Development and validation of a treatment planning system for small animal radiotherapy: SmART-Plan

被引:105
作者
van Hoof, Stefan J. [1 ]
Granton, Patrick V. [1 ]
Verhaegen, Frank [1 ,2 ]
机构
[1] Maastricht Univ, Med Ctr, GROW Sch Oncol & Dev Biol, Dept Radiat Oncol MAASTRO, NL-6201 BN Maastricht, Netherlands
[2] McGill Univ, Dept Oncol, Med Phys Unit, Montreal, PQ, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Small animals; Precision irradiation; Radiotherapy; Treatment planning system; Pre clinical studies; Cone beam CT; DOSE CALCULATIONS; DOSIMETRY;
D O I
10.1016/j.radonc.2013.10.003
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: Image-guided equipment for precision irradiation of small animals for pre-clinical radiotherapy research became recently available. To enable downscaled radiotherapy studies that can be translated into human radiotherapy knowledge, a treatment planning system for pre-clinical studies is required. Material and methods: A dedicated treatment planning system (SmART-Plan) for small animal radiotherapy studies was developed. It is based on Monte Carlo simulation of particle transport in an animal. The voxel geometry is derived from the onboard cone beam CT imaging panel. SmART-Plan was validated using radiochromic film (RCF) dosimetry in various phantoms: uniform, multislab and a realistic plasticized mouse geometry. Results: Good agreement was obtained between SmART-Plan dose calculations and RCF dose measurements in all phantoms. For various delivered plans agreement was obtained within 10% for the majority of the targeted dose region, with larger differences between 10% and 20% near the penumbra regions and for the smallest 1 mm collimator. Absolute depth and lateral dose distributions showed better agreement for 5 and 15-mm collimators than for a 1-mm collimator, indicating that accurate dose prediction for the smallest field sizes is difficult. Conclusion: SmART-Plan offers a useful dose calculation tool for pre-clinical small animal irradiation studies. (C) 2013 The Authors. Published by Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:361 / 366
页数:6
相关论文
共 14 条
  • [1] Aspradakis MM, 2010, IPEM REPORT, V103
  • [2] Kilovoltage beam Monte Carlo dose calculations in submillimeter voxels for small animal radiotherapy
    Bazalova, Magdalena
    Zhou, Hu
    Keall, Paul J.
    Graves, Edward E.
    [J]. MEDICAL PHYSICS, 2009, 36 (11) : 4991 - 4999
  • [3] Boone John M, 2004, Mol Imaging, V3, P149, DOI 10.1162/1535350042380326
  • [4] On the use of an analytic source model for dose calculations in precision image-guided small animal radiotherapy
    Granton, Patrick V.
    Verhaegen, Frank
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (10) : 3377 - 3395
  • [5] A combined dose calculation and verification method for a small animal precision irradiator based on onboard imaging
    Granton, Patrick V.
    Podesta, Mark
    Landry, Guillaume
    Nijsten, Sebastiaan
    Bootsma, Gregory
    Verhaegen, Frank
    [J]. MEDICAL PHYSICS, 2012, 39 (07) : 4155 - 4166
  • [6] Cone beam computerized tomography: the effect of calibration of the Hounsfield unit number to electron density on dose calculation accuracy for adaptive radiation therapy
    Hatton, Joan
    McCurdy, Boyd
    Greer, Peter B.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (15) : N329 - N346
  • [7] Implementation and commissioning of an integrated micro-CT/RT system with computerized independent jaw collimation
    Jensen, Michael D.
    Hrinivich, W. Thomas
    Jung, Jongho A.
    Holdsworth, David W.
    Drangova, Maria
    Chen, Jeff
    Wong, Eugene
    [J]. MEDICAL PHYSICS, 2013, 40 (08)
  • [8] AAPM protocol for 40-300 kV x-ray beam dosimetry in radiotherapy and radiobiology
    Ma, CM
    Coffey, CW
    DeWerd, LA
    Liu, C
    Nath, R
    Seltzer, SM
    Seuntjens, JP
    [J]. MEDICAL PHYSICS, 2001, 28 (06) : 868 - 893
  • [9] Commissioning a small-field biological irradiator using point, 2D, and 3D dosimetry techniques
    Newton, Joseph
    Oldham, Mark
    Thomas, Andrew
    Li, Yifan
    Adamovics, John
    Kirsch, David G.
    Das, Shiva
    [J]. MEDICAL PHYSICS, 2011, 38 (12) : 6754 - 6762
  • [10] A contemporary review of stereotactic radiotherapy: Inherent dosimetric complexities and the potential for detriment
    Taylor, Michael L.
    Kron, Tomas
    Franich, Rick D.
    [J]. ACTA ONCOLOGICA, 2011, 50 (04) : 483 - 508