Flicker Defined Form Perimetry in Glaucoma Suspects with Normal Achromatic Visual Fields

被引:11
作者
Reznicek, Lukas [1 ]
Lamparter, Julia [2 ]
Vogel, Michaela [1 ]
Kampik, Anselm [1 ]
Hirneiss, Christoph [1 ]
机构
[1] Univ Munich, Dept Ophthalmol, D-80336 Munich, Germany
[2] Johannes Gutenberg Univ Mainz, Univ Med Ctr, Dept Ophthalmol, D-55122 Mainz, Germany
关键词
Early glaucoma; FDF perimetry; glaucoma; glaucoma suspects; HEP; SAP; DOUBLING TECHNOLOGY PERIMETRY; AUTOMATED PERIMETRY; OCULAR HYPERTENSION; PROGRESSION; EXPERIENCE; BLINDNESS; DECREASE; NUMBER;
D O I
10.3109/02713683.2014.957324
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background: To evaluate if repeated flicker-defined form (FDF) perimetry can detect visual field (VF) defects in glaucoma suspects with normal findings in achromatic standard automated perimetry (SAP). Methods: Patients with optic nerve heads (ONHs) or retinal nerve fiber layer (RNFL) findings clinically suspicious for glaucoma and normal SAP were enrolled. Patients underwent VF testing with FDF perimetry (Heidelberg Edge Perimetry, HEP) at two consecutive visits (HEP I and HEP II) and confocal scanning laser ophthalmoscopy with the Heidelberg Retina Tomograph (HRT). Abnormal HEP was defined by cluster-point analysis (CPA) and by the HEP specific glaucoma hemi-field test (GHT). Results were compared with an age-matched control group of healthy individuals. Results: In 65 eyes of 36 glaucoma suspects, the mean deviation (MD) in SAP was -0.9 +/- 1.3 dB. In HEP I and HEP II, mean MD was -3.6 +/- 3.0 and -3.3 +/- 3.7 dB, respectively (p = 0.276). The HRT assessed CDR was significantly correlated with the MD in HEP II (r = -0.281, p = 0.04). In HEP I, VF defects on CPA testing were found in 38 study eyes (58.5%). In HEP II, 34 eyes (51.8%) had VF defects on CPA testing. In 46 eyes of 46 age-matched healthy individuals in the control group, the mean MD was -0.2 +/- 1.1 and -1.6 +/- 2.3 dB in SAP and HEP testing, respectively. The FDF was abnormal in 21.7% in the control group compared to 58.5% in the glaucoma suspect group in HEP I. Conclusions: In more than half of the patients with ONHs or RNFLs clinically suspicious for glaucoma and normal SAP second FDF perimetry depicts VF defects.
引用
收藏
页码:683 / 689
页数:7
相关论文
共 26 条
  • [21] The number of people with glaucoma worldwide in 2010 and 2020
    Quigley, HA
    Broman, AT
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2006, 90 (03) : 262 - 267
  • [22] Learning effect of short-wave length automated perimetry in patients with ocular hypertension
    Rossetti, Luca
    Fogagnolo, Paolo
    Miglior, Stefano
    Centofanti, Marco
    Vetrugno, Michele
    Orzalesi, Nicola
    [J]. JOURNAL OF GLAUCOMA, 2006, 15 (05) : 399 - 404
  • [23] Full-threshold versus Swedish interactive threshold algorithm (SITA) in normal individuals undergoing automated perimetry for the first time
    Schimiti, RB
    Avelino, RR
    Kara-José, N
    Costa, VP
    [J]. OPHTHALMOLOGY, 2002, 109 (11) : 2084 - 2092
  • [24] Effect of cataract extraction on frequency doubling technology perimetry in patients with glaucoma
    Siddiqui, MAR
    Azuara-Blanco, A
    Neville, S
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2005, 89 (12) : 1569 - 1571
  • [25] Responses of Primate Retinal Ganglion Cells to Perimetric Stimuli
    Swanson, William H.
    Sun, Hao
    Lee, Barry B.
    Cao, Dingcai
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (02) : 764 - 771
  • [26] PROGRESSION OF DISK AND FIELD DAMAGE IN EARLY GLAUCOMA
    ZEYEN, TG
    CAPRIOLI, J
    [J]. ARCHIVES OF OPHTHALMOLOGY, 1993, 111 (01) : 62 - 65