In vitro biomechanical evaluation of sagittal split osteotomy fixation with a specifically designed miniplate

被引:21
作者
Pereira Filho, V. A. [1 ]
Iamashita, H. Y. [1 ]
Monnazzi, M. S. [1 ]
Gabrielli, M. F. R. [1 ]
Vaz, L. G. [1 ]
Passeri, L. A. [1 ]
机构
[1] Univ Estadual Paulista, Dept Diag & Oral & Maxillofacial Surg, Dent Sch Araraquara, BR-14801903 Sao Paulo, Brazil
关键词
biomechanical evaluation; sagittal split ramus osteotomy; rigid internal fixation; RIGID INTERNAL-FIXATION; RAMUS OSTEOTOMY; MANDIBULAR SETBACK; ADVANCEMENT SURGERY; PLATE FIXATION; SCREW FIXATION; STABILITY; PATTERN; SYSTEM;
D O I
10.1016/j.ijom.2012.07.008
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Recent studies have evaluated many methods of internal fixation for sagittal split ramus osteotomy (SSRO), aiming to increase stability of the bone segments while minimizing condylar displacement. The purpose of this study was to evaluate, through biomechanical testing, the stability of the fixation comparing a specially designed bone plate to other two commonly used methods. Thirty hemimandibles were separated into three equal groups. All specimens received SSRO. In Group I the osteotomies were fixed with three 15 mm bicortical positional screws in an inverted-L pattern with an insertion angle of 90 degrees. In Group II, fixation was carried out with a four-hole straight plate and four 6 mm monocortical screws. In Group III, fixation was performed with an adjustable sagittal plate and eight 6 mm monocortical screws. Hemimandibles were submitted to vertical compressive loads, by a mechanical testing unit. Averages and standard deviations were submitted to analysis of variance using the Tukey test with a 5% level of significance. Bicortical screws presented the greatest values of loading resistance. The adjustable miniplate demonstrated 60% lower resistance compared to bicortical screws. Group II presented on average 40% less resistant to the axial loading.
引用
收藏
页码:316 / 320
页数:5
相关论文
共 30 条
[1]   SKELETAL STABILITY FOLLOWING MINIPLATE FIXATION AFTER BILATERAL SAGITTAL SPLIT OSTEOTOMY FOR MANDIBULAR ADVANCEMENT [J].
ABELOOS, J ;
DECLERCQ, C ;
NEYT, L .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1993, 51 (04) :366-369
[2]   Preliminary investigation of the biomechanics of internal fixation of sagittal split osteotomies with miniplates using a newly designed in vitro testing model [J].
Armstrong, JEA ;
Lapointe, HJ ;
Hogg, NJV ;
Kwok, AD .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2001, 59 (02) :191-195
[3]   Biomechanical evaluation of a T-shaped miniplate fixation of a modified sagittal split ramus osteotomy with buccal step, a new technique for mandibular orthognathic surgery [J].
Aymach, Zaher ;
Nei, Hitoshi ;
Kawamura, Hiroshi ;
Bell, William .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2011, 111 (01) :58-63
[4]   Biomechanical Stress Distribution on Fixation Screws Used in Bilateral Sagittal Split Ramus Osteotomy: Assessment of 9 Methods via Finite Element Method [J].
Bohluli, Behnam ;
Motamedi, Mohammad Hosein Kalantar ;
Bohluli, Pedram ;
Sarkarat, Farzin ;
Moharamnejad, Nima ;
Tabrizi, Mohammad Hossein Seif .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2010, 68 (11) :2765-2769
[5]   A COMPARATIVE IN-VITRO STUDY ON FIXATION OF SAGITTAL SPLIT OSTEOTOMIES WITH WURZBURG(R) SCREWS, CHAMPY(R) MINIPLATES, AND BIOFIX(R) (BIODEGRADABLE) RODS [J].
BOUWMAN, JPB ;
TUINZING, DB ;
KOSTENSE, PJ .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1994, 23 (01) :46-48
[6]   An In Vitro Evaluation of Rigid Internal Fixation Techniques for Sagittal Split Ramus Osteotomies: Setback Surgery [J].
Brasileiro, Bernardo Ferreira ;
Grotta-Grempel, Rafael ;
Bovi Ambrosano, Glaucia Maria ;
Passeri, Luis Augusto .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2012, 70 (04) :941-951
[7]   An in Vitro Evaluation of Rigid internal Fixation Techniques for Sagittal Split Ramus Osteotomies: Advancement Surgery [J].
Brasileiro, Bernardo Ferreira ;
Grempel, Rafael Grotta ;
Bovi Ambrosano, Glaucia Maria ;
Passeri, Luis Augusto .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2009, 67 (04) :809-817
[8]   A retrospective analysis of the stability and relapse of soft and hard tissue change after bilateral sagittal split osteotomy for mandibular setback of 64 Taiwanese patients [J].
Chou, JIC ;
Fong, HJ ;
Kuang, SH ;
Lin-Yang, G ;
Hwang, FY ;
Lai, YC ;
Chang, RCS ;
Kao, SY .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2005, 63 (03) :355-361
[9]   Postoperative stability after sagittal split ramus osteotomies for a mandibular setback with monocortical plate fixation or bicortical screw fixation [J].
Chung, Il-Hyuk ;
Yoo, Chung-Kyu ;
Lee, Eun-Kyung ;
Ihm, Jong-An ;
Park, Chang-Joo ;
Lim, Ji-Sun ;
Hwang, Kyung-Gyun .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2008, 66 (03) :446-452
[10]   STABILITY OF THE MANDIBLE FOLLOWING ADVANCEMENT - A COMPARISON OF 3 POSTSURGICAL FIXATION TECHNIQUES [J].
ELLIS, E ;
REYNOLDS, S ;
CARLSON, DS .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1988, 94 (01) :38-50