Investigating Lubrication Properties Using Pulse-Echo Ultrasound Technique

被引:0
|
作者
Imad, Fadi [1 ]
Nagi, Farrukh [1 ]
Ahmed, Syed Khaleel [1 ]
机构
[1] Univ Tenaga Nas, Jalan IKRAM UNITEN, Coll Engn, Selangor 43000, Kajang, Malaysia
来源
2012 IEEE INTERNATIONAL CONFERENCE ON CONTROL SYSTEM, COMPUTING AND ENGINEERING (ICCSCE 2012) | 2012年
关键词
Grease; condition; Ultrasound; pulse-echo; wavelet;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This paper presents a technique that utilizes ultrasonic puls-echo method to determine insufficient lubrication in static mechanical components and assemblies. Due to prolong static in-operation of such systems as spring actuated circuit breakers (CB) the lubricants/grease in the actuation mechanism dries up resulting in sluggish response. Since these systems remain static they don't emit any acoustic signals. Therefore active pulse-echo ultrasonic testing method is proposed to determine the lubricant condition. In the proposed method wavelet analysis is used to de-noise the signal and extract data about lubricant condition. The extracted features from different samples is be used to develop a fuzzy inference system to define the lubricant condition.
引用
收藏
页码:166 / 170
页数:5
相关论文
共 50 条
  • [21] Improvement in the Quantification of Foreign Object Defects in Carbon Fiber Laminates Using Immersion Pulse-Echo Ultrasound
    Blackman, Nathaniel J.
    Jack, David A.
    Blandford, Benjamin M.
    MATERIALS, 2021, 14 (11)
  • [22] Toward Speed-of-Sound Anisotropy Quantification in Muscle With Pulse-Echo Ultrasound
    Korta Martiartu, Naiara
    Simute, Saule
    Jaeger, Michael
    Frauenfelder, Thomas
    Rominger, Marga B.
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2022, 69 (08) : 2499 - 2511
  • [23] Combined photoacoustic, pulse-echo laser ultrasound, and speed-of-sound imaging using integrating optical detection
    Wurzinger, Gerhild
    Nuster, Robert
    Paltauf, Guenther
    JOURNAL OF BIOMEDICAL OPTICS, 2016, 21 (08)
  • [24] Pulse-echo ultrasound method for detection of post-menopausal women with osteoporotic BMD
    J. P. Karjalainen
    O. Riekkinen
    H. Kröger
    Osteoporosis International, 2018, 29 : 1193 - 1199
  • [25] Critical evaluation of pulse-echo ultrasonic test method for the determination of setting and mechanical properties of acrylic bone cement: Influence of mixing technique
    Hagan, Christopher P.
    Orr, John F.
    Mitchell, Christina A.
    Dunne, Nicholas J.
    ULTRASONICS, 2015, 56 : 279 - 286
  • [26] Plane Wave Pulse-Echo Ultrasound Diffraction Tomography with a Fixed Linear Transducer Array
    Schiffner, Martin F.
    Schmitz, Georg
    ACOUSTICAL IMAGING, VOL 31, 2012, 31 : 19 - 30
  • [27] Pulse-echo ultrasound method for detection of post-menopausal women with osteoporotic BMD
    Karjalainen, J. P.
    Riekkinen, O.
    Kroger, H.
    OSTEOPOROSIS INTERNATIONAL, 2018, 29 (05) : 1193 - 1199
  • [28] Accurate Step-FMCW Ultrasound Ranging and Comparison with Pulse-Echo Signaling Methods
    Natarajan, Shyam
    Singh, Rahul S.
    Lee, Michael
    Cox, Brian P.
    Culjat, Martin O.
    Grundfest, Warren S.
    Lee, Hua
    MEDICAL IMAGING 2010: ULTRASONIC IMAGING, TOMOGRAPHY, AND THERAPY, 2010, 7629
  • [29] Design and modeling of signals by using wavelets for the pulse-echo NDT approaches
    Shi, LH
    Chen, B
    Gao, C
    Zhou, BH
    NONDESTRUCTIVE EVALUATION OF MATERIALS AND COMPOSITES V, 2001, 4336 : 146 - 153
  • [30] Study on freezing characteristics of the surface water film over glaze ice by using an ultrasonic pulse-echo technique
    Wang, Yuan
    Wang, Yan
    Li, Wen
    Wu, Dawei
    Zhao, Ning
    Zhu, Chunling
    ULTRASONICS, 2022, 126