The effect of labeling photo documents in wrist arthroscopies on intra- and interobserver reliability

被引:13
|
作者
Loew, Steffen [1 ]
Herold, Dirk [1 ]
Muehldorfer-Fodor, Marion [2 ]
Pillukat, Thomas [2 ]
机构
[1] Caritas Krankenhaus, Sect Hand Surg, Clin Orthopaed & Trauma Surg, D-97980 Bad Mergentheim, Germany
[2] Rhon Klinikum AG, Clin Hand Surg, Bad Neustadt an der Saale, Germany
关键词
Interobserver; Intraobserver; Labeling; Reliability; Photo documents; Wrist arthroscopy; TRIANGULAR FIBROCARTILAGE COMPLEX; CLASSIFICATION; LESIONS; AGREEMENT; REPAIR; TEARS;
D O I
10.1007/s00402-012-1612-6
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction The reproducibility of diagnoses based on photo documents in wrist arthroscopies is limited and is expected to improve if the photos are labeled with illustrated structures. Aim The purpose of this study was to determine the effect of labeling photo documents on intra- and interobserver agreement and reliability of standard photo documentation in wrist arthroscopies. Materials and methods Digital photographs of 50 arthroscopies were re-evaluated by the surgeon as well as by two independent hand surgeons. First the photos were presented unlabeled in a random order, then the labeled photos in a uniform order. Intra- and interobserver reliability was assessed, and expressed by kappa coefficients. Results Overall, labeling the photos resulted in a slight improvement in intra- and interobserver reliability (0.573/0.444/0.420 vs. 0.518/0.412/0.212). The time needed to conceive the photo documents, however, was shortened when the photos were labeled. The cartilage status was assessed considerably more accurately if the photos were labeled (0.556/0.560/0.422 vs. 0.459/0.326/0.240; t test: P = 0.094). Whereas the SL ligament was assessed more accurately according to labeled photos (P = 0.100), the agreement rates for the assessment of other ligament structures (TFCC, LT and radiopalmar ligaments) were not substantially affected by labeling the photos. On re-evaluation of the unlabeled as well as the labeled photos, intraobserver reliability was better than interobserver reliability (0.518 vs. 0.412/0.212 and 0.573 vs. 0.444/0.420). Conclusion Labeling simplifies but does not necessarily improve the reproducibility of photo documents in wrist arthroscopies. To display the cartilage status and the integrity of the SL ligament, digital photo documents should be labeled with the illustrated structure or joint surface.
引用
收藏
页码:1813 / 1818
页数:6
相关论文
共 50 条
  • [21] Intra- and Interobserver Reliability of the New Classification System of Progressive Collapsing Foot Deformity
    Lee, Hee Young
    Mansur, Nacime Salomao Barbachan
    Lalevee, Matthieu
    Dibbern, Kevin N.
    Myerson, Mark S.
    Ellis, Scott J.
    Femino, John E.
    Netto, Cesar de Cesar
    FOOT & ANKLE INTERNATIONAL, 2022, 43 (04) : 582 - 589
  • [22] Ultrasonographic measurement of patellar tendon thickness-a study of intra- and interobserver reliability
    Skou, Soren T.
    Aalkjaer, Johanne M.
    CLINICAL IMAGING, 2013, 37 (05) : 934 - 937
  • [23] Comparability and intra-/interobserver reliability of anterior chamber depth measurements with the Pentacam and IOLMaster
    Savant, Vijay
    Chavan, Randhir
    Pushpoth, Sreekumari
    Ilango, B.
    JOURNAL OF REFRACTIVE SURGERY, 2008, 24 (06) : 615 - 618
  • [24] Comparison of intra- and interobserver reliability with computed and conventional radiography for spinal deformity.
    McGahan, P. J.
    Kuo, C.
    Gupta, M. C.
    JOURNAL OF INVESTIGATIVE MEDICINE, 2007, 55 (01) : S105 - S105
  • [25] Templating in uncemented total hip arthroplasty-on intra- and interobserver reliability and professional experience
    Strom, Nils J.
    Pripp, Are Hugo
    Reikeras, Olav
    ANNALS OF TRANSLATIONAL MEDICINE, 2017, 5 (03)
  • [26] Evaluating the Endoscopic Reference Score for eosinophilic esophagitis: moderate to substantial intra- and interobserver reliability
    van Rhijn, Bram D.
    Warners, Marijn J.
    Curvers, Wouter L.
    van Lent, Anja U.
    Bekkali, Noor L.
    Takkenberg, R. Bart
    Kloek, Jaap J.
    Bergman, Jacques J. G. H. M.
    Fockens, Paul
    Bredenoord, Albert J.
    ENDOSCOPY, 2014, 46 (12) : 1049 - 1055
  • [27] Interobserver reliability of scapula fracture classifications in intra- and extra-articular injury patterns
    Huflage, Henner
    Fieber, Tabea
    Farber, Christian
    Knarr, Jonas
    Veldhoen, Simon
    Jordan, Martin C.
    Gilbert, Fabian
    Bley, Thorsten Alexander
    Meffert, Rainer H.
    Grunz, Jan-Peter
    Schmalzl, Jonas
    BMC MUSCULOSKELETAL DISORDERS, 2022, 23 (01)
  • [28] Interobserver reliability of scapula fracture classifications in intra- and extra-articular injury patterns
    Henner Huflage
    Tabea Fieber
    Christian Färber
    Jonas Knarr
    Simon Veldhoen
    Martin C. Jordan
    Fabian Gilbert
    Thorsten Alexander Bley
    Rainer H. Meffert
    Jan-Peter Grunz
    Jonas Schmalzl
    BMC Musculoskeletal Disorders, 23
  • [29] The intra- and interobserver reliability of the Tile AO, the Young and Burgess, and FFP classifications in pelvic trauma
    Berger-Groch, Josephine
    Thiesen, Darius M.
    Grossterlinden, Lars G.
    Schaewel, Jan
    Fensky, Florian
    Hartel, Maximilian J.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2019, 139 (05) : 645 - 650
  • [30] Intra- and interobserver reliability in measuring aortic root rotation with cardiac magnetic resonance imaging
    Voortman, Marco
    Fitski, Wouter
    van Es, Jan
    Doggen, Carine J. M.
    Plonek, Tomasz
    von Birgelen, Clemens
    Wagenaar, Lodewijk J.
    CARDIOVASCULAR DIAGNOSIS AND THERAPY, 2024, 14 (02) : 264 - 271