Comparison of icodextrin and glucose solutions for the daytime dwell in automated peritoneal dialysis

被引:64
|
作者
Woodrow, G
Stables, G
Oldroyd, B
Gibson, J
Turney, JH
Brownjohn, AM
机构
[1] Gen Infirm, Renal Unit, Leeds LS1 3EX, W Yorkshire, England
[2] Univ Leeds, Ctr Bone & Body Composit Res, Leeds LS2 9JT, W Yorkshire, England
关键词
automated peritoneal dialysis; dialysis adequacy; icodextrin; ultrafiltration;
D O I
10.1093/ndt/14.6.1530
中图分类号
R3 [基础医学]; R4 [临床医学];
学科分类号
1001 ; 1002 ; 100602 ;
摘要
Background. The sustained ultrafiltration achieved by icodextrin is more suited for the daytime dwell in automated peritoneal dialysis (APD) than glucose solutions. Methods. Seventeen patients receiving APD underwent assessment using three different solutions for the daytime dwell: 2.27% glucose, 3.86% glucose and 7.5% icodextrin. Patients were then observed on icodextrin for a 6 month period. Results. Daytime ultrafiltration was greater for 3.86% glucose (median 0.10, IQR 0.01 to 0.321) P<0.01 and icodextrin (median 0.26, IQR 0.14 to 0.361) P<0.001 than 2.27% glucose (median -0.19, IQR -0.54 to -0.081), with 3.86% glucose and icodextrin not being significantly different. Positive ultrafiltration occurred in 3/17 patients with 2.27% glucose, 13/17 patients with 3.86% glucose and 16/17 patients with icodextrin (chi(2) P<0.0001). The difference in ultrafiltration of icodextrin and 3.86% glucose correlated with the 4h dialysate/plasma creatinine ratio in a PET test (r= 0.51, P<0.05). Daytime Kt/V urea was greater for 3.86% glucose (median 0.27, IQR 0.20 to 0.48 per week. P<0.01) and icodextrin (median 0.31, IQR 0.27 to 0.49 per week, P<0.0001) than for 2.27% glucose (median 0.22. IQR 0.15 to 0.38 per week), with the difference between 3.86% glucose and icodextrin not reaching statistical significance (P=0.06). Daytime creatinine clearance was greater for 3.86% glucose (median 10.2, IQR 6.9 to 13.61/week/1.73 m(2), P<0.02) and icodextrin (median 12.1, IQR 9.3 to 15.71/week/1.73 m(2), P<0.005) than for 2.27% glucose (median 8.8, IQR 4.9 to 11.91/week/1.73 m(2)). Daytime creatinine clearance was greater for icodextrin than for 3.86% glucose (P<0.005). The effects of icodextrin were sustained for the 6 month observation period. Conclusions. Icodextrin produced enhanced ultrafiltration and clearances compared with 2.27% glucose, without the exposure of the peritoncum to hypertonic glucose solutions.
引用
收藏
页码:1530 / 1535
页数:6
相关论文
共 50 条
  • [31] Comparison of clinical effects between icodextrin and glucose solutions on outcomes of peritoneal dialysis: systematic review and meta-analysis of randomized controlled trials
    Kanno, Atsuhiro
    Tsujimoto, Yasushi
    Fujii, Takayuki
    Fujikura, Emi
    Watanabe, Kimio
    Yuasa, Hidemichi
    Ryuzaki, Munekazu
    Ito, Yasuhiko
    Nakamoto, Hidetomo
    RENAL REPLACEMENT THERAPY, 2020, 6 (01)
  • [32] Pharmacokinetics of icodextrin in peritoneal dialysis patients
    Moberly, JB
    Mujais, S
    Gehr, T
    Hamburger, R
    Sprague, S
    Kucharski, A
    Reynolds, R
    Ogrinc, F
    Martis, L
    Wolfson, M
    KIDNEY INTERNATIONAL, 2002, 62 : S23 - S33
  • [33] INTRAPERITONEAL IL-6 SIGNALING IN INCIDENT PATIENTS TREATED WITH ICODEXTRIN AND GLUCOSE BICARBONATE/LACTATE-BASED PERITONEAL DIALYSIS SOLUTIONS
    Opatrna, Sylvie
    Lysak, Daniel
    Trefil, Ladislav
    Parker, Clare
    Topley, Nicholas
    PERITONEAL DIALYSIS INTERNATIONAL, 2012, 32 (01): : 37 - 44
  • [34] Possible applications of polyglucose (icodextrin) as a peritoneal dialysis fluid
    Roob, JM
    WIENER KLINISCHE WOCHENSCHRIFT, 2000, 112 : 43 - 46
  • [35] Clinical effects of icodextrin in peritoneal dialysis
    Cnossen, Trijntje T.
    Konings, Constantijn J.
    van der Sande, Frank M.
    Leunissen, Karel M.
    Kooman, Jeroen P.
    CLINICAL KIDNEY JOURNAL, 2008, 1 : IV18 - IV22
  • [36] Comparison of sodium removal in peritoneal dialysis patients treated by continuous ambulatory and automated peritoneal dialysis
    Maharjan, Sarju Raj Singh
    Davenport, Andrew
    JOURNAL OF NEPHROLOGY, 2019, 32 (06) : 1011 - 1019
  • [37] Comparison of sodium removal in peritoneal dialysis patients treated by continuous ambulatory and automated peritoneal dialysis
    Sarju Raj Singh Maharjan
    Andrew Davenport
    Journal of Nephrology, 2019, 32 : 1011 - 1019
  • [38] Sex Modulates Cardiovascular Effects of Icodextrin-Based Peritoneal Dialysis Solutions
    Paniagua, Ramon
    Garcia-Lopez, Elvia
    Avila-Diaz, Marcela
    Ventura, Maria-de-Jesus
    Orihuela, Oscar
    Prado-Uribe, Maria-del-Carmen
    Gallardo-Montoya, Juan-Manuel
    Lindholm, Bengt
    FRONTIERS IN PHYSIOLOGY, 2022, 13
  • [39] Icodextrin and peritoneal dialysis: advantages and new applications
    Periklis Dousdampanis
    Carlos Guido Musso
    Konstantina Trigka
    International Urology and Nephrology, 2018, 50 : 495 - 500
  • [40] Recommendations for the use of icodextrin in peritoneal dialysis patients
    Johnson, DW
    Agar, J
    Collins, J
    Disney, A
    Harris, DCH
    Ibels, L
    Irish, A
    Saltissi, D
    Suranyi, M
    NEPHROLOGY, 2003, 8 (01) : 1 - 7