Automated Assessment of Drusen Using Three-Dimensional Spectral-Domain Optical Coherence Tomography

被引:18
|
作者
Iwama, Daisuke
Hangai, Masanori [1 ]
Ooto, Sotaro
Sakamoto, Atsushi
Nakanishi, Hideo
Fujimura, Takashi [2 ]
Domalpally, Amitha [3 ]
Danis, Ronald P. [3 ]
Yoshimura, Nagahisa
机构
[1] Kyoto Univ, Grad Sch Med, Dept Ophthalmol & Visual Sci, Sakyo Ku, Kyoto 6068507, Japan
[2] Topcon Corp, Tokyo, Japan
[3] Univ Wisconsin, Dept Ophthalmol & Visual Sci, Fundus Photograph Reading Ctr, Madison, WI USA
基金
日本学术振兴会;
关键词
AGE-RELATED MACULOPATHY; MACULAR DEGENERATION; SIGNAL STRENGTH; SEVERITY SCALE; NATURAL COURSE; SD-OCT; RISK; SEGMENTATION; PERFORMANCE; PATHOLOGY;
D O I
10.1167/iovs.11-8103
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To compare automated assessment of macular drusen delineated by the authors' originally developed algorithm on three-dimensional (3D) spectral-domain optical coherence tomography (SD-OCT) with the assessment by certified graders on color fundus photographs in nonneovascular age-related macular degeneration (AMD). METHODS. Automated assessment of macular drusen was performed using raster scan by 3D OCT scans in 18 eyes with nonneovascular AMD with at least one large druse (>= 125 mu m) and predominantly soft indistinct drusen. Drusen was defined as the regions that have the distance between the retinal pigment epithelium and calculated Bruch's membrane lines > predefined threshold distances. The agreement was assessed on maximum drusen size and drusen area within grid between 3D SD-OCT and color fundus photographs, and false-negative and false-positive drusen at each threshold distance. RESULTS. There was agreement or agreement within one step in all eyes in maximum drusen size, and 15 (83.3%) of the eyes in the drusen area, except 6 pixels, regardless of threshold distances. However, the number of eyes with exact agreement in the drusen area increased when the threshold distances were smaller than 4 pixels. In the three cases with disagreement in the drusen area, false-negative drusen on 3D SD-OCT were characterized by being small in area and height. CONCLUSIONS. Automated assessment of drusen parameters based on the authors' algorithm on 3D SD-OCT, which was limited by the poor detection ability of small drusen, showed good agreement with the assessment by certified graders on color fundus photography in these subjects. (Invest Ophthalmol Vis Sci. 2012;53:1576-1583) DOI:10.1167/iovs.11-8103
引用
收藏
页码:1576 / 1583
页数:8
相关论文
共 50 条
  • [31] In-vivo mapping of drusen by fundus autofluorescence and spectral-domain optical coherence tomography imaging
    Arno P. Göbel
    Monika Fleckenstein
    Tjebo F. C. Heeren
    Frank G. Holz
    Steffen Schmitz-Valckenberg
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2016, 254 : 59 - 67
  • [32] In-vivo mapping of drusen by fundus autofluorescence and spectral-domain optical coherence tomography imaging
    Goebel, Arno P.
    Fleckenstein, Monika
    Heeren, Tjebo F. C.
    Holz, Frank G.
    Schmitz-Valckenberg, Steffen
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2016, 254 (01) : 59 - 67
  • [33] Macular drusen in Fuchs endothelial corneal dystrophy: a retrospective study using spectral-domain optical coherence tomography
    Matthaei, Mario
    Elsner, Elena
    Caramoy, Albert
    Adler, Werner
    Siebelmann, Sebastian E.
    Schaub, Friederike
    Guo, Yongwei
    Bachmann, Bjoern
    Cursiefen, Claus
    Heindl, Ludwig M.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [34] Short-Term Changes of Basal Laminar Drusen on Spectral-Domain Optical Coherence Tomography
    van de Ven, Johannes P. H.
    Boon, Camiel J. F.
    Smailhodzic, Dzenita
    Lechanteur, Yara T. E.
    den Hollander, Anneke I.
    Hoyng, Carel B.
    Theelen, Thomas
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2012, 154 (03) : 560 - 567
  • [35] Clinical Assessment of Mirror Artifacts in Spectral-Domain Optical Coherence Tomography
    Ho, Joseph
    Castro, Dinorah P. E.
    Castro, Leonardo C.
    Chen, Yueli
    Liu, Jonathan
    Mattox, Cynthia
    Krishnan, Chandrasekharan
    Fujimoto, James G.
    Schuman, Joel S.
    Duker, Jay S.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (07) : 3714 - 3720
  • [36] Assessment of corneal layers thickness with spectral-domain optical coherence tomography
    Segura, F.
    de la Fuente, C. Lopez
    Sachez-Cano, A.
    Orduna, E.
    Del Buey, M.
    Pinilla, I.
    ACTA OPHTHALMOLOGICA, 2015, 93
  • [37] Automated Detection of Schlemm's Canal in Spectral-Domain Optical Coherence Tomography
    Tom, Manu
    Ramakrishnan, Vignesh
    van Oterendorp, Christian
    Deserno, Thomas M.
    MEDICAL IMAGING 2015: COMPUTER-AIDED DIAGNOSIS, 2015, 9414
  • [38] Macula mapping and simultaneous acquisition of sectional and fundus ophthalmic images with three-dimensional spectral-domain optical coherence tomography
    Jiao, S
    Knighton, R
    Gregori, G
    Huang, X
    Puliafito, CA
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [39] Automated Analysis of Anterior Chamber Inflammation by Spectral-Domain Optical Coherence Tomography
    Sharma, Sumit
    Lowder, Careen Y.
    Vasanji, Amit
    Baynes, Kimberly
    Kaiser, Peter K.
    Srivastava, Sunil K.
    OPHTHALMOLOGY, 2015, 122 (07) : 1464 - 1470
  • [40] In Vivo Three-Dimensional Characterization of the Healthy Human Lamina Cribrosa With Adaptive Optics Spectral-Domain Optical Coherence Tomography
    Nadler, Zach
    Wang, Bo
    Schuman, Joel S.
    Ferguson, R. Daniel
    Patel, Ankit
    Hammer, Daniel X.
    Bilonick, Richard A.
    Ishikawa, Hiroshi
    Kagemann, Larry
    Sigal, Ian A.
    Wollstein, Gadi
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (10) : 6459 - 6466