Automated Assessment of Drusen Using Three-Dimensional Spectral-Domain Optical Coherence Tomography

被引:18
|
作者
Iwama, Daisuke
Hangai, Masanori [1 ]
Ooto, Sotaro
Sakamoto, Atsushi
Nakanishi, Hideo
Fujimura, Takashi [2 ]
Domalpally, Amitha [3 ]
Danis, Ronald P. [3 ]
Yoshimura, Nagahisa
机构
[1] Kyoto Univ, Grad Sch Med, Dept Ophthalmol & Visual Sci, Sakyo Ku, Kyoto 6068507, Japan
[2] Topcon Corp, Tokyo, Japan
[3] Univ Wisconsin, Dept Ophthalmol & Visual Sci, Fundus Photograph Reading Ctr, Madison, WI USA
基金
日本学术振兴会;
关键词
AGE-RELATED MACULOPATHY; MACULAR DEGENERATION; SIGNAL STRENGTH; SEVERITY SCALE; NATURAL COURSE; SD-OCT; RISK; SEGMENTATION; PERFORMANCE; PATHOLOGY;
D O I
10.1167/iovs.11-8103
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To compare automated assessment of macular drusen delineated by the authors' originally developed algorithm on three-dimensional (3D) spectral-domain optical coherence tomography (SD-OCT) with the assessment by certified graders on color fundus photographs in nonneovascular age-related macular degeneration (AMD). METHODS. Automated assessment of macular drusen was performed using raster scan by 3D OCT scans in 18 eyes with nonneovascular AMD with at least one large druse (>= 125 mu m) and predominantly soft indistinct drusen. Drusen was defined as the regions that have the distance between the retinal pigment epithelium and calculated Bruch's membrane lines > predefined threshold distances. The agreement was assessed on maximum drusen size and drusen area within grid between 3D SD-OCT and color fundus photographs, and false-negative and false-positive drusen at each threshold distance. RESULTS. There was agreement or agreement within one step in all eyes in maximum drusen size, and 15 (83.3%) of the eyes in the drusen area, except 6 pixels, regardless of threshold distances. However, the number of eyes with exact agreement in the drusen area increased when the threshold distances were smaller than 4 pixels. In the three cases with disagreement in the drusen area, false-negative drusen on 3D SD-OCT were characterized by being small in area and height. CONCLUSIONS. Automated assessment of drusen parameters based on the authors' algorithm on 3D SD-OCT, which was limited by the poor detection ability of small drusen, showed good agreement with the assessment by certified graders on color fundus photography in these subjects. (Invest Ophthalmol Vis Sci. 2012;53:1576-1583) DOI:10.1167/iovs.11-8103
引用
收藏
页码:1576 / 1583
页数:8
相关论文
共 50 条
  • [41] Automated quantitative assessment of three-dimensional bioprinted hydrogel scaffolds using optical coherence tomography
    Wang, Ling
    Xu, Mingen
    Zhang, LieLie
    Zhou, QingQing
    Luo, Li
    BIOMEDICAL OPTICS EXPRESS, 2016, 7 (03): : 894 - 910
  • [42] Structural and optical characterization of banknotes using spectral-domain optical coherence tomography
    Wang, Lei
    Wu, Di
    Yv, Siyi
    Wang, Chengming
    Guang, Xiaoli
    Shi, Gaojun
    Yan, Yuwen
    Xie, Lanchi
    Huang, Wei
    Li, Zhigang
    Gao, Shuhui
    Zhang, Ning
    JOURNAL OF FORENSIC SCIENCES, 2022, 67 (05) : 2073 - 2081
  • [43] Spectral-domain optical coherence tomography: Removal of autocorrelation using an optical switch
    Ai, J
    Wang, LHV
    APPLIED PHYSICS LETTERS, 2006, 88 (11)
  • [44] In-vivo high resolution imaging of optic nerve head drusen using spectral-domain Optical Coherence Tomography
    Murthy R.K.
    Storm L.
    Grover S.
    Brar V.S.
    Chalam K.V.
    BMC Medical Imaging, 10 (1)
  • [45] Anterior Segment Biometry Using Spectral-Domain Optical Coherence Tomography
    Aptel, Florent
    Chiquet, Christophe
    Gimbert, Aurelie
    Romanet, Jean-Paul
    Thuret, Gilles
    Gain, Philippe
    Campolmi, Nelly
    JOURNAL OF REFRACTIVE SURGERY, 2014, 30 (05) : 354 - +
  • [46] Differentiation of Parapapillary Atrophy Using Spectral-Domain Optical Coherence Tomography
    Kim, Mijin
    Kim, Tae-Woo
    Weinreb, Robert N.
    Lee, Eun Ji
    OPHTHALMOLOGY, 2013, 120 (09) : 1790 - 1797
  • [47] Change in Drusen Area Over Time Compared Using Spectral-Domain Optical Coherence Tomography and Color Fundus Imaging
    Gregori, Giovanni
    Yehoshua, Zohar
    Garcia Filho, Carlos Alexandre de Amorim
    Sadda, SriniVas R.
    Nunes, Renata Portella
    Feuer, William J.
    Rosenfeld, Philip J.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (11) : 7662 - 7668
  • [48] Progression rate in glaucoma using spectral-domain optical coherence tomography
    Lee, Y.
    ACTA OPHTHALMOLOGICA, 2014, 92
  • [49] Real spectral-domain optical coherence tomography using a superluminescent diode
    Kim, J
    Choi, C
    Soh, KS
    Ho, DS
    Kim, BM
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2005, 47 (02) : 375 - 379
  • [50] SPECTRAL DOMAIN OPTICAL COHERENCE TOMOGRAPHY CHARACTERISTICS OF CUTICULAR DRUSEN
    Leng, Theodore
    Rosenfeld, Philip J.
    Gregori, Giovanni
    Puliafito, Carmen A.
    Punjabi, Omar S.
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2009, 29 (07): : 988 - 993