Optimizing preparation design for metal-free composite resin crowns

被引:34
|
作者
Ohlmann, Brigitte [1 ]
Gruber, Rudolf [2 ]
Eickemeyer, Grit [1 ]
Rammelsberg, Peter [1 ]
机构
[1] Univ Heidelberg, Dept Prosthodont, D-69120 Heidelberg, Germany
[2] Univ Gottingen, Dept Oral & Maxillofacial Surg, Gottingen, Germany
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2008年 / 100卷 / 03期
关键词
D O I
10.1016/S0022-3913(08)60180-8
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Although composite resin materials are used for posterior crown restorations, the influence of preparation design, material thickness, convergence angle, and method of cementation on fracture resistance remains unclear. Purpose. The purpose of this in vitro study was to test the hypothesis that minimal preparation designs provide an acceptable level of fracture resistance for posterior composite resin crowns. Material and methods. Nonreinforced Artglass composite resin crowns (n=128) were fabricated on human molars in 16 test groups (n=8). Axial tooth preparation included a 1-mm-deep shoulder or a 0.5-mm chamfer preparation, whereas occlusal reduction was either 0.5 mm or 1.3 mm. The total angle of convergence was 4 or 11 degrees and the crowns were cemented either with glass ionomer cement (Ketac Cem) or resin cement (2bond2). After 10,000 thermal cycles, crowns were vertically loaded until failure occurred; load was measured in newtons. Statistical analysis was performed by a 4-way ANOVA (alpha=.05). Results. Statistical analysis revealed significant effects of occlusal thickness (P<.001), cement (P<.001), preparation design (P=.011), and convergence angle (P=.001) on the fracture resistance of the composite crowns. For composite resin crowns with an occlusal thickness of 0.5 mm, the resistance to fracture was lower than for crowns with a 1.3-mm thickness. Fracture resistance was greater when resin cement was used, and greater for the chamfer finish line than for the shoulder finish line. Use of a greater total convergence angle reduced fracture resistance. Conclusions. Fracture resistance of composite resin crowns was significantly improved by increasing the occlusal thickness of the crowns, by using resin cement, and by reducing the total convergence angle.
引用
收藏
页码:211 / 219
页数:9
相关论文
共 50 条
  • [1] Wear of metal-free resin composite crowns after three years in service
    Zenthoefer, Andreas
    Rammelsberg, Peter
    Schmitt, Clemens
    Ohlmann, Brigitte
    DENTAL MATERIALS JOURNAL, 2013, 32 (05) : 787 - 792
  • [2] The effect of preparation design on the marginal stress of resin-bonded metal-free crowns: A finite element study
    Shinya, Akikazu
    Lassila, Lippo V. J.
    Vallittu, Pekka K.
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2008, 21 (05) : 445 - 447
  • [3] Adhesively Luted, Metal-free Composite Crowns After Five Years
    Lehmann, Franziska
    Spiegl, Katrin
    Eickemeyer, Grit
    Rammelsberg, Peter
    JOURNAL OF ADHESIVE DENTISTRY, 2009, 11 (06): : 493 - 498
  • [5] Fracture resistance of posterior metal-free polymer crowns
    Rammelsberg, P
    Eickemeyer, G
    Erdelt, K
    Pospiech, P
    JOURNAL OF PROSTHETIC DENTISTRY, 2000, 84 (03): : 303 - 308
  • [6] PREPARATION OF METAL-FREE WATER
    RIORDAN, JF
    VALLEE, BL
    METHODS IN ENZYMOLOGY, 1988, 158 : 3 - 6
  • [7] PREPARATION OF METAL-FREE ENZYMES
    WAGNER, FW
    METHODS IN ENZYMOLOGY, 1988, 158 : 21 - 32
  • [8] Influence of abutment substrates on the colour of metal-free polymer crowns
    Nakamura, T
    Saito, O
    Mizuno, M
    Kinuta, S
    Ishigaki, S
    JOURNAL OF ORAL REHABILITATION, 2003, 30 (02) : 184 - 188
  • [9] Fracture resistance of metal-free composite crowns - Effects of fiber reinforcement, thermal cycling, and cementation technique
    Lehmann, F
    Eickemeyer, G
    Rammelsberg, P
    JOURNAL OF PROSTHETIC DENTISTRY, 2004, 92 (03): : 258 - 264
  • [10] A Simplified Isolation Technique for Preparation and Placement of Resin Composite Strip Crowns
    Psaltis, Gregory L.
    Kupietzky, Ari
    PEDIATRIC DENTISTRY, 2008, 30 (05) : 436 - 438