Preclinical modeling of low energy X-rays radiological burn: Dosimetry study by monte carlo simulations and EPR spectroscopy

被引:4
|
作者
Guillou, Manon [1 ]
L'Homme, Bruno [1 ]
Trompier, Francois [2 ]
Gruel, Gaetan [1 ]
Prezado, Yolanda [3 ]
Dos Santos, Morgane [1 ]
机构
[1] Inst Radioprotect & Surete Nucleaire IRSN, PSE SANTE SERAMED LRAcc, Fontenay Aux Rroses, France
[2] Inst Radioprotect & Surete Nucleaire IRSN, PSE SANTE SDOS LDRI, Fontenay Aux Roses, France
[3] Univ Paris Saclay, PSL Res Univ, Inst Curie, Inserm U 1021 CNRS ,UMR 3347, Orsay, France
关键词
dosimetry; low energy X-rays; interventional radiology; radiological burn; preclinical model; EPR spectroscopy; Monte Carlo simulation; KILOVOLTAGE PHOTON; RADIATION-THERAPY; DOSE PERTURBATION; BONE; RADIOTHERAPY; ACCIDENT; PLATFORM;
D O I
10.3389/fphys.2022.1075665
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Interventional radiology has grown considerably over the last decades and become an essential tool for treatment or diagnosis. This technique is mostly beneficial and mastered but accidental overexposure can occur and lead to the appearance of deterministic effects. The lack of knowledge about the radiobiological consequences for the low-energy X-rays used for these practices makes the prognosis very uncertain for the different tissues. In order to improve the radiation protection of patients and better predict the risk of complications, we implemented a new preclinical mouse model to mimic radiological burn in interventional radiology and performed a complete characterization of the dose deposition. A new setup and collimator were designed to irradiate the hind legs of 15 mice at 30 Gy in air kerma at 80 kV. After irradiation, mice tibias were collected to evaluate bone dose by Electron Paramagnetic Resonance (EPR) spectroscopy measurements. Monte Carlo simulations with Geant4 were performed in simplified and voxelized phantoms to characterize the dose deposition in different tissues and evaluate the characteristics of secondary electrons (energy, path, momentum). 30 mice tibias were collected for EPR analysis. An average absorbed dose of 194.0 & PLUSMN; 27.0 Gy was measured in bone initially irradiated at 30 Gy in air kerma. A bone to air conversion factor of 6.5 & PLUSMN; 0.9 was determined. Inter sample and inter mice variability has been estimated to 13.9%. Monte Carlo simulations shown the heterogeneity of the dose deposition for these low X-rays energies and the dose enhancement in dense tissue. The specificities of the secondary electrons were studied and showed the influence of the tissue density on energies and paths. A good agreement between the experimental and calculated bone to air conversion factor was obtained. A new preclinical model allowing to perform radiological burn in interventional radiology-like conditions was implemented. For the development of new preclinical radiobiological model where the exact knowledge of the dose deposited in the different tissues is essential, the complementarity of Monte Carlo simulations and experimental measurements for the dosimetric characterization has proven to be a considerable asset.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Design, fabrication and characterization of a windowless extrapolation chamber for low-energy X-rays: Experimental and Monte Carlo results
    Vahabi, Seyed Milad
    Zafarghandi, Mojtaba Shamsaie
    VACUUM, 2019, 161 : 194 - 200
  • [22] TLD-700 for proton dosimetry in the presence of low-energy X-rays
    Miljanic, S
    Ranogajec-Komor, M
    Blagus, S
    Miljanic, D
    Osvay, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 519 (03): : 667 - 673
  • [23] X-RAYS FROM THE ACCRETION COLUMN OF COMPACT OBJECTS - A MONTE-CARLO STUDY
    FELSTEINER, J
    OPHER, R
    PROCEEDINGS OF THE 23RD ESLAB SYMPOSIUM ON TWO TOPICS IN X-RAY ASTRONOMY, VOLS 1 AND 2: X-RAY BINARIES; AGN AND THE X-RAY BACKGROUND, 1989, 296 : 401 - 404
  • [24] Impact assessment of breast glandularity on relative biological effectiveness of low energy IORT X-rays through Monte Carlo simulation
    Shamsabadi, Reza
    Baghani, Hamid Reza
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2021, 208
  • [25] A multiscale Monte Carlo simulation of irradiating a typical-size apple by low-energy X-rays and electron beams
    Rafiepour, Payman
    Sina, Sedigheh
    Mortazavi, Seyed Mohammad Javad
    RADIATION PHYSICS AND CHEMISTRY, 2023, 212
  • [26] Monte Carlo Analysis of the Influence of Different Packaging on MOSFET Energy Response to X-rays and Gamma Radiation
    Stankovic, S. J.
    Ilic, R. D.
    Zivanovic, M.
    Jankovic, K. S.
    Loncar, B.
    ACTA PHYSICA POLONICA A, 2012, 122 (04) : 655 - 658
  • [27] Energy resolution of xenon proportional counters: Monte Carlo and experimental results for 5.9 keV x-rays
    Rachinhas, PJBM
    Dias, THVT
    Santos, FP
    Stauffer, AD
    Conde, CAN
    1995 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD, VOLS 1-3, 1996, : 90 - 92
  • [28] A Comparison of Protons versus Gamma X-Rays in Producing Patient Radiographs: A Monte Carlo Study
    Depauw, N.
    Taranenko, V.
    Danto, S.
    Sorin, F.
    Fink, Y.
    Seco, J.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [29] Bulk substrate porosity verification by applying Monte Carlo modeling and Castaing's formula using energy-dispersive x-rays
    Yung, Lai Chin
    Fei, Cheong Choke
    Mandeep, Jit Singh
    Amin, Nowshad
    Lai, Khin Wee
    JOURNAL OF ELECTRONIC IMAGING, 2015, 24 (06)
  • [30] An investigation of backscatter factors for kilovoltage x-rays: a comparison between Monte Carlo simulations and Gafchromic EBT film measurements
    Kim, J.
    Hill, R.
    Mackonis, E. Claridge
    Kuncic, Z.
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (03): : 783 - 797