The Monte Carlo method to determine the error in calculation of objective acoustic parameters within the ray-tracing technique

被引:4
作者
Giner, J [1 ]
Militello, C
García, A
机构
[1] Univ La Laguna, Dept Financial Econ & Accounting, La Laguna 38071, Spain
[2] Univ La Laguna, Dept Fundamental & Expt Phys, E-38207 La Laguna, Spain
[3] Univ Valencia, Dept Appl Phys, Burjassot 46100, Valencia, Spain
关键词
D O I
10.1121/1.1409373
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
This article is an extension of the procedure to estimate errors in ray-tracing calculations of room response proposed by Giner et al. [J. Acoust. Soc. Am. 106, 816-823 (1999)]. The previous article presented an expression to estimate the error in computing the energy reaching a receptor during a small time interval. This expression was obtained assuming that a pure ray-tracing program is used and a Monte Carlo Technique is applied. In the present work these ideas are extended in order to compute the objective acoustic parameters of a room. The corresponding equations are presented in closed form. Our results show that the number of rays involved in the analysis depends on the nature of the parameters to be evaluated. Some examples are shown in order to validate our conclusions. (C) 2001 Acoustical Society of America.
引用
收藏
页码:3081 / 3085
页数:5
相关论文
共 7 条
[1]  
[Anonymous], 1979, ROOM ACOUSTICS
[2]  
Cremer L., 1982, PRINCIPLES APPL ROOM
[3]   Ascertaining confidence within the ray-tracing method [J].
Giner, J ;
Militello, C ;
García, A .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1999, 106 (02) :816-822
[4]   EXTENDING THE IMAGE METHOD TO HIGHER-ORDER REFLECTIONS [J].
KRISTIANSEN, UR ;
KROKSTAD, A ;
FOLLESTAD, T .
APPLIED ACOUSTICS, 1993, 38 (2-4) :195-206
[5]  
KULLOWSKY A, 1982, APPL ACOUST, V15, P263
[6]  
VORLANDER M, 1988, ACUSTICA, V66, P90
[7]  
VORLANDER M, COMMUNICATION