Mechanical Ventilation Strategies in Children With Acute Lung Injury: A Survey on Stated Practice Pattern

被引:53
|
作者
Santschi, Miriam [1 ]
Randolph, Adrienne G. [2 ]
Rimensberger, Peter C. [3 ]
Jouvet, Philippe [4 ]
机构
[1] Ctr Hosp Univ Sherbrooke, Dept Pediat, Sherbrooke, PQ, Canada
[2] Boston Childrens Hosp, Dept Anesthesia, Boston, MA USA
[3] Univ Hosp Geneva, Div Pediat & Neonatal Intens Care, Dept Pediat, Geneva, Switzerland
[4] Hop St Justine, Dept Pediat, Div Pediat Crit Care Med, Montreal, PQ H3T 1C5, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
acute lung injury; child; mechanical ventilation; respiratory distress syndrome; RESPIRATORY-DISTRESS-SYNDROME; TIDAL VOLUME; OUTCOMES; FEASIBILITY; INFANTS; TRIALS;
D O I
10.1097/PCC.0b013e31828a89a2
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objectives: The aim of this survey was to determine North American and European pediatric intensivists' knowledge and stated practice in the management of children with acute respiratory distress syndrome with regard to mechanical ventilation settings; blood gas and So(2) targets; and use of adjunctive treatments at sites where actual practice had just been assessed. Design and Setting: A survey using three case scenarios to assess mechanical ventilation strategies used in children with acute respiratory distress syndrome was sent out toward the end of data collection to all centers participating in the Pediatric Acute Lung Injury Mechanical Ventilation study (59 PICUs in 12 countries). For each case scenario, intensivists were asked to report the optimal mechanical ventilation parameters; blood gas and So(2) acceptable targets; and threshold for considering high-frequency oscillatory ventilation, and other adjunctive treatments. Participants: Fifty-four pediatric intensivists, representing 47 centers from 11 countries. Interventions: None. Measurements and Main Results: Many pediatric intensivists reported using a tidal volume of 5-8 mL/kg (88-96%) and none reported using a tidal volume above 10 mL/kg. On average, the upper threshold of positive inspiratory pressure at which intensivists would consider another ventilation mode was 35 cm H2O. Permissive hypercapnia and mild hypoxemia (So(2) as low as 88%) was considered tolerable by many pediatric intensivists. Finally, a large proportion of pediatric intensivists reported they would use adjunctive treatments (nitric oxide, prone position, extracorporeal membrane oxygenation, surfactant, steroids, -agonists) if the patient's condition worsened. Conclusions: Although in theory, many pediatric intensivists agreed with adult recommendations to ventilate with lower tidal volumes and pressure limits, the Pediatric Acute Lung Injury Mechanical Ventilation data revealed that over 25% of pediatric patients with acute lung injury/acute respiratory distress syndrome at many of these practice sites were ventilated with tidal volumes above 10 mL/kg and that high positive inspiratory pressure levels (> 35 mm Hg) were often tolerated.
引用
收藏
页码:E332 / E337
页数:6
相关论文
共 50 条
  • [21] A simple classification model for hospital mortality in patients with acute lung injury managed with lung protective ventilation
    Brown, Lisa M.
    Calfee, Carolyn S.
    Matthay, Michael A.
    Brower, Roy G.
    Thompson, B. Taylor
    Checkley, William
    CRITICAL CARE MEDICINE, 2011, 39 (12) : 2645 - 2651
  • [22] A Description of Intraoperative Ventilator Management in Patients with Acute Lung Injury and the Use of Lung Protective Ventilation Strategies
    Blum, James M.
    Maile, Michael
    Park, Pauline K.
    Morris, Michelle
    Jewell, Elizabeth
    Dechert, Ronald
    Rosenberg, Andrew L.
    ANESTHESIOLOGY, 2011, 115 (01) : 75 - 82
  • [23] Fluid balance in critically ill children with acute lung injury
    Valentine, Stacey L.
    Sapru, Anil
    Higgerson, Renee A.
    Spinella, Phillip C.
    Flori, Heidi R.
    Graham, Dionne A.
    Brett, Molly
    Convery, Maureen
    Christie, LeeAnn M.
    Karamessinis, Laurie
    Randolph, Adrienne G.
    CRITICAL CARE MEDICINE, 2012, 40 (10) : 2883 - 2889
  • [24] Risk factors for underuse of lung-protective ventilation in acute lung injury
    Walkey, Allan J.
    Wiener, Renda Soylemez
    JOURNAL OF CRITICAL CARE, 2012, 27 (03)
  • [25] Lung-protective ventilation strategies in acute lung injury
    Brower, RG
    Rubenfeld, GD
    CRITICAL CARE MEDICINE, 2003, 31 (04) : S312 - S316
  • [26] Lung-protective mechanical ventilation does not protect against acute kidney injury in patients without lung injury at onset of mechanical ventilation
    Cortjens, Bart
    Royakkers, Annick A. N. M.
    Determann, Rogier M.
    van Suijlen, Jeroen D. E.
    Kamphuis, Stephan S.
    Foppen, Jannetje
    de Boer, Anita
    Wieland, Cathrien. W.
    Spronk, Peter E.
    Schultz, Marcus J.
    Bouman, Catherine S. C.
    JOURNAL OF CRITICAL CARE, 2012, 27 (03) : 261 - 267
  • [27] WNT/β-catenin signaling is modulated by mechanical ventilation in an experimental model of acute lung injury
    Villar, Jesus
    Cabrera, Nuria E.
    Casula, Milena
    Valladares, Francisco
    Flores, Carlos
    Lopez-Aguilar, Josefina
    Blanch, Lluis
    Zhang, Haibo
    Kacmarek, Robert M.
    Slutsky, Arthur S.
    INTENSIVE CARE MEDICINE, 2011, 37 (07) : 1201 - 1209
  • [28] Use of intensive care, mechanical ventilation, both, or neither by patients with acute lung injury
    Cely, Cynthia M.
    Rojas, Julian T.
    Maldonado, Diego A.
    Schein, Roland M. H.
    Quartin, Andrew A.
    CRITICAL CARE MEDICINE, 2010, 38 (04) : 1126 - 1134
  • [29] Mechanical ventilation in patients with acute brain injury
    Tomicic, Vinko F.
    Andresen, Max H.
    REVISTA MEDICA DE CHILE, 2011, 139 (03) : 382 - 390
  • [30] Association between C-reactive protein levels and outcome in acute lung injury in children
    Bruijn, M.
    Jansen, E. M.
    Klapwijk, T.
    van der Lee, J. H.
    van Rijn, R. R.
    van Woensel, J. B. M.
    Bos, A. P.
    EUROPEAN JOURNAL OF PEDIATRICS, 2013, 172 (08) : 1105 - 1110