Embozene™ microspheres induced nonreperfused myocardial infarction in an experimental swine model

被引:8
作者
Varga-Szemes, Akos [1 ,2 ,3 ]
Kiss, Pal [2 ]
Brott, Brigitta C. [4 ]
Wang, Dezhi [5 ]
Simor, Tamas [1 ,2 ,3 ]
Elgavish, Gabriel A. [1 ,2 ,4 ]
机构
[1] Univ Alabama Birmingham, Dept Biochem & Mol Genet, Birmingham, AL 35294 USA
[2] Elgavish Paramagnet Inc, Birmingham, AL USA
[3] Univ Pecs, Sch Med, Inst Heart, Pecs, Hungary
[4] Univ Alabama Birmingham, Dept Med, Div Cardiovasc Dis, Birmingham, AL 35294 USA
[5] Univ Alabama Birmingham, Dept Pathol, Ctr Metab Bone Dis, Birmingham, AL 35294 USA
基金
美国国家卫生研究院;
关键词
myocardial infarct model; microsphere embolization; magnetic resonance imaging; CORONARY; PIG; OCCLUSION; REPERFUSION; INJECTION; HEART;
D O I
10.1002/ccd.24418
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives To develop a magnetic resonance imaging (MRI) compatible, percutaneous technique for the generation of nonreperfused myocardial infarct (MI). Background Modeling nontreated MI has major importance in the development and preclinical testing of new therapeutic strategies for patients missing the time window suitable for revascularization following MI. Methods In 31 male swine, nonreperfused MI was generated by permanent occlusion of either the LAD or LCX coronary artery using 900 m Embozene microspheres. Animals were monitored for 90 min postocclusion. Surviving animals were followed up for 2 (n = 6), 4 (n = 6), 14 (n = 6), or 56 (n = 6) days. At the end of the planned study session, contrast enhanced MRI, triphenyl-tetrazolium-chloride staining, and microscopic histopathology were carried out. Results The mortality rate in this study was 22.6%. Intraoperative arrhythmias occurred in 14 cases: premature ventricular complexes with (5) or without (3) ventricular tachycardia, 2nd degree atrio-ventricular block (1), and ventricular fibrillation (6). MRI, TTC, and histology confirmed the existence of MI in every case. Macroscopic pathology showed that the microspheres caused a practically total occlusion at the epicardial level of the coronary artery. Multiple infarcts were detected in one case, probably due to unintentional reflux of the microspheres. Microspheres retained in the coronary arteries did not cause any MRI artifact. Conclusions The generation of nonreperfused MI is feasible by percutaneous injection of Embozene into the coronary artery system. The MI model thus obtained is suitable for the purposes of MRI experiments. (c) 2012 Wiley Periodicals, Inc.
引用
收藏
页码:689 / 697
页数:9
相关论文
共 20 条
  • [1] Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart - A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association
    Cerqueira, MD
    Weissman, NJ
    Dilsizian, V
    Jacobs, AK
    Kaul, S
    Laskey, WK
    Pennell, DJ
    Rumberger, JA
    Ryan, T
    Verani, MS
    [J]. CIRCULATION, 2002, 105 (04) : 539 - 542
  • [2] Edwards M B, 2000, J Magn Reson Imaging, V12, P363, DOI 10.1002/1522-2586(200008)12:2<363::AID-JMRI21>3.0.CO
  • [3] 2-3
  • [4] A CLOSED-CHEST PIG MODEL OF SUSTAINED VENTRICULAR-TACHYCARDIA
    ELDAR, M
    OHAD, D
    BOR, A
    VARDABLOOM, N
    SWANSON, DK
    BATTLER, A
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1994, 17 (10): : 1603 - 1609
  • [5] MYOCARDIAL REPERFUSION IN THE PIG-HEART MODEL - INFARCT SIZE AND DURATION OF CORONARY-OCCLUSION
    GARCIADORADO, D
    THEROUX, P
    ELIZAGA, J
    GALINANES, M
    SOLARES, J
    RIESGO, M
    GOMEZ, MJ
    GARCIADORADO, A
    AVILES, FF
    [J]. CARDIOVASCULAR RESEARCH, 1987, 21 (07) : 537 - 544
  • [6] A NEW TECHNIQUE FOR PRODUCING MYOCARDIAL-INFARCTION USING CORONARY-ARTERY BALLOON OCCLUSION
    GARNER, D
    GINZTON, LE
    JAGELS, G
    LAKS, MM
    [J]. CARDIOVASCULAR RESEARCH, 1988, 22 (01) : 42 - 46
  • [7] Endovascular Techniques for Treatment of Carotid-Cavernous Fistula
    Gemmete, Joseph J.
    Ansari, Sameer A.
    Gandhi, Dheeraj M.
    [J]. JOURNAL OF NEURO-OPHTHALMOLOGY, 2009, 29 (01) : 62 - 71
  • [8] INTRACORONARY ETHANOL ABLATION IN SWINE - EFFECTS OF ETHANOL CONCENTRATION ON LESION FORMATION AND RESPONSE TO PROGRAMMED VENTRICULAR STIMULATION
    HAINES, DE
    WHAYNE, JG
    DIMARCO, JP
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 1994, 5 (05) : 422 - 431
  • [9] CORONARY-ARTERY EMBOLIZATION IN CLOSED-CHEST CANINES USING FLEXIBLE RADIOPAQUE PLUGS
    HERR, MD
    MCINERNEY, JJ
    COPENHAVER, GL
    MORRIS, DL
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1988, 64 (05) : 2236 - 2239
  • [10] MORPHOMETRY OF PIG CORONARY ARTERIAL TREES
    KASSAB, GS
    RIDER, CA
    TANG, NJ
    FUNG, YCB
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY, 1993, 265 (01): : H350 - H365