Reconstructing 3D x-ray CT images of polymer gel dosimeters using the zero-scan method

被引:2
|
作者
Kakakhel, M. B. [1 ,3 ]
Kairn, T. [1 ,2 ]
Kenny, J. [2 ]
Trapp, J. V. [1 ]
机构
[1] Queensland Univ Technol, Sch Chem Phys & Mech Engn, GPO Box 2434, Brisbane, Qld 4001, Australia
[2] Wesley Med Ctr, Premion Canc Care, Auchenflower, Qld 4066, Australia
[3] Pakistan Inst Engn & Appl Sci, Dept Phys & Appl Math DPAM, Islamabad 45650, Pakistan
关键词
RADIATION-DOSE DISTRIBUTIONS; COMPUTED-TOMOGRAPHY; RADIOTHERAPY;
D O I
10.1088/1742-6596/444/1/012091
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
In this study x-ray CT has been used to produce a 3D image of an irradiated PAGAT gel sample, with noise-reduction achieved using the 'zero-scan' method. The gel was repeatedly CT scanned and a linear fit to the varying Hounsfield unit of each pixel in the 3D volume was evaluated across the repeated scans, allowing a zero-scan extrapolation of the image to be obtained. To minimise heating of the CT scanner's x-ray tube, this study used a large slice thickness (1 cm), to provide image slices across the irradiated region of the gel, and a relatively small number of CT scans (63), to extrapolate the zero-scan image. The resulting set of transverse images shows reduced noise compared to images from the initial CT scan of the gel, without being degraded by the additional radiation dose delivered to the gel during the repeated scanning. The full, 3D image of the gel has a low spatial resolution in the longitudinal direction, due to the selected scan parameters. Nonetheless, important features of the dose distribution are apparent in the 3D x-ray CT scan of the gel. The results of this study demonstrate that the zero-scan extrapolation method can be applied to the reconstruction of multiple x-ray CT slices, to provide useful 2D and 3D images of irradiated dosimetry gels.
引用
收藏
页数:4
相关论文
共 50 条
  • [21] Recognition of lung nodules from X-ray CT images using 3D MRF models
    Takizawa, H
    Yamamoto, S
    Matsumoto, T
    Tateno, Y
    Iinuma, T
    Matsumoto, M
    CARS 2001: COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2001, 1230 : 570 - 575
  • [22] 3D Analysis of Coke Microstructure Using μ-X-ray CT
    Yamamoto, Yuichiro
    Kashiwaya, Yoshiaki
    Nishimura, Masaru
    Kubota, Masahiro
    TETSU TO HAGANE-JOURNAL OF THE IRON AND STEEL INSTITUTE OF JAPAN, 2009, 95 (02): : 103 - 111
  • [23] 3D X-ray scan visualization and analysis system
    Markelov, AA
    INTERNATIONAL CONFERENCE ON X-RAY AND NEUTRON CAPILLARY OPTICS, 2002, 4765 : 67 - 72
  • [24] Considerations for x-ray CT polymer gel dosimetry
    Jirasek, A.
    7TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY (IC3DDOSE), 2013, 444
  • [25] Establishment of numerical cracking constitutive models using 3D reconstruction and X-ray CT images of geomaterials
    Zhao, Zhi
    Zhou, Xiao-Ping
    INTERNATIONAL JOURNAL OF MECHANICAL SCIENCES, 2020, 183 (183)
  • [26] Automatic Postmortem Human Identification using Collarbone of X-ray and CT Scan Images
    Cho, Hanni
    Zin, Thi Thi
    Shinkawa, Norihiro
    Nishii, Ryuichi
    Hama, Hiromitsu
    2018 IEEE 7TH GLOBAL CONFERENCE ON CONSUMER ELECTRONICS (GCCE 2018), 2018, : 551 - 552
  • [27] A method for extracting lung lobe regions from 3D chest X-ray CT images based on 3D figure decomposition approach
    Mori, K.
    Nakada, Y.
    Kitasaka, T.
    Suenaga, Y.
    Takabatake, H.
    Natori, H.
    Mori, M.
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2007, 2 : S89 - S91
  • [28] POSTOPERATIVE 3D ANALYSIS BASED ON X-RAY IMAGES
    Vigneron, Lara
    Lawrenchuk, Mike
    Delport, Hendrik
    Beski, Danielle
    De Boodt, Sebastian
    PROCEEDINGS OF THE ASME INTERNATIONAL DESIGN ENGINEERING TECHNICAL CONFERENCES AND COMPUTERS AND INFORMATION IN ENGINEERING CONFERENCE, 2014, VOL 3, 2014,
  • [29] Automated 3D semantic segmentation of PCB X-ray CT images and netlist extraction
    Phoulady, Adrian
    Suleiman, Yara
    Choi, Hongbin
    May, Nicholas
    Shahbazmohamadi, Sina
    Tavousi, Pouya
    SCIENTIFIC REPORTS, 2025, 15 (01):
  • [30] A preliminary study of the novel application of normoxic polymer gel dosimeters for the measurement of CTDI on diagnostic x-ray CT scanners
    Hill, B
    Venning, AJ
    Baldock, C
    MEDICAL PHYSICS, 2005, 32 (06) : 1589 - 1597