The effect of labeling photo documents in wrist arthroscopies on intra- and interobserver reliability

被引:13
|
作者
Loew, Steffen [1 ]
Herold, Dirk [1 ]
Muehldorfer-Fodor, Marion [2 ]
Pillukat, Thomas [2 ]
机构
[1] Caritas Krankenhaus, Sect Hand Surg, Clin Orthopaed & Trauma Surg, D-97980 Bad Mergentheim, Germany
[2] Rhon Klinikum AG, Clin Hand Surg, Bad Neustadt an der Saale, Germany
关键词
Interobserver; Intraobserver; Labeling; Reliability; Photo documents; Wrist arthroscopy; TRIANGULAR FIBROCARTILAGE COMPLEX; CLASSIFICATION; LESIONS; AGREEMENT; REPAIR; TEARS;
D O I
10.1007/s00402-012-1612-6
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction The reproducibility of diagnoses based on photo documents in wrist arthroscopies is limited and is expected to improve if the photos are labeled with illustrated structures. Aim The purpose of this study was to determine the effect of labeling photo documents on intra- and interobserver agreement and reliability of standard photo documentation in wrist arthroscopies. Materials and methods Digital photographs of 50 arthroscopies were re-evaluated by the surgeon as well as by two independent hand surgeons. First the photos were presented unlabeled in a random order, then the labeled photos in a uniform order. Intra- and interobserver reliability was assessed, and expressed by kappa coefficients. Results Overall, labeling the photos resulted in a slight improvement in intra- and interobserver reliability (0.573/0.444/0.420 vs. 0.518/0.412/0.212). The time needed to conceive the photo documents, however, was shortened when the photos were labeled. The cartilage status was assessed considerably more accurately if the photos were labeled (0.556/0.560/0.422 vs. 0.459/0.326/0.240; t test: P = 0.094). Whereas the SL ligament was assessed more accurately according to labeled photos (P = 0.100), the agreement rates for the assessment of other ligament structures (TFCC, LT and radiopalmar ligaments) were not substantially affected by labeling the photos. On re-evaluation of the unlabeled as well as the labeled photos, intraobserver reliability was better than interobserver reliability (0.518 vs. 0.412/0.212 and 0.573 vs. 0.444/0.420). Conclusion Labeling simplifies but does not necessarily improve the reproducibility of photo documents in wrist arthroscopies. To display the cartilage status and the integrity of the SL ligament, digital photo documents should be labeled with the illustrated structure or joint surface.
引用
收藏
页码:1813 / 1818
页数:6
相关论文
共 38 条
  • [31] Intra- and interobserver reliability of the Spinal Instability Neoplastic Score system for instability in spine metastases: a systematic review and meta-analysis
    Pennington, Zach
    Ahmed, A. Karim
    Cottrill, Ethan
    Westbroek, Erick M.
    Goodwin, Matthew L.
    Sciubba, Daniel M.
    ANNALS OF TRANSLATIONAL MEDICINE, 2019, 7 (10)
  • [32] Intra- and interobserver reliability and agreement in three-dimensional computed tomography measurements of component positions after total knee arthroplasty
    Yoshino, Kensuke
    Hagiwara, Shigeo
    Nakamura, Junichi
    Tsukeoka, Tadashi
    Tsuneizumi, Yoshikazu
    Ohtori, Seiji
    KNEE, 2019, 26 (05): : 1102 - 1110
  • [33] Effect of merging levels of locomotion scores for dairy cows on intra- and interrater reliability and agreement
    Schlageter-Tello, Andres
    Bokkers, Eddie A. M.
    Koerkamp, Peter W. G. Groot
    Van Hertem, Tom
    Viazzi, Stefano
    Romanini, Carlos E. B.
    Halachmi, Ilan
    Bahr, Claudia
    Berckmans, Daniel
    Lokhorst, Kees
    JOURNAL OF DAIRY SCIENCE, 2014, 97 (09) : 5533 - 5542
  • [34] EVALUATING THE INTRA- AND INTEROBSERVER RELIABILITY OF THREE-DIMENSIONAL ULTRASOUND AND POWER DOPPLER ANGIOGRAPHY (3D-PDA) FOR ASSESSMENT OF PLACENTAL VOLUME AND VASCULARITY IN THE SECOND TRIMESTER OF PREGNANCY
    Jones, Nia W.
    Raine-Fenning, Nick J.
    Mousa, Hatem A.
    Bradley, Eileen
    Bugg, George J.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2011, 37 (03): : 376 - 385
  • [35] The intra- and inter-rater reliability of manual muscle testing and a hand-held dynamometer for measuring wrist strength in symptomatic and asymptomatic subjects
    Toemen, Angela
    Dalton, Sarah
    Sandford, Fiona
    HAND THERAPY, 2011, 16 (03) : 67 - 74
  • [36] Assessing the viscoelastic properties of upper trapezius muscle: Intra- and inter-tester reliability and the effect of shoulder elevation
    Liu, C. L.
    Feng, Y. N.
    Zhang, H. Q.
    Li, Y. P.
    Zhu, Y.
    Zhang, Z. J.
    JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2018, 43 : 226 - 229
  • [37] Reliability of Single-Slice-Based 2D CT Texture Analysis of Renal Masses: Influence of Intra- and Interobserver Manual Segmentation Variability on Radiomic Feature Reproducibility
    Kocak, Burak
    Durmaz, Emine Sebnem
    Kaya, Ozlem Korkmaz
    Ates, Ece
    Kilickesmez, Ozgur
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2019, 213 (02) : 377 - 383
  • [38] LiLa classification for paediatric long bone fractures: Intraobserver and interobserver reliability [LiLa-Klassifikation für Frakturen der langen Röhrenknochen im Wachstumsalter: Intra- und Interobserverreliabilität]
    Kamphaus A.
    Rapp M.
    Wessel L.M.
    Buchholz M.
    Massalme E.
    Schneidmüller D.
    Roeder C.
    Kaiser M.M.
    Der Unfallchirurg, 2015, 118 (4): : 326 - 335