Simultaneous multi-slice spin- and gradient-echo dynamic susceptibility-contrast perfusion-weighted MRI of gliomas

被引:5
作者
Han, Misung [1 ]
Yang, Baolian [2 ]
Fernandez, Brice [3 ]
Lafontaine, Marisa [1 ]
Alcaide-Leon, Paula [1 ]
Jakary, Angela [1 ]
Burns, Brian L. [4 ]
Morrison, Melanie A. [1 ]
Villanueva-Meyer, Javier E. [1 ]
Chang, Susan M. [5 ]
Banerjee, Suchandrima [4 ]
Lupo, Janine M. [1 ,6 ,7 ]
机构
[1] Univ Calif San Francisco, Dept Radiol & Biomed Imaging, 1700 4th St,Suite 201, San Francisco, CA 94158 USA
[2] GE Healthcare, Applicat & Workflow, Waukesha, WI USA
[3] GE Healthcare, Applicat & Workflow, Orsay, France
[4] GE Healthcare, Applicat & Workflow, Menlo Pk, CA USA
[5] Univ Calif San Francisco, Dept Neurol Surg, San Francisco, CA 94158 USA
[6] Univ Calif San Francisco, UCSF UC Berkeley Grad Program Bioengn, San Francisco, CA 94158 USA
[7] Univ Calif Berkeley, San Francisco, CA USA
关键词
dynamic susceptibility-contrast imaging; gliomas; perfusion; simultaneous multi-slice acceleration; spin-echo and gradient-echo EPI; CEREBRAL BLOOD-VOLUME; BRAIN-TUMOR; MAGNETIC-SUSCEPTIBILITY; MAPS; GRADE; SIGNAL; OPTIMIZATION; REGISTRATION; VASCULARITY; RECURRENCE;
D O I
10.1002/nbm.4399
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Although combined spin- and gradient-echo (SAGE) dynamic susceptibility-contrast (DSC) MRI can provide perfusion quantification that is sensitive to both macrovessels and microvessels while correcting forT(1)-shortening effects, spatial coverage is often limited in order to maintain a high temporal resolution for DSC quantification. In this work, we combined a SAGE echo-planar imaging (EPI) sequence with simultaneous multi-slice (SMS) excitation and blipped controlled aliasing in parallel imaging (blipped CAIPI) at 3 T to achieve both high temporal resolution and whole brain coverage. Two protocols using this sequence with multi-band (MB) acceleration factors of 2 and 3 were evaluated in 20 patients with treated gliomas to determine the optimal scan parameters for clinical use. Delta R-2*(t) and Delta R-2(t) curves were derived to calculate dynamic signal-to-noise ratio (dSNR), Delta R-2*- and Delta R-2-based relative cerebral blood volume (rCBV), and mean vessel diameter (mVD) for each voxel. The resulting SAGE DSC images acquired using MB acceleration of 3 versus 2 appeared visually similar in terms of image distortion and contrast. The difference in the mean dSNR from normal-appearing white matter (NAWM) and that in the mean dSNR between NAWM and normal-appearing gray matter were not statistically significant between the two protocols. Delta R-2*- and Delta R-2-rCBV maps and mVD maps provided unique contrast and spatial heterogeneity within tumors.
引用
收藏
页数:12
相关论文
共 55 条
  • [1] CEREBRAL BLOOD-VOLUME MAPS OF GLIOMAS - COMPARISON WITH TUMOR GRADE AND HISTOLOGIC-FINDINGS
    ARONEN, HJ
    GAZIT, IE
    LOUIS, DN
    BUCHBINDER, BR
    PARDO, FS
    WEISSKOFF, RM
    HARSH, GR
    COSGROVE, GR
    HALPERN, EF
    HOCHBERG, FH
    ROSEN, BR
    [J]. RADIOLOGY, 1994, 191 (01) : 41 - 51
  • [2] Arpinar VE, 2019, P 27 ANN M ISMRM MON, P3949
  • [3] Differentiation of Recurrent Glioblastoma Multiforme from Radiation Necrosis after External Beam Radiation Therapy with Dynamic Susceptibility-weighted Contrast-enhanced Perfusion MR Imaging
    Barajas, Ramon F., Jr.
    Chang, Jamie S.
    Segal, Mark R.
    Parsa, Andrew T.
    McDermott, Michael W.
    Berger, Mitchel S.
    Cha, Soonmee
    [J]. RADIOLOGY, 2009, 253 (02) : 486 - 496
  • [4] Accuracy of gamma-variate fits to concentration-time curves from dynamic susceptibility-contrast enhanced MRI: Influence of time resolution, maximal signal drop and signal-to-noise
    Benner, T
    Heiland, S
    Erb, G
    Forsting, M
    Sartor, K
    [J]. MAGNETIC RESONANCE IMAGING, 1997, 15 (03) : 307 - 317
  • [5] Boxerman JL, 2006, AM J NEURORADIOL, V27, P859
  • [6] Signal-to-noise analysis of cerebral blood volume maps from dynamic NMR imaging studies
    Boxerman, JL
    Rosen, BR
    Weisskoff, RM
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (03): : 528 - 537
  • [7] MR CONTRAST DUE TO INTRAVASCULAR MAGNETIC-SUSCEPTIBILITY PERTURBATIONS
    BOXERMAN, JL
    HAMBERG, LM
    ROSEN, BR
    WEISSKOFF, RM
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (04) : 555 - 566
  • [8] Comparison of reconstruction accuracy and efficiency among autocalibrating data-driven parallel imaging methods
    Brau, Anja C. S.
    Beatty, Philip J.
    Skare, Stefan
    Bammer, Roland
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2008, 59 (02) : 382 - 395
  • [9] Controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) for multi-slice imaging
    Breuer, FA
    Blaimer, M
    Heidemann, RM
    Mueller, MF
    Griswold, MA
    Jakob, PM
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (03) : 684 - 691
  • [10] Improved Spatiotemporal Resolution of Dynamic Susceptibility Contrast Perfusion MRI in Brain Tumors Using Simultaneous Multi-Slice Echo-Planar Imaging
    Chakhoyan, A.
    Leu, K.
    Pope, W. B.
    Cloughesy, T. F.
    Ellingson, B. M.
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2018, 39 (01) : 43 - 45