Screening for atrial fibrillation with automated blood pressure measurement: Research evidence and practice recommendations

被引:68
作者
Verberk, Willem J. [1 ,2 ]
Omboni, Stefano [3 ]
Kollias, Anastasios [4 ]
Stergiou, George S. [4 ]
机构
[1] Maastricht Univ, Cardiovasc Res Inst Maastricht CARIM, NL-6200 MD Maastricht, Netherlands
[2] Microlife AG, Widnau, Switzerland
[3] Italian Inst Telemed, Clin Res Unit, Varese, Italy
[4] Sotiria Hosp, Univ Dept Med 3, Hypertens Ctr STRIDE 7, Athens, Greece
关键词
Arrhythmia; Blood pressure monitoring; Self-measurement; Home blood pressure; Clinic; Stroke; CRYPTOGENIC STROKE; EUROPEAN-SOCIETY; PRIMARY-CARE; RISK-FACTORS; PREVALENCE; MANAGEMENT; ACCURACY; PREVENTION; GUIDELINES; MONITORS;
D O I
10.1016/j.ijcard.2015.10.182
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Several guidelines recommend opportunistic screening for atrial fibrillation (AF) in subjects aged >= 65 years using pulse palpation during routine blood pressure (BP) measurement. However, this method has limited diagnostic accuracy. A specific algorithm for AF detection during automated BP measurement was developed and implemented in a novel oscillometric device (Microlife WatchBP Home-A). In 2013, the UK National Institute for Health and Care Excellence (NICE) recommended this device for AF screening during routine office BP measurement in primary care in subjects >= 65 years. A review and meta-analysis of the evidence on the diagnostic accuracy of this algorithm were performed. Six studies (n=2332) investigated the accuracy of AF detection using the Microlife BP monitor and estimated a pooled sensitivity at 0.98 (95% CI 0.95, 1.00) and specificity 0.92 (0.88, 0.96). Analysis of 4 studies (n=1126) showed more readings to improve specificity (from 0.86 to 0.91) and sensitivity (from 0.97 to 0.99). Taking 3 sequential readings with at least 2 detecting AF gave the highest diagnostic accuracy. A single study (n=139) of paroxysmal AF screening with home BP monitoring (3316 days) showed sensitivity 99% and specificity 93%. Another study (n = 46) of AF screening with 24 h ambulatory BP monitoring showed that AF detected in >15% of all readings has high probability of AF diagnosis requiring confirmation by 24 h electrocardiography. AF detection with routine automated BP measurement is a reliable screening tool in the elderly, which requires confirmation by electrocardiography. Paroxysmal AF might also be detected by routine automated home or ambulatory BP monitoring. (C) 2015 The Authors. Published by Elsevier Ireland Ltd.
引用
收藏
页码:465 / 473
页数:9
相关论文
共 50 条
  • [41] Auscultatory versus oscillometric blood pressure measurement in patients with atrial fibrillation and arterial hypertension
    Selmyte-Besuspare, Aisteja
    Barysiene, Jurate
    Petrikonyte, Dovile
    Aidietis, Audrius
    Marinskis, Germanas
    Laucevicius, Aleksandras
    BMC CARDIOVASCULAR DISORDERS, 2017, 17 : 87
  • [42] Research Priorities in Atrial Fibrillation Screening A Report From a National Heart, Lung, and Blood Institute Virtual Workshop
    Benjamin, Emelia J.
    Go, Alan S.
    Desvigne-Nickens, Patrice
    Anderson, Christopher D.
    Casadei, Barbara
    Chen, Lin Y.
    Crijns, Harry J. G. M.
    Freedman, Ben
    Hills, Mellanie True
    Healey, Jeff S.
    Kamel, Hooman
    Kim, Dong-Yun
    Link, Mark S.
    Lopes, Renato D.
    Lubitz, Steven A.
    McManus, David D.
    Noseworthy, Peter A.
    Perez, Marco, V
    Piccini, Jonathan P.
    Schnabel, Renate B.
    Singer, Daniel E.
    Tieleman, Robert G.
    Turakhia, Mintu P.
    Van Gelder, Isabelle C.
    Cooper, Lawton S.
    Al-Khatib, Sana M.
    CIRCULATION, 2021, 143 (04) : 372 - 388
  • [43] Diagnostic accuracy of an oscillometric blood pressure monitor for atrial fibrillation screening
    Li, Linyi
    Bing, Sen
    Liu, Kui
    Jiang, Jun
    Zhang, Jieqiong
    Chen, Changsheng
    Wan, Yi
    BLOOD PRESSURE MONITORING, 2023, 28 (03) : 144 - 148
  • [44] Blood Pressure Control and the Reduction of Left Atrial Overload is Essential for Controlling Atrial Fibrillation
    Tanabe, Yasuko
    Kawamura, Yuichiro
    Sakamoto, Naka
    Sato, Nobuyuki
    Kikuchi, Kenjiro
    Hasebe, Naoyuki
    INTERNATIONAL HEART JOURNAL, 2009, 50 (04) : 445 - 456
  • [45] Systematic Screening for Atrial Fibrillation in the Community: Evidence and Obstacles
    Chan, Ngai-Yin
    ARRHYTHMIA & ELECTROPHYSIOLOGY REVIEW, 2018, 7 (01) : 39 - 42
  • [46] Automated office blood pressure measurement for routine clinical practice
    Myers, Martin G.
    Nelson, Mark R.
    Head, Geoffrey A.
    MEDICAL JOURNAL OF AUSTRALIA, 2012, 197 (07) : 372 - 373
  • [47] Predictive validity of automated oscillometric blood pressure monitors for screening atrial fibrillation: a systematic review and meta-analysis
    Park, Seong-Hi
    Jun, Kyung Ja
    Choi, Yun-Kyoung
    EXPERT REVIEW OF MEDICAL DEVICES, 2019, 16 (06) : 503 - 514
  • [48] Screening for atrial fibrillation: a call for evidence
    Jones, Nicholas R.
    Taylor, Clare J.
    Hobbs, F. D. Richard
    Bowman, Louise
    Casadei, Barbara
    EUROPEAN HEART JOURNAL, 2020, 41 (10) : 1075 - 1085
  • [49] The accuracy of SpaceLabs 90207 in blood pressure monitoring in patients with atrial fibrillation
    Miszkowska-Nagorna, Eliza
    Neubauer-Geryk, Jolanta
    Wolf, Jacek
    Wielicka, Melanie
    Raczak, Grzegorz
    Narkiewicz, Krzysztof
    Bieniaszewski, Leszek
    BLOOD PRESSURE, 2018, 27 (01) : 3 - 9
  • [50] Atrial Fibrillation Screening During Routine Automated Office, Home, and Ambulatory Blood Pressure Measurement: A Diagnostic Test Accuracy Systematic Review and Meta-Analysis
    Kyriakoulis, Konstantinos G.
    Kollias, Anastasios
    Menti, Ariadni
    Chardouvelis, Panagiotis
    Stergiou, George S.
    HYPERTENSION, 2024, 81 (07) : 1477 - 1488