Myocardial perfusion monitoring during coronary artery bypass using an electrocardiogram-triggered laser Doppler technique

被引:10
|
作者
Karlsson, MGD [1 ]
Fors, C
Wårdell, K
Casimir-Ahn, H
机构
[1] Linkoping Univ, Dept Biomed Engn, Linkoping, Sweden
[2] Linkoping Univ Hosp, Ctr Heart, S-58185 Linkoping, Sweden
关键词
laser Doppler perfusion monitoring; coronary artery bypass grafting; beating heart; myocardial microcirculation; movement artifacts; electrocardiography;
D O I
10.1007/BF02351031
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Electrocardiogram (ECG)-triggered laser Doppler perfusion monitoring (LDPM) was used to assess myocardial perfusion, with minimum myocardial tissue motion influence, during coronary artery bypass grafting (CABG). Thirteen subjects were investigated at six phases: pre- and post-CABG; post aorta cross-clamping; pre and post left internal mammary artery (LIMA) graft declamping, and post aorta declamping. The perfusion signal was calculated in late systole and late diastole, with expected minimum tissue motion, and compared with arrested heart measurements. Patient conditions or artifacts caused by surgical activity made it impossible to perform and analyse data in all six phases for some patients. No significant (n = 5) difference between perfusion signals pre- and post-CABG was found. Diastolic perfusion signal levels were significantly (p < 0.02) lower compared with systolic levels. After aorta cross-clamping, the signal level was almost zero. A distinct perfusion signal increase after LIMA and aorta declamping, compared with pre-LIMA declamping, was found in ten cases out of 13. A significantly (p < 0.04) lower perfusion signal in the arrested heart compared with in the beating heart was registered. Influence from mechanical ventilation was observed in 14 measurements out of 17. In conclusion, ECG-triggered LDPM can be used to assess myocardial perfusion during CABG. Perfusion signals were lower in the arrested heart compared with in the beating heart and in late diastole compared with late systole. No significant difference between pre- and post-CABG was found.
引用
收藏
页码:582 / 588
页数:7
相关论文
共 50 条
  • [1] Myocardial perfusion monitoring during coronary artery bypass using an electrocardiogram-triggered laser Doppler technique
    M. G. D. Karlsson
    C. Fors
    K. Wårdell
    H. Casimir-Ahn
    Medical and Biological Engineering and Computing, 2005, 43 : 582 - 588
  • [2] Myocardial tissue motion influence on laser Doppler perfusion monitoring using tissue Doppler imaging
    M. G. D. Karlsson
    L. Hübbert
    U. Lönn
    B. Janerot-Sjöberg
    H. Casimir-Ahn
    K. Wårdell
    Medical and Biological Engineering and Computing, 2004, 42 : 770 - 776
  • [3] Myocardial tissue motion influence on laser Doppler perfusion monitoring using tissue Doppler imaging
    Karlsson, MGD
    Hübbert, L
    Lönn, U
    Janerot-Sjöberg, B
    Casimir-Ahn, H
    Wårdell, K
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2004, 42 (06) : 770 - 776
  • [4] A system for on-line laser Doppler monitoring of ECG-traced myocardial perfusion
    Fors, C
    Karlsson, MGD
    Ahn, HC
    Wårdell, K
    PROCEEDINGS OF THE 26TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2004, 26 : 3796 - 3799
  • [5] A mystery of the myocardial microcirculation during coronary artery bypass grafting
    Hellmann, Marcin
    Piotrowski, Jakub
    Anisimowicz, Lech
    Cracowski, Jean-Luc
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2018, 54 (02) : 405 - 405
  • [6] Outcomes of coronary artery bypass grafting based on myocardial perfusion imaging
    Sharma, Vishesh
    Jain, Anil
    Patel, Vishal
    Pandya, Himani
    Choudhari, Amit
    KARDIOCHIRURGIA I TORAKOCHIRURGIA POLSKA-POLISH JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2023, 20 (03) : 161 - 166
  • [7] Scintigraphic demonstration of myocardial perfusion and ischaemia associated with coronary artery bypass grafting
    Larstorp, Anne Cecilie K.
    Soraas, Camilla Lund
    Tonnessen, Theis
    Muller, Carl
    Kjeldsen, Sverre E.
    Mangschau, Arild
    SCANDINAVIAN CARDIOVASCULAR JOURNAL, 2006, 40 (06) : 354 - 362
  • [8] Effect of coronary artery bypass surgery on myocardial function as assessed by tissue Doppler echocardiography
    Diller, Gerhard-Paul
    Wasan, Balvinder S.
    Kyriacou, Andreas
    Patel, Niket
    Casula, Roberto P.
    Athanasiou, Thanos
    Francis, Darrel P.
    Mayet, Jamil
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2008, 34 (05) : 995 - 999
  • [9] Myocardial Perfusion Imaging After Coronary Artery Bypass Surgery Using Cardiovascular Magnetic Resonance A Validation Study
    Arnold, J. Ranjit
    Francis, Jane M.
    Karamitsos, Theodoros D.
    Lim, Chris C.
    van Gaal, William J.
    Testa, Luca
    Bhamra-Ariza, Paul
    Selvanayagam, Joseph B.
    Sayeed, Rana
    Westaby, Stephen
    Banning, Adrian P.
    Neubauer, Stefan
    Jerosch-Herold, Michael
    CIRCULATION-CARDIOVASCULAR IMAGING, 2011, 4 (03) : 312 - 318
  • [10] Invasive Assessment of the Myocardial Microcirculation during Beating Heart Coronary Artery Bypass Grafting
    Hellmann, Marcin
    Piotrowski, Jakub
    Kaszubowski, Mariusz
    Dudziak, Maria
    Anisimowicz, Lech
    JOURNAL OF CLINICAL MEDICINE, 2020, 9 (03)