Automated Assessment of Drusen Using Three-Dimensional Spectral-Domain Optical Coherence Tomography

被引:18
|
作者
Iwama, Daisuke
Hangai, Masanori [1 ]
Ooto, Sotaro
Sakamoto, Atsushi
Nakanishi, Hideo
Fujimura, Takashi [2 ]
Domalpally, Amitha [3 ]
Danis, Ronald P. [3 ]
Yoshimura, Nagahisa
机构
[1] Kyoto Univ, Grad Sch Med, Dept Ophthalmol & Visual Sci, Sakyo Ku, Kyoto 6068507, Japan
[2] Topcon Corp, Tokyo, Japan
[3] Univ Wisconsin, Dept Ophthalmol & Visual Sci, Fundus Photograph Reading Ctr, Madison, WI USA
基金
日本学术振兴会;
关键词
AGE-RELATED MACULOPATHY; MACULAR DEGENERATION; SIGNAL STRENGTH; SEVERITY SCALE; NATURAL COURSE; SD-OCT; RISK; SEGMENTATION; PERFORMANCE; PATHOLOGY;
D O I
10.1167/iovs.11-8103
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To compare automated assessment of macular drusen delineated by the authors' originally developed algorithm on three-dimensional (3D) spectral-domain optical coherence tomography (SD-OCT) with the assessment by certified graders on color fundus photographs in nonneovascular age-related macular degeneration (AMD). METHODS. Automated assessment of macular drusen was performed using raster scan by 3D OCT scans in 18 eyes with nonneovascular AMD with at least one large druse (>= 125 mu m) and predominantly soft indistinct drusen. Drusen was defined as the regions that have the distance between the retinal pigment epithelium and calculated Bruch's membrane lines > predefined threshold distances. The agreement was assessed on maximum drusen size and drusen area within grid between 3D SD-OCT and color fundus photographs, and false-negative and false-positive drusen at each threshold distance. RESULTS. There was agreement or agreement within one step in all eyes in maximum drusen size, and 15 (83.3%) of the eyes in the drusen area, except 6 pixels, regardless of threshold distances. However, the number of eyes with exact agreement in the drusen area increased when the threshold distances were smaller than 4 pixels. In the three cases with disagreement in the drusen area, false-negative drusen on 3D SD-OCT were characterized by being small in area and height. CONCLUSIONS. Automated assessment of drusen parameters based on the authors' algorithm on 3D SD-OCT, which was limited by the poor detection ability of small drusen, showed good agreement with the assessment by certified graders on color fundus photography in these subjects. (Invest Ophthalmol Vis Sci. 2012;53:1576-1583) DOI:10.1167/iovs.11-8103
引用
收藏
页码:1576 / 1583
页数:8
相关论文
共 50 条
  • [1] Intraoperative Use of Three-Dimensional Spectral-Domain Optical Coherence Tomography
    Ide, Takeshi
    Wang, Jianhua
    Tao, Aizhu
    Leng, Theodore
    Kymionis, George D.
    O'Brien, Terrence P.
    Yoo, Sania H.
    OPHTHALMIC SURGERY LASERS & IMAGING, 2010, 41 (02) : 250 - 254
  • [2] Performance of Drusen Detection by Spectral-Domain Optical Coherence Tomography
    Schlanitz, Ferdinand G.
    Ahlers, Christian
    Sacu, Stefan
    Schuetze, Christopher
    Rodriguez, Marcos
    Schriefl, Sabine
    Golbaz, Isabelle
    Spalek, Tobias
    Stock, Geraldine
    Schmidt-Erfurth, Ursula
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (12) : 6715 - 6721
  • [3] Three-Dimensional Evaluation of the Lamina Cribrosa Using Spectral-Domain Optical Coherence Tomography in Glaucoma
    Lee, Eun Ji
    Kim, Tae-Woo
    Weinreb, Robert N.
    Suh, Min Hee
    Kang, Myungjoo
    Park, Ki Ho
    Kim, Seok Hwan
    Kim, Dong Myung
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2012, 53 (01) : 198 - 204
  • [4] Detection of a microrip using spectral-domain optical coherence tomography with three-dimensional image reconstruction
    Koizumi, Hideki
    Spaide, Richard F.
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2007, 27 (08): : 1152 - 1153
  • [5] Quantification of a three-dimensional velocity vector using spectral-domain Doppler optical coherence tomography
    Ahn, Yeh-Chan
    Jung, Woonggyu
    Chen, Zhongping
    OPTICS LETTERS, 2007, 32 (11) : 1587 - 1589
  • [6] Three-Dimensional Spectral-Domain Optical Coherence Tomography Data Analysis for Glaucoma Detection
    Xu, Juan
    Ishikawa, Hiroshi
    Wollstein, Gadi
    Bilonick, Richard A.
    Folio, Lindsey S.
    Nadler, Zach
    Kagemann, Larry
    Schuman, Joel S.
    PLOS ONE, 2013, 8 (02):
  • [7] Three-dimensional evaluation of vitreomacular traction and epiretinal membrane using spectral-domain optical coherence tomography
    Koizumi, Hideki
    Spaide, Richard F.
    Fisher, Yale L.
    Freund, K. Bailey
    Klancnik, James M., Jr.
    Yannuzzi, Lawrence A.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2008, 145 (03) : 509 - 517
  • [8] Three dimensional tracking for volumetric spectral-domain optical coherence tomography
    Maguluri, Gopi
    Mujat, Mircea
    Park, B. H.
    Kim, K. H.
    Sun, Wei
    Iftimia, N. V.
    Ferguson, R. Daniel
    Hammer, Daniel X.
    Chen, Teresa C.
    De Boer, Johannes F.
    OPTICS EXPRESS, 2007, 15 (25) : 16808 - 16817
  • [9] Three-Dimensional Imaging of Macular Inner Structures in Glaucoma by Using Spectral-Domain Optical Coherence Tomography
    Kotera, Yuriko
    Hangai, Masanori
    Hirose, Fumitaka
    Mori, Satoshi
    Yoshimura, Nagahisa
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (03) : 1412 - 1421
  • [10] Three-Dimensional Automated Choroidal Volume Assessment on Standard Spectral-Domain Optical Coherence Tomography and Correlation With the Level of Diabetic Macular Edema
    Gerendas, Bianca S.
    Waldstein, Sebastian M.
    Simader, Christian
    Deak, Gabor
    Hajnajeeb, Bilal
    Zhang, Li
    Bogunovic, Hrvoje
    Abramoff, Michael D.
    Kundi, Michael
    Sonka, Milan
    Schmidt-Erfurth, Ursula
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2014, 158 (05) : 1039 - 1048