Impact of operating parameters on 80 K pulse tube cryocoolers for space applications

被引:8
|
作者
Liu, Shaoshuai [1 ]
Jiang, Zhenhua [1 ]
Ding, Lei [1 ]
Zhu, Haifeng [1 ]
Huang, Qi [1 ]
Wu, Yinong [1 ]
机构
[1] Chinese Acad Sci, Shanghai Inst Tech Phys, 500 Yutian Rd, Shanghai 200083, Peoples R China
来源
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID | 2019年 / 99卷
基金
中国博士后科学基金; 上海市自然科学基金;
关键词
Pulse tube cryocooler; Frequency; Pressure; Cooling performance; 80; K; PHASE-SHIFTER;
D O I
10.1016/j.ijrefrig.2018.12.026
中图分类号
O414.1 [热力学];
学科分类号
摘要
Pulse tube cryocoolers (PTCs) represent a significant enabling technology for infrared detectors in space applications. A PTC can be efficiently operated by optimizing the structural parameters and impedance characteristics among different components. While the structures of the components are determined, the operating parameters are the most effective and simple methods to optimize the cooling performance of a PTC. The regenerator losses (regenerative losses, heat conduction losses and pressure drop losses) and the phase shifting ability (phase angle) are affected by the operating parameters. Based on theoretical and simulated analysis, the effects of operating parameters on the linear motor, regenerator and phase shifter are investigated. The pressure ratio, waveforms of the pressure and displacement, phase angle, motor efficiency, input power and cooling capacity are then presented by an experiment to clarify the influence mechanism. The pressure ratio and phase characteristics at the entrances of the regenerator and inertance tube are changed with different operating parameters. Corresponding with the piston displacement and motor efficiency, there is an optimal average pressure for the best cooling efficiency. The results show that a high compressor efficiency of 88% and a relative Carnot efficiency (rCOP) of 16.08% is achieved at 2.5 MPa and 51 Hz, while a relative Carnot efficiency of 16.0% is achieved at 3.5 MPa and 52 Hz by optimizing the frequency and pressure. (C) 2018 Published by Elsevier Ltd.
引用
收藏
页码:226 / 233
页数:8
相关论文
共 31 条
  • [1] A critical review of liquid helium temperature high frequency pulse tube cryocoolers for space applications
    Wang, B.
    Gan, Z. H.
    PROGRESS IN AEROSPACE SCIENCES, 2013, 61 : 43 - 70
  • [2] Cold inertance tube for 4 K Stirling type pulse tube cryocoolers
    Li, ZhuoPei
    Gan, ZhiHua
    Qiu, LiMin
    PROCEEDINGS OF THE 25TH INTERNATIONAL CRYOGENIC ENGINEERING CONFERENCE AND INTERNATIONAL CRYOGENIC MATERIALS CONFERENCE 2014, 2015, 67 : 451 - 455
  • [3] Development of Pulse Tube Cryocoolers at SITP for Space Application
    Zhang, Ankuo
    Wu, Yinong
    Liu, Shaoshuai
    Yu, Huiqin
    Yang, Baoyu
    JOURNAL OF LOW TEMPERATURE PHYSICS, 2018, 191 (3-4) : 228 - 241
  • [4] Development of Pulse Tube Cryocoolers at SITP for Space Application
    Ankuo Zhang
    Yinong Wu
    Shaoshuai Liu
    Huiqin Yu
    Baoyu Yang
    Journal of Low Temperature Physics, 2018, 191 : 228 - 241
  • [5] High-frequency two-stage gas-bearing pulse tube cryocoolers at 20 K for space applications
    Zhou, Ji
    Zhi, Xiaoqing
    Ni, Zhuqing
    Cao, Rongfei
    Liu, Zhimin
    Huang, Changning
    Wang, Bo
    Li, Guoliang
    Huang, Chen
    Zhang, Yanhu
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2023, 46
  • [6] STUDY OF LOW VIBRATION 4 K PULSE TUBE CRYOCOOLERS
    Xu, M. Y.
    Nakano, K.
    Saito, M.
    Takayama, H.
    Tsuchiya, A.
    Maruyama, H.
    ADVANCES IN CRYOGENIC ENGINEERING, VOLS 57A AND 57B, 2012, 1434 : 190 - 197
  • [7] A lightweight high-capacity pulse tube cryocooler operating at 80 K
    Wang, Nailiang
    Tang, Qingjun
    Xun, Yuqiang
    Liang, Menglin
    Zhao, Miguang
    Chen, Houlei
    Liang, Jingtao
    CRYOGENICS, 2024, 138
  • [8] Comparison of three phase shifters for Stirling-type pulse tube cryocoolers operating below 30 K
    Zhu, Haifeng
    Jiang, Zhenhua
    Liu, Shaoshuai
    Jiang, Yanyang
    Wu, Yinong
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2018, 88 : 413 - 419
  • [9] 40 K single-stage coaxial pulse tube cryocoolers
    Dang, Haizheng
    CRYOGENICS, 2012, 52 (4-6) : 216 - 220
  • [10] A HELIUM LIQUEFIER USING THREE 4 K PULSE TUBE CRYOCOOLERS
    Wang, C.
    Oviedo, A.
    ADVANCES IN CRYOGENIC ENGINEERING, VOLS 57A AND 57B, 2012, 1434 : 1640 - 1646