Screening for atrial fibrillation with automated blood pressure measurement: Research evidence and practice recommendations

被引:68
作者
Verberk, Willem J. [1 ,2 ]
Omboni, Stefano [3 ]
Kollias, Anastasios [4 ]
Stergiou, George S. [4 ]
机构
[1] Maastricht Univ, Cardiovasc Res Inst Maastricht CARIM, NL-6200 MD Maastricht, Netherlands
[2] Microlife AG, Widnau, Switzerland
[3] Italian Inst Telemed, Clin Res Unit, Varese, Italy
[4] Sotiria Hosp, Univ Dept Med 3, Hypertens Ctr STRIDE 7, Athens, Greece
关键词
Arrhythmia; Blood pressure monitoring; Self-measurement; Home blood pressure; Clinic; Stroke; CRYPTOGENIC STROKE; EUROPEAN-SOCIETY; PRIMARY-CARE; RISK-FACTORS; PREVALENCE; MANAGEMENT; ACCURACY; PREVENTION; GUIDELINES; MONITORS;
D O I
10.1016/j.ijcard.2015.10.182
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Several guidelines recommend opportunistic screening for atrial fibrillation (AF) in subjects aged >= 65 years using pulse palpation during routine blood pressure (BP) measurement. However, this method has limited diagnostic accuracy. A specific algorithm for AF detection during automated BP measurement was developed and implemented in a novel oscillometric device (Microlife WatchBP Home-A). In 2013, the UK National Institute for Health and Care Excellence (NICE) recommended this device for AF screening during routine office BP measurement in primary care in subjects >= 65 years. A review and meta-analysis of the evidence on the diagnostic accuracy of this algorithm were performed. Six studies (n=2332) investigated the accuracy of AF detection using the Microlife BP monitor and estimated a pooled sensitivity at 0.98 (95% CI 0.95, 1.00) and specificity 0.92 (0.88, 0.96). Analysis of 4 studies (n=1126) showed more readings to improve specificity (from 0.86 to 0.91) and sensitivity (from 0.97 to 0.99). Taking 3 sequential readings with at least 2 detecting AF gave the highest diagnostic accuracy. A single study (n=139) of paroxysmal AF screening with home BP monitoring (3316 days) showed sensitivity 99% and specificity 93%. Another study (n = 46) of AF screening with 24 h ambulatory BP monitoring showed that AF detected in >15% of all readings has high probability of AF diagnosis requiring confirmation by 24 h electrocardiography. AF detection with routine automated BP measurement is a reliable screening tool in the elderly, which requires confirmation by electrocardiography. Paroxysmal AF might also be detected by routine automated home or ambulatory BP monitoring. (C) 2015 The Authors. Published by Elsevier Ireland Ltd.
引用
收藏
页码:465 / 473
页数:9
相关论文
共 50 条
  • [1] Automated measurement of office, home and ambulatory blood pressure in atrial fibrillation
    Kollias, Anastasios
    Stergiou, George S.
    CLINICAL AND EXPERIMENTAL PHARMACOLOGY AND PHYSIOLOGY, 2014, 41 (01) : 9 - 15
  • [2] Opportunistic screening of atrial fibrillation by automatic blood pressure measurement in the community
    Omboni, Stefano
    Verberk, Willem J.
    BMJ OPEN, 2016, 6 (04):
  • [3] Screening for Atrial Fibrillation During Routine Automated Blood Pressure Measurement in General Population Aged 65 Years and Above: EMENO National Epidemiological Survey in Greece
    Menti, Ariadni
    Kalpourtzi, Natasa
    Kyriakoulis, Konstantinos G.
    Kollias, Anastasios
    Touloumi, Giota
    Stergiou, George S.
    HIGH BLOOD PRESSURE & CARDIOVASCULAR PREVENTION, 2024, 31 (06) : 649 - 655
  • [4] Accuracy of oscillometric blood pressure monitors for the detection of atrial fibrillation: a systematic review
    Verberk, Willem J.
    de Leeuw, Peter W.
    EXPERT REVIEW OF MEDICAL DEVICES, 2012, 9 (06) : 635 - 640
  • [5] Automated blood pressure measurement in atrial fibrillation: a systematic review and meta-analysis
    Stergiou, George S.
    Kollias, Anastasios
    Destounis, Antonios
    Tzamouranis, Dimitrios
    JOURNAL OF HYPERTENSION, 2012, 30 (11) : 2074 - 2082
  • [6] Automated blood pressure measurement in atrial fibrillation: validation process modification and evaluation of a novel professional device which detects atrial fibrillation and adapts its blood pressure measurement algorithm
    Stergiou, George S.
    Kyriakoulis, Konstantinos G.
    Bountzona, Ioanna
    Menti, Ariadni
    Destounis, Antonios
    Kalogeropoulos, Petros
    Kollias, Anastasios
    JOURNAL OF HYPERTENSION, 2021, 39 (04) : 614 - 620
  • [7] Blood pressure measurement in atrial fibrillation: review and meta-analysis of evidence on accuracy and clinical relevance
    Stergiou, George S.
    Kyriakoulis, Konstantinos G.
    Stambolliu, Emelina
    Destounis, Antonios
    Karpettas, Nikos
    Kalogeropoulos, Petros
    Kollias, Anastasios
    JOURNAL OF HYPERTENSION, 2019, 37 (12) : 2430 - 2441
  • [8] Screening for Atrial Fibrillation During Automatic Blood Pressure Measurements
    Lowe, Andrew
    Oh, Timothy H.
    Stewart, Ralph
    IEEE JOURNAL OF TRANSLATIONAL ENGINEERING IN HEALTH AND MEDICINE, 2018, 6
  • [9] Diagnostic Performance of Automated Blood Pressure Monitor for Detection of Atrial Fibrillation
    Othman, Rasid
    Suliman, Ayman
    Yusof, Zurkurnai
    Isa, W. Yus Haniff W.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (01)
  • [10] Comparison of automated office blood pressure measurement with 24-hour ambulatory blood pressure measurement
    Peeters, Laura E. J.
    van Oortmerssen, Julie A. E.
    Derks, Lieke H.
    den Hertog, Heleen
    Fonville, Susanne
    Verboon, Christine
    Rietdijk, Wim J. R.
    Boersma, Eric
    Koudstaal, Peter J.
    van den Meiracker, Anton H.
    Versmissen, Jorie
    BLOOD PRESSURE, 2022, 31 (01) : 9 - 18