A Multiplanar Radiography Method for Assessing Cup Orientation in Total Hip Arthroplasty

被引:7
作者
Amiri, Shahram [1 ]
Masri, Bassam A. [2 ]
Garbuz, Donald [2 ]
Anglin, Carolyn [3 ]
Wilson, David R. [1 ]
机构
[1] Vancouver Coastal Hlth Res Inst, Ctr Hip Hlth & Mobil, Dept Orthopaed, Vancouver, BC, Canada
[2] Univ British Columbia, Dept Orthopaed, Vancouver, BC V5Z 1M9, Canada
[3] Univ Calgary, Dept Civil Engn, McCaig Inst Bone & Joint Hlth, Calgary, AB T2N 1N4, Canada
来源
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME | 2012年 / 134卷 / 10期
关键词
ACETABULAR CUP; JOHN CHARNLEY; CT; COMPONENT; PLACEMENT; REPLACEMENT; NAVIGATION; INSERTION; ACCURACY; POSITION;
D O I
10.1115/1.4007664
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Correct orientation of the acetabular cup considering patient-specific functional pelvic angles is an important factor for improving outcomes and avoiding complications after total hip arthroplasty. This study introduces a new, noninvasive radiographic tool for accurately determining a patient's specific pelvic tilt angle preoperatively, as well as accurately assessing acetabular cup orientation with respect to bony landmarks intraoperatively and postoperatively. The method was validated by imaging a bone replica model of the pelvis with implanted hip components, in comparison to digitized references, and verified with a cadaveric specimen. Pelvic tilt was measured with an accuracy of 0.1 deg and SD of 0.4 deg. Operative cup inclination and anteversion showed accuracies of 0.6 deg and 2.5 deg, with SD of 0.4 deg and 0.6 deg, respectively; these could be improved further by subtracting systematic bias. The method shows accuracy advantages over existing radiographic and fluoroscopic methods and exposes the subjects to a lower radiation dose compared to the similar computed tomography methods. These results suggest that the proposed method is feasible for assessing cup placement with reference to the functional and anatomical references. Furthermore, the ability to reference the same bony landmarks preoperatively, intraoperatively, and postoperatively has important research and clinical advantages. [DOI: 10.1115/1.4007664]
引用
收藏
页数:10
相关论文
共 50 条
[41]   Does Functional Cup Orientation Change at Minimum of 10 Years After Primary Total Hip Arthroplasty? [J].
Cotter, Brendan D. ;
Innmann, Moritz M. ;
Dobransky, Johanna S. ;
Merle, Christian ;
Beaule, Paul E. ;
Grammatopoulos, George .
JOURNAL OF ARTHROPLASTY, 2020, 35 (09) :2507-2512
[42]   Effect of Cementless Acetabular Component Orientation, Position, and Containment in Total Hip Arthroplasty for Congenital Hip Disease [J].
Georgiades, George ;
Babis, George C. ;
Kourlaba, Georgia ;
Hartofilakidis, George .
JOURNAL OF ARTHROPLASTY, 2010, 25 (07) :1143-1150
[43]   Sagittal Imbalance Does Not Influence Cup Anteversion in Total Hip Arthroplasty Dislocations [J].
Haws, Brittany E. ;
Khechen, Benjamin ;
Patel, Dil, V ;
Louie, Philip K. ;
Iyer, Sravisht ;
Cardinal, Kaitlyn L. ;
Guntin, Jordan A. ;
Singh, Kern .
CLINICAL SPINE SURGERY, 2019, 32 (01) :E31-E36
[44]   Does Intraoperative Fluoroscopy Improve Component Positioning in Total Hip Arthroplasty? [J].
Tischler, Eric H. ;
Orozco, Fabio ;
Aggarwal, Vinay K. ;
Pacheco, Haroldo ;
Post, Zachary ;
Ong, Alvin .
ORTHOPEDICS, 2015, 38 (01) :E1-E6
[45]   Radiographic Underestimation of In Vivo Cup Coverage Provided by Total Hip Arthroplasty for Dysplasia [J].
Nie, Yong ;
Wang, HaoYang ;
Huang, ZeYu ;
Shen, Bin ;
Kraus, Virginia Byers ;
Zhou, ZongKe .
ORTHOPEDICS, 2018, 41 (01) :E46-E51
[46]   Adjustment of Acetabular Cup Inclination Assisted by Smartphone during Revision Total Hip Arthroplasty: Surgical Technique and Report of Four Cases [J].
Khalifa, Ahmed A. ;
Adam, Mahmoud Faisa ;
Mahran, Mohamed A. .
REVISTA BRASILEIRA DE ORTOPEDIA, 2025, 60 (01) :14-14
[47]   A Comparison Between Imageless Navigated and Manual Freehand Technique Acetabular Cup Placement in Total Hip Arthroplasty [J].
Hohmann, Erik ;
Bryant, Adam ;
Tetsworth, Kevin .
JOURNAL OF ARTHROPLASTY, 2011, 26 (07) :1078-1082
[48]   Total Hip Arthroplasty with Robotic Arm Assistance for Precise Cup Positioning: A Case-Control Study [J].
Guo, Dong-hui ;
Li, Xiao-ming ;
Ma, Shi-qiang ;
Zhao, Yun-chao ;
Qi, Chao ;
Xue, Yuan .
ORTHOPAEDIC SURGERY, 2022, 14 (07) :1498-1505
[49]   Acetabular cup positioning in primary routine total hip arthroplasty-a review of current concepts and technologies [J].
Sathikumar, Aravind Sai ;
Jacob, George ;
Thomas, Appu Benny ;
Varghese, Jacob ;
Menon, Venugopal .
ARTHROPLASTY, 2023, 5 (01)
[50]   A Pilot Study of Augmented Reality Technology Applied to the Acetabular Cup Placement During Total Hip Arthroplasty [J].
Ogawa, Hiroyuki ;
Hasegawa, Seiichirou ;
Tsukada, Sachiyuki ;
Matsubara, Masaaki .
JOURNAL OF ARTHROPLASTY, 2018, 33 (06) :1833-1837