Comparison of icodextrin and glucose solutions for the daytime dwell in automated peritoneal dialysis

被引:64
作者
Woodrow, G
Stables, G
Oldroyd, B
Gibson, J
Turney, JH
Brownjohn, AM
机构
[1] Gen Infirm, Renal Unit, Leeds LS1 3EX, W Yorkshire, England
[2] Univ Leeds, Ctr Bone & Body Composit Res, Leeds LS2 9JT, W Yorkshire, England
关键词
automated peritoneal dialysis; dialysis adequacy; icodextrin; ultrafiltration;
D O I
10.1093/ndt/14.6.1530
中图分类号
R3 [基础医学]; R4 [临床医学];
学科分类号
1001 ; 1002 ; 100602 ;
摘要
Background. The sustained ultrafiltration achieved by icodextrin is more suited for the daytime dwell in automated peritoneal dialysis (APD) than glucose solutions. Methods. Seventeen patients receiving APD underwent assessment using three different solutions for the daytime dwell: 2.27% glucose, 3.86% glucose and 7.5% icodextrin. Patients were then observed on icodextrin for a 6 month period. Results. Daytime ultrafiltration was greater for 3.86% glucose (median 0.10, IQR 0.01 to 0.321) P<0.01 and icodextrin (median 0.26, IQR 0.14 to 0.361) P<0.001 than 2.27% glucose (median -0.19, IQR -0.54 to -0.081), with 3.86% glucose and icodextrin not being significantly different. Positive ultrafiltration occurred in 3/17 patients with 2.27% glucose, 13/17 patients with 3.86% glucose and 16/17 patients with icodextrin (chi(2) P<0.0001). The difference in ultrafiltration of icodextrin and 3.86% glucose correlated with the 4h dialysate/plasma creatinine ratio in a PET test (r= 0.51, P<0.05). Daytime Kt/V urea was greater for 3.86% glucose (median 0.27, IQR 0.20 to 0.48 per week. P<0.01) and icodextrin (median 0.31, IQR 0.27 to 0.49 per week, P<0.0001) than for 2.27% glucose (median 0.22. IQR 0.15 to 0.38 per week), with the difference between 3.86% glucose and icodextrin not reaching statistical significance (P=0.06). Daytime creatinine clearance was greater for 3.86% glucose (median 10.2, IQR 6.9 to 13.61/week/1.73 m(2), P<0.02) and icodextrin (median 12.1, IQR 9.3 to 15.71/week/1.73 m(2), P<0.005) than for 2.27% glucose (median 8.8, IQR 4.9 to 11.91/week/1.73 m(2)). Daytime creatinine clearance was greater for icodextrin than for 3.86% glucose (P<0.005). The effects of icodextrin were sustained for the 6 month observation period. Conclusions. Icodextrin produced enhanced ultrafiltration and clearances compared with 2.27% glucose, without the exposure of the peritoncum to hypertonic glucose solutions.
引用
收藏
页码:1530 / 1535
页数:6
相关论文
共 20 条
[1]  
BOESCHOTEN EW, 1988, PERITON DIALYSIS INT, V8, P19
[2]   SURVIVAL AS AN INDEX OF ADEQUACY OF DIALYSIS [J].
CHARRA, B ;
CALEMARD, E ;
RUFFET, M ;
CHAZOT, C ;
TERRAT, JC ;
VANEL, T ;
LAURENT, G .
KIDNEY INTERNATIONAL, 1992, 41 (05) :1286-1291
[3]  
Coles GA, 1997, PERITON DIALYSIS INT, V17, P321
[4]  
COOPER A, 1995, J EDTNA ERCA S1, V21, P21
[5]  
Davis M. M., 1994, International Journal of Operations & Production Management, V14, P21, DOI 10.1108/01443579410056777
[6]  
Dawnay ABSJ, 1997, PERITON DIALYSIS INT, V17, P52
[7]  
Diaz-Buxo JA, 1987, PERIT DIAL B S2, V7, pS22
[8]  
FENSTROM A, 1998, PERITON DIALYSIS INT, V18, P166
[9]   Peritoneal transport characteristics with glucose polymer based dialysate [J].
HoDacPannekeet, MM ;
Schouten, N ;
Langendijk, MJ ;
Hiralall, JK ;
deWaart, DR ;
Struijk, DG ;
Krediet, RT .
KIDNEY INTERNATIONAL, 1996, 50 (03) :979-986
[10]  
Krediet RT, 1997, PERITON DIALYSIS INT, V17, P35