Flexible cryogenic air separation unit-An application for low-carbon fossil-fuel plants

被引:15
作者
Cheng, Mao [1 ]
Verma, Piyush [1 ]
Yang, Zhiwei [1 ]
Axelbaum, Richard L. [1 ]
机构
[1] Washington Univ, Dept Energy Environm & Chem Engn, Consortium Clean Coal Utilizat, One Brookings Dr, St Louis, MO 63130 USA
关键词
Rapidly-ramping ASU; O2 product purity; Vapor-liquid countercurrent flows; Heat integration; Mismatched dynamics; POWER-PLANTS; SYSTEM; FLEXIBILITY; CAPTURE;
D O I
10.1016/j.seppur.2022.122086
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The rapid integration of intermittent renewable sources into the electricity grid is driving the need for a flexible cryogenic air separation unit (ASU) coupled with a low-carbon fossil-fuel plant. However, the state-of-the-art ASU process is highly integrated and nonlinear, which can significantly restrict its ramping rate. In this work, we study the fundamental dynamics of a state-of-the-art double-column ASU, focusing on the dynamic charac-teristics of the highly integrated and nonlinear heat and mass transfers, and we propose basic control methods for achieving high process ramping rates. We found that the vapor-liquid countercurrent flows in the low-pressure column are critical to the cryogenic rectification of air, which governs the ramp rate of the ASU. This coun-tercurrent flow structure is created through a complex heat integration process in the ASU. Here, this process is simplified as a countercurrent heat transfer to reduce the complexity of studying the ASU dynamics. To preserve this flow structure, the heat integration is maintained so that its heat duty follows the ASU load, using several basic controllers on the critical stream flowrates. A flow-driven dynamic ASU model is built in Aspen Plus Dy-namics to capture the basic ramping dynamics. This model revealed a fundamental mismatch in the dynamics in the ASU column that causes a significant loss of O2 product purity when ramping down the ASU and slightly increases the purity when ramping up. Based on these findings, we propose a basic control method for rapidly ramping down/up the ASU while maintaining O2 product purity. Simulation results show the ASU basic dynamic process successfully ramps at a rate up to 10 %/min (40-100 % load) while maintaining the O2 product purity at 95.2-95.6 mol%.
引用
收藏
页数:9
相关论文
共 31 条
[11]   Experimental study on oxy-fuel combustion behavior of lignite char and carbon transfer mechanism with isotopic tracing method [J].
Geng, Chenchen ;
Shao, Yingjuan ;
Bian, Zhoufeng ;
Zhong, Wenqi .
CHEMICAL ENGINEERING JOURNAL, 2020, 386
[12]  
Goloubev D., 2013, 3 OXYFUEL COMBUSTION
[13]  
Goloubev D., 2012, WORKSH OX FBC TECHN
[14]  
Jahnke F.C., 2000, USA Patent, Patent No. [6,134,916, 6134916]
[15]   Plantwide control and operating strategy for air separation unit in oxy-combustion power plants [J].
Jin, Bo ;
Su, Mingze ;
Zhao, Haibo ;
Zheng, Chuguang .
ENERGY CONVERSION AND MANAGEMENT, 2015, 106 :782-792
[16]   Pressure-driven dynamic simulation of start up and shutdown procedures of distillation columns in air separation units [J].
Kender, Robert ;
Wunderlich, Bernd ;
Thomas, Ingo ;
Peschel, Andreas ;
Rehfeldt, Sebastian ;
Klein, Harald .
CHEMICAL ENGINEERING RESEARCH & DESIGN, 2019, 147 :98-112
[17]   Value of power plant flexibility in power systems with high shares of variable renewables: A scenario outlook for Germany 2035 [J].
Kopiske, Jakob ;
Spieker, Sebastian ;
Tsatsaronis, George .
ENERGY, 2017, 137 :823-833
[18]   Co-firing of coal and biomass under pressurized oxy-fuel combustion mode: Experimental test in a 10 kWth fluidized bed [J].
Liu, Qinwen ;
Zhong, Wenqi ;
Yu, Aibing ;
Wang, Chi-Hwa .
CHEMICAL ENGINEERING JOURNAL, 2022, 431
[19]  
Lockwood T., 2014, Developments in oxyfuel combustion of coal
[20]   Control of a recuperative vapor-recompression air separation process [J].
Luyben, William L. .