摘要
Objectives: Cone Beam Computerized Tomography (CBCT) allows the possibility of modifying some of the diagnostic tools used in orthodontics, such as cephalometry. The first step must be to study the characteristics of these devices in terms of accuracy and reliability of the most commonly used landmarks. The aims were 1- To assess intra and inter-observer reliability in the location of anatomical landmarks belonging to hard tissues of the skull in images taken with a CBCT device, 2- To determine which of those landmarks are more vs. less reliable and 3- To introduce planes of reference so as to create cephalometric analyses appropriated to the 3D reality. Study design: Fifteen patients who had a CBCT (i-CAT (R)) as a diagnostic register were selected. To assess the reproducibility on landmark location and the differences in the measurements of two observers at different times, 41 landmarks were defined on the three spatial axes (X,Y,Z) and located. 3.690 measurements were taken and, as each determination has 3 coordinates, 11.070 data were processed with SPSS (R) statistical package. To discover the reproducibility of the method on landmark location, an ANOVA was undertaken using two variation factors: time (t1, t2 and t3) and observer (Ob1 and Ob2) for each axis (X, Y and Z) and landmark. The order of the CBCT scans submitted to the observers (Ob1, Ob2) at t1, t2, and t3, were different and randomly allocated. Multiple comparisons were undertaken using the Bonferroni test. The intra- and inter-examiner ICC's were calculated. Results: Intra- and inter- examiner reliability was high, both being ICC >= 0.99, with the best frequency on axis Z. Conclusions: The most reliable landmarks were: Nasion, Sella, Basion, left Porion, point A, anterior nasal spine, Pogonion, Gnathion, Menton, frontozygomatic sutures, first lower molars and upper and lower incisors. Those with less reliability were the supraorbitals, right zygion and posterior nasal spine.
引用
收藏
页码:E678 / E688
页数:11
相关论文
共 50 条
  • [41] Accuracy and precision of 3D cephalometric landmarks from biorthogonal plain film x-rays
    Dean, D
    Palomo, M
    Subramanyan, K
    Hans, MG
    Broadbent, BH
    Moullas, A
    Macaraeg, O
    IMAGE DISPLAY - MEDICAL IMAGING 1998, 1998, 3335 : 50 - 58
  • [42] In vivo comparison of MRI- and CBCT-based 3D cephalometric analysis: beginning of a non-ionizing diagnostic era in craniomaxillofacial imaging?
    Juerchott, Alexander
    Freudlsperger, Christian
    Weber, Dorothea
    Jende, Johann M. E.
    Saleem, Muhammad Abdullah
    Zingler, Sebastian
    Lux, Christopher J.
    Bendszus, Martin
    Heiland, Sabine
    Hilgenfeld, Tim
    EUROPEAN RADIOLOGY, 2020, 30 (03) : 1488 - 1497
  • [43] A comparison of two-dimensional radiography and three-dimensional computed tomography in angular cephalometric measurements
    Nalcaci, R.
    Ozturk, F.
    Sokucu, O.
    DENTOMAXILLOFACIAL RADIOLOGY, 2010, 39 (02) : 100 - 106
  • [45] 3D CBCT McNamara's cephalometric analysis in an adult southern Chinese population
    Wong, R. W. K.
    Chau, A. C. M.
    Haegg, U.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2011, 40 (09) : 920 - 925
  • [46] Three-dimensional cephalometric norms of Chinese adults in Hong Kong with balanced facial profile
    Cheung, Lim Kwong
    Chan, Yin Man
    Jayaratne, Yasas S. N.
    Lo, John
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2011, 112 (02): : E56 - E73
  • [47] Reproducibility of maxillofacial landmark identification on three-dimensional cone-beam computed tomography images of patients with mandibular prognathism Comparative study of a tentative method and traditional cephalometric analysis
    Fuyamada, Mariko
    Shibata, Momoko
    Nawa, Hiroyuki
    Yoshida, Kazuhito
    Kise, Yoshitaka
    Katsumata, Akitoshi
    Ariji, Eiichiro
    Goto, Shigemi
    ANGLE ORTHODONTIST, 2014, 84 (06) : 966 - 973
  • [48] 3D cephalometric analysis obtained from computed tomography. Review of the literature
    Rossini, Giulia
    Cavallini, Costanza
    Cassetta, Michele
    Barbato, Ersilia
    ANNALI DI STOMATOLOGIA, 2011, 2 (3-4) : 31 - 39
  • [49] Cone-Beam Computed Tomography-Based Three-Dimensional McNamara Cephalometric Analysis
    Goncalves dos Santos, Rodrigo Mologni
    De Martino, Jose Mario
    Haiter Neto, Francisco
    Passeri, Luis Augusto
    JOURNAL OF CRANIOFACIAL SURGERY, 2018, 29 (04) : 895 - 899
  • [50] Development of a three-dimensional hand model using 3D stereophotogrammetry: Evaluation of landmark reproducibility
    Hoevenaren, Inge A.
    Maal, Thomas J. J.
    Krikken, E.
    de Haan, A. F. J.
    Berge, S. J.
    Ulrich, D. J. O.
    JOURNAL OF PLASTIC RECONSTRUCTIVE AND AESTHETIC SURGERY, 2015, 68 (05) : 709 - 716