The effect of labeling photo documents in wrist arthroscopies on intra- and interobserver reliability

被引:13
|
作者
Loew, Steffen [1 ]
Herold, Dirk [1 ]
Muehldorfer-Fodor, Marion [2 ]
Pillukat, Thomas [2 ]
机构
[1] Caritas Krankenhaus, Sect Hand Surg, Clin Orthopaed & Trauma Surg, D-97980 Bad Mergentheim, Germany
[2] Rhon Klinikum AG, Clin Hand Surg, Bad Neustadt an der Saale, Germany
关键词
Interobserver; Intraobserver; Labeling; Reliability; Photo documents; Wrist arthroscopy; TRIANGULAR FIBROCARTILAGE COMPLEX; CLASSIFICATION; LESIONS; AGREEMENT; REPAIR; TEARS;
D O I
10.1007/s00402-012-1612-6
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction The reproducibility of diagnoses based on photo documents in wrist arthroscopies is limited and is expected to improve if the photos are labeled with illustrated structures. Aim The purpose of this study was to determine the effect of labeling photo documents on intra- and interobserver agreement and reliability of standard photo documentation in wrist arthroscopies. Materials and methods Digital photographs of 50 arthroscopies were re-evaluated by the surgeon as well as by two independent hand surgeons. First the photos were presented unlabeled in a random order, then the labeled photos in a uniform order. Intra- and interobserver reliability was assessed, and expressed by kappa coefficients. Results Overall, labeling the photos resulted in a slight improvement in intra- and interobserver reliability (0.573/0.444/0.420 vs. 0.518/0.412/0.212). The time needed to conceive the photo documents, however, was shortened when the photos were labeled. The cartilage status was assessed considerably more accurately if the photos were labeled (0.556/0.560/0.422 vs. 0.459/0.326/0.240; t test: P = 0.094). Whereas the SL ligament was assessed more accurately according to labeled photos (P = 0.100), the agreement rates for the assessment of other ligament structures (TFCC, LT and radiopalmar ligaments) were not substantially affected by labeling the photos. On re-evaluation of the unlabeled as well as the labeled photos, intraobserver reliability was better than interobserver reliability (0.518 vs. 0.412/0.212 and 0.573 vs. 0.444/0.420). Conclusion Labeling simplifies but does not necessarily improve the reproducibility of photo documents in wrist arthroscopies. To display the cartilage status and the integrity of the SL ligament, digital photo documents should be labeled with the illustrated structure or joint surface.
引用
收藏
页码:1813 / 1818
页数:6
相关论文
共 50 条
  • [41] Intra- and interobserver reliability of gray scale/dynamic range evaluation of ultrasonography using a standardized phantom
    Lee, Song
    Choi, Joon-Il
    Park, Michael Yong
    Yeo, Dong Myung
    Byun, Jae Young
    Jung, Seung Eun
    Rha, Sung Eun
    Oh, Soon Nam
    Lee, Young Joon
    ULTRASONOGRAPHY, 2014, 33 (02) : 91 - 97
  • [42] A classification-system improves the intra- and interobserver reliability of radiographic diagnosis of "pistol-grip-deformity"
    Ipach, Ingmar
    Arlt, Eva-Maria
    Mittag, Falk
    Kunze, Beate
    Wolf, Petra
    Kluba, Torsten
    HIP INTERNATIONAL, 2011, 21 (06) : 732 - 739
  • [43] Ultrasound measurements of the normal peroneal tubercle: validation of the normal anatomical measurements and evaluation of the intra- and interobserver reliability
    Bosmans, Frederik
    Logghe, Tine
    Vanhoenacker, Filip
    POLISH JOURNAL OF RADIOLOGY, 2024, 89 : e187 - e195
  • [44] Intra- and Interobserver Reliability of Yamaguchi's Method for the Assessment of First Metatarsal Pronation in Hallux Valgus Deformity
    Del Vecchio, Jorge Javier
    Dealbera, Eric Daniel
    Brue, Julieta
    Ghioldi, Mauricio Esteban
    Chemes, Lucas Nicolas
    Abdelatif, Nasef M. N.
    Chan, Debora
    JOURNAL OF FOOT & ANKLE SURGERY, 2023, 62 (03): : 432 - 436
  • [45] Intra- and interobserver reliability of two classification systems for posterolateral tibial plateau fractures in the setting of an ACL rupture
    Moreels, Robin
    Vervaecke, Alexander J.
    Van Haver, Annemieke
    Heylen, Steven
    JOURNAL OF ORTHOPAEDICS, 2024, 51 : 21 - 26
  • [46] Three-dimensional Doppler evaluation of single spherical samples from the placenta: intra- and interobserver reliability
    Martins, W. P.
    Lima, J. C.
    Welsh, A. W.
    Araujo, E., Jr.
    Miyague, A. H.
    Filho, F. M.
    Raine-Fenning, N. J.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2012, 40 (02) : 200 - 206
  • [47] Intra- and interobserver reliability of levator ani muscle biometry and avulsion using three-dimensional endovaginal ultrasonography
    van Delft, K.
    Shobeiri, S. A.
    Thakar, R.
    Schwertner-Tiepelmann, N.
    Sultan, A. H.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2014, 43 (02) : 202 - 209
  • [48] Intra- and interobserver reliability of a modified distraction test based on digital images to assess lower eyelid horizontal tension
    Almeida Stuchi, Daniella de Paiva
    Rossato, Juliana
    de Lima Bocaccio, Francisco Jose
    Procianoy, Fernando
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2020, 83 (02) : 127 - 131
  • [49] Intra- and interobserver reliability of lens equatorial length measurement using 35-MHz ultrasound biomicroscopy in dogs with cataract
    Barbe, Charlotte
    Harran, Nathaniel
    Goulle, Frederic
    VETERINARY OPHTHALMOLOGY, 2017, 20 (04) : 329 - 334
  • [50] Intra- and interobserver reliability for predicting hip preservation versus hip arthroplasty utilizing plain radiographs with comparison of surgeon specialization
    Schultz, Kyle
    Osborne, Jeff
    Nelson, Karen
    Potini, Vishnu
    Chen, Chaoyang
    Aljuni, Andrew
    Bedi, Asheesh
    Bookout, James
    Yusaf, Michael
    Bishai, Shariff K.
    JOURNAL OF HIP PRESERVATION SURGERY, 2020, 7 (01): : 70 - 76