High-quality brain perfusion SPECT images may be achieved with a high-speed recording using 360° CZT camera

被引:28
作者
Bordonne, Manon [1 ,2 ,3 ]
Chawki, Mohammad B. [1 ,2 ]
Marie, Pierre-Yves [1 ,2 ,4 ]
Zaragori, Timothee [5 ]
Roch, Veronique [1 ,2 ]
Grignon, Rachel [1 ,2 ]
Imbert, Laetitia [1 ,2 ,3 ,5 ]
Verger, Antoine [1 ,2 ,5 ]
机构
[1] Univ Lorraine, Dept Nucl Med, CHRU Nancy, F-54000 Nancy, France
[2] Univ Lorraine, Nancyclotep Imaging Platform, CHRU Nancy, F-54000 Nancy, France
[3] CHRU Nancy Brabois, Med Nucl, Allee Morvan, F-54500 Nancy, France
[4] Univ Lorraine, INSERM, UMR 1116 DCAC, F-54000 Nancy, France
[5] Univ Lorraine, IADI, INSERM U1254, F-54000 Nancy, France
关键词
CZT; Brain perfusion; SPECT; Image quality; Count sensitivity; EMISSION COMPUTED-TOMOGRAPHY; PERFORMANCE; EPILEPSY; PET; DEMENTIAS; DIAGNOSIS; PHANTOM;
D O I
10.1186/s40658-020-00334-7
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective The aim of this study was to compare brain perfusion SPECT obtained from a 360 degrees CZT and a conventional Anger camera. Methods The 360 degrees CZT camera utilizing a brain configuration, with 12 detectors surrounding the head, was compared to a 2-head Anger camera for count sensitivity and image quality on 30-min SPECT recordings from a brain phantom and from Tc-99m-HMPAO brain perfusion in 2 groups of 21 patients investigated with the CZT and Anger cameras, respectively. Image reconstruction was adjusted according to image contrast for each camera. Results The CZT camera provided more than 2-fold increase in count sensitivity, as compared with the Anger camera, as well as (1) lower sharpness indexes, giving evidence of higher spatial resolution, for both peripheral/central brain structures, with respective median values of 5.2%/3.7% versus 2.4%/1.9% for CZT and Anger camera respectively in patients (p < 0.01), and 8.0%/6.9% versus 6.2%/3.7% on phantom; and (2) higher gray/white matter contrast on peripheral/central structures, with respective ratio median values of 1.56/1.35 versus 1.11/1.20 for CZT and Anger camera respectively in patients (p < 0.05), and 2.57/2.17 versus 1.40/1.12 on phantom; and (3) no change in noise level. Image quality, scored visually by experienced physicians, was also significantly higher on CZT than on the Anger camera (+ 80%, p < 0.01), and all these results were unchanged on the CZT images obtained with only a 15 min recording time. Conclusion The 360 degrees CZT camera provides brain perfusion images of much higher quality than a conventional Anger camera, even with high-speed recordings, thus demonstrating the potential for repositioning brain perfusion SPECT to the forefront of brain imaging.
引用
收藏
页数:12
相关论文
共 40 条
[1]  
[Anonymous], 2013, DIAGNOSTIC STAT MANU, VFifth, P1000
[2]   The effect of object size on the sensitivity of single photon emission computed tomography: comparison of two CZT cardiac cameras and an Anger scintillation camera [J].
Bienenstock E.A. ;
Ennis M. .
EJNMMI Physics, 1 (1) :1-10
[3]   Tc-99m HMPAO SPECT in the differential diagnosis of the dementias with histopathologic confirmation [J].
Bonte, FJ ;
Harris, TS ;
Hynan, LS ;
Bigio, EH ;
White, CL .
CLINICAL NUCLEAR MEDICINE, 2006, 31 (07) :376-378
[4]  
Bordonne Manon, 2020, J Neuroradiol, V47, P180, DOI 10.1016/j.neurad.2019.11.002
[5]   Role of concordance between ictal-subtracted SPECT and PET in predicting long-term outcomes after epilepsy surgery [J].
Chandra, P. S. ;
Vaghania, Gaurang ;
Bal, Chandra Sekhar ;
Tripathi, Madhavi ;
Kuruwale, Nitesh ;
Arora, Amit ;
Garg, Ajay ;
Sarkar, Chitra ;
Diwedi, Rekha ;
Malviya, Shrividya ;
Padma, Vasantha ;
Tripathi, Manjari .
EPILEPSY RESEARCH, 2014, 108 (10) :1782-1789
[6]   Diagnostic performance of a semiconductor gamma-camera system as studied by multicenter registry [J].
Chikamori, Taishiro ;
Goto, Kenji ;
Hida, Satoshi ;
Miyagawa, Masao ;
Ishimura, Hayato ;
Uchida, Kenji ;
Fukuyama, Takaya ;
Mochizuki, Teruhito ;
Yamashina, Akira .
JOURNAL OF CARDIOLOGY, 2017, 69 (1-2) :449-455
[7]   Dedicated cardiac CZT SPECT is steadily moving to achieve its destiny [J].
Daou, Doumit .
JOURNAL OF NUCLEAR CARDIOLOGY, 2019, 26 (02) :453-455
[8]   First Experience DaTSCAN Imaging Using Cadmium-Zinc-Telluride Gamma Camera SPECT [J].
Farid, Karim ;
Queneau, Mathieu ;
Guernou, Mohamed ;
Lussato, David ;
Poullias, Xavier ;
Petras, Slavomir ;
Caillat-Vigneron, Nadine ;
Songy, Bernard .
CLINICAL NUCLEAR MEDICINE, 2012, 37 (08) :E211-E212
[9]   Feasibility study of a novel general purpose CZT-based digital SPECT camera: initial clinical results [J].
Goshen, Elinor ;
Beilin, Leonid ;
Stern, Eli ;
Kenig, Tal ;
Goldkorn, Ronen ;
Ben-Haim, Simona .
EJNMMI PHYSICS, 2018, 5
[10]   Overview on whole body CZT cameras: The key points for the physicist [J].
Imbert, L. .
MEDECINE NUCLEAIRE-IMAGERIE FONCTIONNELLE ET METABOLIQUE, 2018, 42 (03) :194-195