Peri-implant bone changes following tooth extraction, immediate placement and loading of implants in the edentulous maxilla

被引:31
作者
Barbier, Lieven [1 ]
Abeloos, Johan [2 ]
De Clercq, Calix [2 ]
Jacobs, Reinhilde [3 ]
机构
[1] Katholieke Univ Leuven, Sint Jan Hosp, Training Ctr Dent Students, B-8000 Brugge, Belgium
[2] Sint Jan Hosp, Dept Maxillofacial Surg, B-8000 Brugge, Belgium
[3] Katholieke Univ Leuven, Fac Med, Oral Imaging Ctr, B-3000 Louvain, Belgium
关键词
Dental implant; Marginal bone level; Maxilla; Fibre-reinforced provisional fixed prosthesis; CoCr-fixed prosthesis; Immediate placement; Immediate loading; DENTAL IMPLANTS; SOCKETS; SITES; DOG;
D O I
10.1007/s00784-011-0617-9
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The aim of this study was to clinically and radiographically evaluate peri-implant bone level changes after rehabilitation of a fully edentulous maxilla by placement of six implants in either fresh extraction sites or healed edentulous ridges up till 18 months after implant placement. Twenty patients with a terminal dentition in the maxillae (11 men, 9 women) received a total of 120 OsseoSpeedA (R) implants; 118 implants could be loaded immediately of which 59 were placed in extraction sockets and 59 were placed in healed sites. Within 24 h after surgery, all patients received a chairside-assembled, fibre-reinforced temporary fixed prosthetic reconstruction in occlusion. Six months post-surgery, final screw-retained CoCr (15) or Ti (5) computer numerical control-milled and acrylic-veneered frameworks were placed directly at implant level without interposing abutments. Intraoral radiographs were taken 6 and 18 months after implant placement. Implant survival rate was 100%. Mean marginal bone level was located on average -0.35 mm below the reference point (standard deviation 0.29, range -1.20 to +0.02 mm) 18 months after loading. Whether implants were placed in healed bone sites or fresh extraction sockets did not significantly affect the bone level changes. Furthermore, the use of either CoCr or Ti at the implant level did not significantly affect marginal bone loss. Within the limits of this prospective clinical trial, results seem to indicate that immediate placement and occlusal loading of five to six implants in the edentulous maxilla can be carried out successfully. Whether or not those implants are placed in fresh extraction sockets does not seem to alter the outcome. The present data show a successful 1-year outcome of a treatment protocol involving tooth extraction immediately combined with implant placement and loading.
引用
收藏
页码:1061 / 1070
页数:10
相关论文
共 27 条
[1]  
Adrianssens P, 2001, APPL OSSEOINTEGRATIO, V2, P17
[2]   OSSEOINTEGRATED TITANIUM IMPLANTS - REQUIREMENTS FOR ENSURING A LONG-LASTING, DIRECT BONE-TO-IMPLANT ANCHORAGE IN MAN [J].
ALBREKTSSON, T ;
BRANEMARK, PI ;
HANSSON, HA ;
LINDSTROM, J .
ACTA ORTHOPAEDICA SCANDINAVICA, 1981, 52 (02) :155-170
[3]  
Albrektsson T, 1993, Int J Prosthodont, V6, P95
[4]  
Allen PF, 2003, J CAN DENT ASSOC, V69, p662a
[5]   Dimensional ridge alterations following tooth extraction.: An experimental study in the dog [J].
Araújo, MG ;
Lindhe, J .
JOURNAL OF CLINICAL PERIODONTOLOGY, 2005, 32 (02) :212-218
[6]   Ridge alterations following implant placement in fresh extraction sockets:: an experimental study in the dog [J].
Araújo, MG ;
Sukekava, F ;
Wennström, JL ;
Lindhe, J .
JOURNAL OF CLINICAL PERIODONTOLOGY, 2005, 32 (06) :645-652
[7]  
Atieh MA, 2010, INT J ORAL MAX IMPL, V25, P401
[8]   Hard-tissue alterations following immediate implant placement in extraction sites [J].
Botticelli, D ;
Berglundh, T ;
Lindhe, J .
JOURNAL OF CLINICAL PERIODONTOLOGY, 2004, 31 (10) :820-828
[9]  
BRUNSKI J B, 1992, Clinical Materials, V10, P153, DOI 10.1016/0267-6605(92)90049-Y
[10]   Immediate functional loading of TiOblast dental implants in full-arch edentulous maxillae: a 3-year prospective study [J].
Collaert, Bruno ;
De Bruyn, Hugo .
CLINICAL ORAL IMPLANTS RESEARCH, 2008, 19 (12) :1254-1260