Screening for atrial fibrillation with automated blood pressure measurement: Research evidence and practice recommendations

被引:68
作者
Verberk, Willem J. [1 ,2 ]
Omboni, Stefano [3 ]
Kollias, Anastasios [4 ]
Stergiou, George S. [4 ]
机构
[1] Maastricht Univ, Cardiovasc Res Inst Maastricht CARIM, NL-6200 MD Maastricht, Netherlands
[2] Microlife AG, Widnau, Switzerland
[3] Italian Inst Telemed, Clin Res Unit, Varese, Italy
[4] Sotiria Hosp, Univ Dept Med 3, Hypertens Ctr STRIDE 7, Athens, Greece
关键词
Arrhythmia; Blood pressure monitoring; Self-measurement; Home blood pressure; Clinic; Stroke; CRYPTOGENIC STROKE; EUROPEAN-SOCIETY; PRIMARY-CARE; RISK-FACTORS; PREVALENCE; MANAGEMENT; ACCURACY; PREVENTION; GUIDELINES; MONITORS;
D O I
10.1016/j.ijcard.2015.10.182
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Several guidelines recommend opportunistic screening for atrial fibrillation (AF) in subjects aged >= 65 years using pulse palpation during routine blood pressure (BP) measurement. However, this method has limited diagnostic accuracy. A specific algorithm for AF detection during automated BP measurement was developed and implemented in a novel oscillometric device (Microlife WatchBP Home-A). In 2013, the UK National Institute for Health and Care Excellence (NICE) recommended this device for AF screening during routine office BP measurement in primary care in subjects >= 65 years. A review and meta-analysis of the evidence on the diagnostic accuracy of this algorithm were performed. Six studies (n=2332) investigated the accuracy of AF detection using the Microlife BP monitor and estimated a pooled sensitivity at 0.98 (95% CI 0.95, 1.00) and specificity 0.92 (0.88, 0.96). Analysis of 4 studies (n=1126) showed more readings to improve specificity (from 0.86 to 0.91) and sensitivity (from 0.97 to 0.99). Taking 3 sequential readings with at least 2 detecting AF gave the highest diagnostic accuracy. A single study (n=139) of paroxysmal AF screening with home BP monitoring (3316 days) showed sensitivity 99% and specificity 93%. Another study (n = 46) of AF screening with 24 h ambulatory BP monitoring showed that AF detected in >15% of all readings has high probability of AF diagnosis requiring confirmation by 24 h electrocardiography. AF detection with routine automated BP measurement is a reliable screening tool in the elderly, which requires confirmation by electrocardiography. Paroxysmal AF might also be detected by routine automated home or ambulatory BP monitoring. (C) 2015 The Authors. Published by Elsevier Ireland Ltd.
引用
收藏
页码:465 / 473
页数:9
相关论文
共 50 条
  • [31] Understanding the Burden of Atrial Fibrillation and Importance of Screening: A Global Perspective and Recommendations for Turkey
    Aras, Dursun
    Birgul, Erdem
    Gorenek, Bulent
    Gurkas, Erdem
    Ozdemir, Atilla Ozcan
    Topcuoglu, Mehmet Akif
    Yavuz, Erdinc
    Zoghi, Mehdi
    ANATOLIAN JOURNAL OF CARDIOLOGY, 2022, 26 (09) : 673 - 684
  • [32] The effect of heart rate on blood pressure measurement in patients with atrial fibrillation: a cross-sectional study
    Zhao, Xiexiong
    Li, Jingle
    Huang, Miao
    You, Nana
    Li, Jiaying
    Li, Ruixuan
    Chen, Shunsong
    Liu, Tao
    Zeng, Jianwei
    Li, Xiaogang
    Jiang, Weihong
    HYPERTENSION RESEARCH, 2022, 45 (07) : 1183 - 1192
  • [33] Comparison of the Microlife Blood Pressure Monitor With the Omron Blood Pressure Monitor for Detecting Atrial Fibrillation
    Wiesel, Joseph
    Arbesfeld, Benjamin
    Schechter, David
    AMERICAN JOURNAL OF CARDIOLOGY, 2014, 114 (07) : 1046 - 1048
  • [34] 2021 Asia Pacific Heart Rhythm Society (APHRS) practice guidance on atrial fibrillation screening
    Chan, Ngai-Yin
    Orchard, Jessica
    Agbayani, Michael-Joseph
    Boddington, Dean
    Chao, Tze-Fan
    Johar, Sofian
    John, Bobby
    Joung, Boyoung
    Krishinan, Saravanan
    Krittayaphong, Rungroj
    Kurokawa, Sayaka
    Lau, Chu-Pak
    Lim, Toon Wei
    Pham Tran Linh
    Vien Hoang Long
    Naik, Ajay
    Okumura, Yasuo
    Sasano, Tetsuo
    Yan, Bernard
    Raharjo, Sunu Budhi
    Hanafy, Dicky Armein
    Yuniadi, Yoga
    Nwe, Nwe
    Awan, Zahid Aslam
    Huang, He
    Freedman, Ben
    JOURNAL OF ARRHYTHMIA, 2022, 38 (01) : 31 - 49
  • [35] Performance of an automated blood pressure measurement device in a stroke rehabilitation unit
    Lamarre-Cliche, Maxime
    Spacek, Elena
    Houde, Sylvie
    Furge, Priscille
    Lamarre, Celine
    Duong, Ynhu Nguyen
    Tran, Gabrielle
    Beaudoin, Nicole
    BLOOD PRESSURE MONITORING, 2021, 26 (01) : 65 - 69
  • [36] Detection of Atrial Fibrillation Using a Home Blood Pressure Monitor
    Balanis, Thomas
    Sanner, Bernd
    VASCULAR HEALTH AND RISK MANAGEMENT, 2021, 17 : 407 - 414
  • [37] Impact of Atrial Fibrillation on the Accuracy of Oscillometric Blood Pressure Monitoring
    Pagonas, Nikolaos
    Schmidt, Sven
    Eysel, Joerg
    Compton, Friederike
    Hoffmann, Clemens
    Seibert, Felix
    Hilpert, Justus
    Tschoepe, Carsten
    Zidek, Walter
    Westhoff, Timm H.
    HYPERTENSION, 2013, 62 (03) : 579 - 584
  • [38] Blood-biomarkers and devices for atrial fibrillation screening: Lessons learned from the AFRICAT (Atrial Fibrillation Research In CATalonia) study
    Pala, Elena
    Bustamante, Alejandro
    Lluis Clua-Espuny, Josep
    Acosta, Juan
    Gonzalez-Loyola, Felipe
    Dos Santos, Sara
    Ribas-Segui, Domingo
    Ballesta-Ors, Juan
    Penalba, Anna
    Giralt, Marina
    Lechuga-Duran, Inigo
    Gentille-Lorente, Delicia
    Pedrote, Alonso
    Angel Munoz, Miguel
    Montaner, Joan
    PLOS ONE, 2022, 17 (08):
  • [39] Evaluation of the performance of a machine learning based atrial fibrillation screening algorithm using an oscillometric blood pressure monitor
    Asada, Yuji
    Kudo, Yuta
    Ito, Tatsunori
    Kanda, Hiroyuki
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [40] A review of blood pressure measurement protocols among hypertension trials: implications for "evidence-based" clinical practice
    Giorgini, Paolo
    Weder, Alan B.
    Jackson, Elizabeth A.
    Brook, Robert D.
    JOURNAL OF THE AMERICAN SOCIETY OF HYPERTENSION, 2014, 8 (09) : 670 - 676