Identification of proteins in complexes by solid phase microextraction multistep elution capillary electrophoresis tandem mass spectrometry

被引:128
作者
Tong, W [1 ]
Link, A [1 ]
Eng, JK [1 ]
Yates, JR [1 ]
机构
[1] Univ Washington, Dept Mol Biotechnol, Seattle, WA 98195 USA
关键词
D O I
10.1021/ac9901182
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A method to directly identify proteins in complex mixtures by solid-phase microextraction (micro-SPE)/multistep elution/capillary electrophoresis (CE)/tandem mass spectrometry (MS/MS) is described. A sheathless liquid-metal junction interface is used to interface CE and electrospray ionization MS/MS. A subfemtomole detection limit is achieved for protein identification through database searching using MS/MS data. The SPE serves as a semiseparation dimension using an organic-phase step-elution gradient in combination with the second separation dimension for increased resolving power of complex peptide mixtures. This approach improves the concentration detection limit for CE and allows more proteins in complex mixtures to be identified. A 75-protein complex from yeast ribosome is analyzed using this method and 80-90% of the proteins in the complex can be identified by searching the database using the MS/MS data from a complete analysis. This multidimensional CE/MS/MS methodology provides an alternative to multidimensional liquid chromatography/MS/MS for direct identification of small amounts of protein in mixtures.
引用
收藏
页码:2270 / 2278
页数:9
相关论文
共 33 条
[1]  
Bateman KP, 1997, RAPID COMMUN MASS SP, V11, P307
[2]  
BATTANER E, 1971, METHOD ENZYMOL, V20, P446
[3]   HIGH-RESOLUTION MINI-2-DIMENSIONAL GEL-ELECTROPHORESIS OF YEAST RIBOSOMAL-PROTEINS - A STANDARD NOMENCLATURE FOR YEAST RIBOSOMAL-PROTEINS [J].
BOLLEN, GHPM ;
MAGER, WH ;
PLANTA, RJ .
MOLECULAR BIOLOGY REPORTS, 1981, 8 (01) :37-44
[4]  
BRADFORD MM, 1976, ANAL BIOCHEM, V72, P248, DOI 10.1016/0003-2697(76)90527-3
[5]   PERFORMANCE OF CARBOHYDRATE-MODIFIED FUSED-SILICA CAPILLARIES FOR THE SEPARATION OF PROTEINS BY ZONE ELECTROPHORESIS [J].
BRUIN, GJM ;
HUISDEN, R ;
KRAAK, JC ;
POPPE, H .
JOURNAL OF CHROMATOGRAPHY, 1989, 480 :339-349
[6]   LOW-FLOW HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY SOLVENT DELIVERY SYSTEM DESIGNED FOR TANDEM CAPILLARY LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
DAVIS, MT ;
STAHL, DC ;
LEE, TD .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1995, 6 (07) :571-577
[7]   Rapid protein identification using a microscale electrospray LC/MS system on an ion trap mass spectrometer [J].
Davis, MT ;
Lee, TD .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1998, 9 (03) :194-201
[8]   SWITCHING VALVE WITH INTERNAL MICRO PRECOLUMN FOR ONLINE SAMPLE ENRICHMENT IN CAPILLARY ZONE ELECTROPHORESIS [J].
DEBETS, AJJ ;
MAZEREEUW, M ;
VOOGT, WH ;
VANIPEREN, DJ ;
LINGEMAN, H ;
HUPE, KP ;
BRINKMAN, UAT .
JOURNAL OF CHROMATOGRAPHY, 1992, 608 (1-2) :151-158
[9]   AN APPROACH TO CORRELATE TANDEM MASS-SPECTRAL DATA OF PEPTIDES WITH AMINO-ACID-SEQUENCES IN A PROTEIN DATABASE [J].
ENG, JK ;
MCCORMACK, AL ;
YATES, JR .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1994, 5 (11) :976-989
[10]   Protein identification by capillary zone electrophoresis/microelectrospray ionization-tandem mass spectrometry at the subfemtomole level [J].
Figeys, D ;
vanOostveen, I ;
Ducret, A ;
Aebersold, R .
ANALYTICAL CHEMISTRY, 1996, 68 (11) :1822-1828