A NOVEL METHOD FOR MEASURING ELECTROMECHANICAL DELAY OF THE VASTUS MEDIALIS OBLIQUUS AND VASTUS LATERALIS

被引:9
作者
Chen, Han-Yu [1 ]
Liau, Jiann-Jong [1 ]
Wang, Chung-Li [2 ]
Lai, Hung-Jen [3 ]
Jan, Mei-Hwa [1 ]
机构
[1] Natl Taiwan Univ, Grad Inst Phys Therapy, Coll Med, Taipei 100, Taiwan
[2] Natl Taiwan Univ, Coll Med, Dept Orthoped, Taipei 100, Taiwan
[3] Natl Yang Ming Univ, Inst Biomed Engn, Taipei 112, Taiwan
关键词
Ultrasonography; Electrical stimulation; Patellar movement; HUMAN SKELETAL-MUSCLE; IN-VIVO; ELECTRICAL-STIMULATION; NEUROMUSCULAR CONTROL; ACL RECONSTRUCTION; ELASTIC PROPERTIES; PATELLAR TRACKING; HUMAN TENDON; ULTRASOUND; FATIGUE;
D O I
10.1016/j.ultrasmedbio.2008.06.011
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Electromechanical delay (EMD) of the vastus medialis obliquus (VMO) and vastus lateralis (VL) is determined by measuring the interval between the time of onset of muscle activities and the time of onset of mechanical output. However, individual mechanical output of the VMO or the VI, cannot be obtained with the conventional method because of the knee extension force as the mechanical output. Therefore, the objective of the present study was to develop a new method for measuring EMD) of the VMO and VL individually. Twelve healthy, volunteers participated in the experiment. The motor point of the target muscle was electrically stimulated to evoke a muscle twitch. Simultaneously, the electrical stimulation signal was transmitted to ultrasound apparatus via the electrocardiography input channel. The ultrasound apparatus was used to capture the patellar movement elicited by the muscle twitch. EMD was measured from the onset or the electrical stimulation to the onset of patellar movement. The results showed that the intraclass correlation coefficients for the reproducibility of the EMD measurements of the VMO and VL were greater than 0.8. The EMDs of the VMO and VL were 18.3 +/- 2.2 ms and 24.8 +/- 5.8 ms, respectively,. This new method provides a more precise measurement of EMD in the VMO and VL than does the conventional method because of the use of patellar movement as the mechanical output.
引用
收藏
页码:14 / 20
页数:7
相关论文
共 32 条
[11]   Changes in the elastic properties of tendon structures following 20 days bed-rest in humans [J].
Kubo, K ;
Akima, H ;
Kouzaki, M ;
Ito, M ;
Kawakami, Y ;
Kanehisa, H ;
Fukunaga, T .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2000, 83 (06) :463-468
[12]   Effects of isometric training on the elasticity of human tendon structures in vivo [J].
Kubo, K ;
Kanehisa, H ;
Ito, M ;
Fukunaga, T .
JOURNAL OF APPLIED PHYSIOLOGY, 2001, 91 (01) :26-32
[13]   Strain measurements of rabbit achilles tendons by ultrasound [J].
Kuo, PL ;
Li, PC ;
Shun, CT ;
Lai, JS .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1999, 25 (08) :1241-1250
[14]   Elastic properties of tendon measured by two different approaches [J].
Kuo, PL ;
Li, PC ;
Li, ML .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2001, 27 (09) :1275-1284
[15]   The function of gastrocnemius as a knee flexor at selected knee and ankle angles [J].
Li, L ;
Landin, D ;
Grodesky, J ;
Myers, J .
JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2002, 12 (05) :385-390
[16]   Effects of neuromuscular training on the reaction time and electromechanical delay of the peroneus longus muscle [J].
Linford, CW ;
Hopkins, JT ;
Schulthies, SS ;
Freland, B ;
Draper, DO ;
Hunter, I .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2006, 87 (03) :395-401
[17]  
Maganaris CN, 2000, J EXP BIOL, V203, P751
[18]   Influence of tendon slack on electromechanical delay in the human medial gastrocnemius in vivo [J].
Muraoka, T ;
Muramatsu, T ;
Fukunaga, T ;
Kanehisa, H .
JOURNAL OF APPLIED PHYSIOLOGY, 2004, 96 (02) :540-544
[19]  
Perotto A.O., 2011, ANATOMICAL GUIDE ELE
[20]   Factors in fatigue during intermittent electrical stimulation of human skeletal muscle [J].
Russ, DW ;
Vandenborne, K ;
Binder-Macleod, SA .
JOURNAL OF APPLIED PHYSIOLOGY, 2002, 93 (02) :469-478