中国国家自然科学基金;
关键词
Microfluidic; Capillary electrophoresis; Electrochemical detection; Differential pulsed amperometry; ELECTROCHEMICAL DETECTION; SINUSOIDAL VOLTAMMETRY; ELECTRODE; GOLD; SEPARATION; CHIP;
D O I
10.1016/j.chroma.2013.03.064
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this work, we describe a novel electrochemical detection method, differential pulsed amperometry (DPA) on microchip capillary electrophoresis (MCE). In a pulse period, a sequential two-step sampling is executed at two different potentials (E-1 and E-2). Differential current signal of the duplex sampling events is recorded that functions as time domain. The performance of this detection scheme was evaluated by separating and detecting three model analytes including tyramine (Tym), tryptophan (Trp), and p-aminobenzoic acid (PABA). Multiple parameters that would affect electrochemical response and peak shape, such as sampling potential, sampling time, and electrode cleaning time, were investigated. This pulse technique exhibits better sensitivity over constant potential amperometry (CPA), nearly equal to triple pulsed amperometry (TPA). More importantly, DPA can generate more stable baseline than TPA, primarily due to the background subtraction through the two-step sampling, which is beneficial to further improve analytical sensitivity. In the optimal condition, the limits of detection for Tym, Trp and PABA, were down to 0.27 mu M, 0.32 mu M and 1.1 mu M, respectively. DPA detection opens up a new avenue for microchip electrochemistry, and can be virtually extended to other fluid analysis techniques. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:174 / 178
页数:5
相关论文
共 29 条
[1]   PULSED ELECTROCHEMICAL DETECTION OF PENICILLINS USING 3-STEP AND 4-STEP WAVE-FORMS [J].
ALTUNATA, S ;
EARLEY, RL ;
MOSSMAN, DM ;
WELCH, LE .
TALANTA, 1995, 42 (01) :17-25
[2]   A chip-based electrophoresis system with electrochemical detection and hydrodynamic injection [J].
Backofen, U ;
Matysik, FM ;
Lunte, CE .
ANALYTICAL CHEMISTRY, 2002, 74 (16) :4054-4059
[3]   Capillary gel electrophoresis with sinusoidal voltammetric detection: A strategy to allow four-"color" DNA sequencing [J].
Brazill, SA ;
Kim, PH ;
Kuhr, WG .
ANALYTICAL CHEMISTRY, 2001, 73 (20) :4882-4890
[4]   Amperometric detector designs for capillary electrophoresis microchips [J].
Castaño-Alvarez, M ;
Fernández-Abedul, MT ;
Costa-García, A .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1109 (02) :291-299
[5]   Pulsed amperometric detection of carbohydrates on an electrophoretic microchip [J].
Fanguy, JC ;
Henry, CS .
ANALYST, 2002, 127 (08) :1021-1023
[6]   New analytical portable instrument for microchip electrophoresis with electrochemical detection [J].
Fernandez-la-Villa, Ana ;
Pozo-Ayuso, Diego F. ;
Castano-Alvarez, Mario .
ELECTROPHORESIS, 2010, 31 (15) :2641-2649
[7]   Coupling capillary electrophoresis and pulsed electrochemical detection [J].
García, CD ;
Henry, CS .
ELECTROANALYSIS, 2005, 17 (13) :1125-1131
[8]   Comparison of pulsed electrochemical detection modes coupled with microchip capillary electrophoresis [J].
García, CD ;
Henry, CS .
ELECTROANALYSIS, 2005, 17 (03) :223-230
[9]   Enhanced determination of glucose by microchip electrophoresis with pulsed amperometric detection [J].
García, CD ;
Henry, CS .
ANALYTICA CHIMICA ACTA, 2004, 508 (01) :1-9
[10]   Direct determination of carbohydrates, amino acids, and antibiotics by microchip electrophoresis with pulsed amperometric detection [J].
García, CD ;
Henry, CS .
ANALYTICAL CHEMISTRY, 2003, 75 (18) :4778-4783