Effect of bone quality and implant surgical technique on implant stability quotient (ISQ) value

被引:43
|
作者
Yoon, Hong-Gi [3 ]
Heo, Seong-Joo [1 ,2 ]
Koak, Jai-Young [1 ,2 ]
Kim, Seong-Kyun [1 ,2 ]
Lee, Su-Young [1 ,2 ]
机构
[1] Seoul Natl Univ, Sch Dent, Seoul Natl Univ Dent Hosp, Dept Prosthodont, Seoul 110768, South Korea
[2] Seoul Natl Univ, Sch Dent, Seoul Natl Univ Dent Hosp, Dent Res Inst, Seoul 110768, South Korea
[3] Seoul Natl Univ, Sch Dent, Dept Dent, Seoul 110768, South Korea
关键词
Compaction; Self-tapping; Tapping; Implant Stability Quotient (ISO) Resonance frequency analysis; Finite element analysis; RESONANCE FREQUENCY-ANALYSIS; OSSEOINTEGRATION;
D O I
10.4047/jap.2011.3.1.10
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
PURPOSE. This study investigated the influence of bone quality and surgical technique on the implant stability quotient (ISQ) Value. In addition, the influence of interfacial bone quality, directly surrounding the implant fixture, on the resonance frequency of the structure was also evaluated by the finite element analysis. MATERIALS AND METHODS. Two different types of bone (type 1 and type 2) were extracted and trimmed from pig rib bone. In each type of bone, the same implants were installed in three different ways: (1) Compaction, (2) Self-tapping, and (3) Tapping. The ISQ value was measured and analyzed to evaluate the influence of bone quality and surgical technique on the implant primary stability. For finite element analysis, a three dimensional implant fixture-bone structure was designed and the fundamental resonance frequency of the structure was measured with three different density of interfacial bone surrounding the implant fixture. RESULTS. In each group, the ISQ values were higher in type 1 bone than those in type 2 bone. Among three different insertion methods, the Tapping group showed the lowest ISQ value in both type 1 and type 2 bones. In both bone types, the Compaction groups showed slightly higher mean ISQ values than the Self-tapping groups, but the differences were not statistically significant. Increased interfacial bone density raised the resonance frequency value in the finite element analysis. CONCLUSION. Both bone quality and surgical technique have influence on the implant primary stability, and resonance frequency has a positive relation with the density of implant fixture-surrounding bone. [J Adv Prosthodont 2011;3:10-5]
引用
收藏
页码:10 / 15
页数:6
相关论文
共 50 条
  • [31] Heat generation during implant placement in low-density bone: effect of surgical technique, insertion torque and implant macro design
    Markovic, Aleksa
    Misic, Tijana
    Milicic, Biljana
    Luis Calvo-Guirado, Jose
    Aleksic, Zoran
    Dinic, Ana
    CLINICAL ORAL IMPLANTS RESEARCH, 2013, 24 (07) : 798 - 805
  • [32] Peroperative estimation of bone quality and primary dental implant stability
    Voumard, Benjamin
    Maquer, Ghislain
    Heuberger, Peter
    Zysset, Philippe K.
    Wolfram, Uwe
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2019, 92 : 24 - 32
  • [33] Effect of photobiomodulation therapy of overprepared dental implant bed on torque removal and implant stability quotient: an experimental study in sheep
    Xailani, Kocher K.
    Hamad, Shehab A.
    MINERVA DENTAL AND ORAL SCIENCE, 2024, 73 (02) : 96 - 101
  • [34] Investigation of the Influence of Roughness and Dental Implant Design on Primary Stability via Analysis of Insertion Torque and Implant Stability Quotient: An In Vitro Study
    Romero, Marta
    Herrero-Climent, Mariano
    Rios-Carrasco, Blanca
    Brizuela, Aritza
    Romero, Manuel Maria
    Gil, Javier
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (13)
  • [35] Effects of smoking on the bone alkaline phosphatase in peri-implant crevicular fluid and implant stability quotient around implants before loading
    Tuter, Gulay
    Yildirim, Arzu Zeynep
    Duman, Ayse Nurcan
    Aliyev, Behruz
    Atak-Yucel, Aysegul
    Oruklu, Nihan
    Kivrak, Elifcan
    ODONTOLOGY, 2022, 110 (03) : 596 - 604
  • [36] A simple mathematical model for the resonance frequency analysis of dental implant stability: Implant clamping quotient
    Argatov, Ivan
    Iantchenko, Alexei
    MECHANICS RESEARCH COMMUNICATIONS, 2019, 95 : 67 - 70
  • [37] The Effectiveness of Osseodensification Drilling versus the Conventional Surgical Technique on Implant Stability: A Clinical Trial
    Pereira, Joao Fontes
    Costa, Rosana
    Vasques, Miguel Nunes
    Relvas, Marta
    Braga, Ana Cristina
    Salazar, Filomena
    da Camara, Marco Infante
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (10)
  • [38] Insertion Torque Value and Implant Stability Quotient: Separate Evaluation and Correlation for Different Clinical Parameters
    Ferreira, Jose Joaquim Da Rocha
    Machado, Luis Filipe Meira
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2022, 37 (04) : 812 - 822
  • [39] Effects of smoking on the bone alkaline phosphatase in peri-implant crevicular fluid and implant stability quotient around implants before loading
    Gulay Tuter
    Arzu Zeynep Yildirim
    Ayse Nurcan Duman
    Behruz Aliyev
    Aysegul Atak-Yucel
    Nihan Oruklu
    Elifcan Kivrak
    Odontology, 2022, 110 : 596 - 604
  • [40] Influence of the surgical technique and surface roughness on the primary stability of an implant in artificial bone with a density equivalent to maxillary bone: a laboratory study
    Tabassum, Afsheen
    Meijer, Gert J.
    Wolke, Johannes G. C.
    Jansen, John A.
    CLINICAL ORAL IMPLANTS RESEARCH, 2009, 20 (04) : 327 - 332