Effect of bone quality and implant surgical technique on implant stability quotient (ISQ) value

被引:43
|
作者
Yoon, Hong-Gi [3 ]
Heo, Seong-Joo [1 ,2 ]
Koak, Jai-Young [1 ,2 ]
Kim, Seong-Kyun [1 ,2 ]
Lee, Su-Young [1 ,2 ]
机构
[1] Seoul Natl Univ, Sch Dent, Seoul Natl Univ Dent Hosp, Dept Prosthodont, Seoul 110768, South Korea
[2] Seoul Natl Univ, Sch Dent, Seoul Natl Univ Dent Hosp, Dent Res Inst, Seoul 110768, South Korea
[3] Seoul Natl Univ, Sch Dent, Dept Dent, Seoul 110768, South Korea
关键词
Compaction; Self-tapping; Tapping; Implant Stability Quotient (ISO) Resonance frequency analysis; Finite element analysis; RESONANCE FREQUENCY-ANALYSIS; OSSEOINTEGRATION;
D O I
10.4047/jap.2011.3.1.10
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
PURPOSE. This study investigated the influence of bone quality and surgical technique on the implant stability quotient (ISQ) Value. In addition, the influence of interfacial bone quality, directly surrounding the implant fixture, on the resonance frequency of the structure was also evaluated by the finite element analysis. MATERIALS AND METHODS. Two different types of bone (type 1 and type 2) were extracted and trimmed from pig rib bone. In each type of bone, the same implants were installed in three different ways: (1) Compaction, (2) Self-tapping, and (3) Tapping. The ISQ value was measured and analyzed to evaluate the influence of bone quality and surgical technique on the implant primary stability. For finite element analysis, a three dimensional implant fixture-bone structure was designed and the fundamental resonance frequency of the structure was measured with three different density of interfacial bone surrounding the implant fixture. RESULTS. In each group, the ISQ values were higher in type 1 bone than those in type 2 bone. Among three different insertion methods, the Tapping group showed the lowest ISQ value in both type 1 and type 2 bones. In both bone types, the Compaction groups showed slightly higher mean ISQ values than the Self-tapping groups, but the differences were not statistically significant. Increased interfacial bone density raised the resonance frequency value in the finite element analysis. CONCLUSION. Both bone quality and surgical technique have influence on the implant primary stability, and resonance frequency has a positive relation with the density of implant fixture-surrounding bone. [J Adv Prosthodont 2011;3:10-5]
引用
收藏
页码:10 / 15
页数:6
相关论文
共 50 条
  • [1] Effect of bone quality, implant design, and surgical technique on primary implant stability
    Karl, Matthias
    Grobecker-Karl, Tanja
    QUINTESSENCE INTERNATIONAL, 2018, 49 (03): : 189 - 198
  • [2] Implant Stability Quotient (ISQ) from surgery to prosthetic rehabilitation
    Sampaio-Fernandes, Manuel A.
    Pimentel, Luis Guilherme
    Marques, Nuno Mesquita
    Fernandes, Pedro Ferras
    Almeida, Paulo Julio
    Sampaio-Fernandes, Joao C.
    BIODENTAL ENGINEERING IV, 2018, : 21 - 24
  • [3] In Vitro Investigation of the Dependency Between Abutment Length and Implant Stability Quotient (ISQ) for Stability Measurements on Bone Anchored Hearing Implant Systems
    Hogsbro, Morten
    Agger, Andreas
    Johansen, Lars Vendelbo
    Gaihede, Michael
    OTOLOGY & NEUROTOLOGY, 2020, 41 (06) : 848 - 854
  • [4] Calculating ISQ Primary Stability of a Dental Implant through Micromotion
    Pammer, David
    PERIODICA POLYTECHNICA-MECHANICAL ENGINEERING, 2020, 64 (01): : 43 - 50
  • [5] Improvement in the Initial Implant Stability Quotient Through Use of a Modified Surgical Technique
    Diaz-Sanchez, Rosa-Maria
    Delgado-Munoz, Jose-Maria
    Hita-Iglesias, Pilar
    Pullen, Kyle T.
    Serrera-Figallo, Maria-Angeles
    Torres-Lagares, Daniel
    JOURNAL OF ORAL IMPLANTOLOGY, 2017, 43 (03) : 186 - 193
  • [6] The comparison between implant stability quotient and bone-implant contact revisited: an experiment in Beagle dog
    Manresa, Carolina
    Bosch, Manel
    Echeverria, Jose J.
    CLINICAL ORAL IMPLANTS RESEARCH, 2014, 25 (11) : 1213 - 1221
  • [7] Correlation between Periotest value and implant stability quotient: a systematic review
    Rodrigues, Alana Semenzin
    Neto, Clovis Lamartine de Moraes Melo
    Januzzi, Marcella Santos
    dos Santos, Daniela Micheline
    Goiato, Marcelo Coelho
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2024, 69 (01): : 1 - 10
  • [8] Relation between initial implant stability quotient and bone-implant contact percentage: an in vitro model study
    Huang, Heng-Li
    Tsai, Ming-Tzu
    Su, Kuo-Chih
    Li, Yu-Fen
    Hsu, Jui-Ting
    Chang, Chih-Han
    Fuh, Lih-Jyh
    Wu, Aaron Yu-Jen
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2013, 116 (05): : E356 - E361
  • [9] The relationship between initial implant stability quotient values and bone-to-implant contact ratio in the rabbit tibia
    Park, In-Phill
    Kim, Seong-Kyun
    Lee, Shin-Jae
    Lee, Joo-Hee
    JOURNAL OF ADVANCED PROSTHODONTICS, 2011, 3 (02) : 76 - 80
  • [10] Influence of surgical technique, implant shape and diameter on the primary stability in cancellous bone
    Bilhan, H.
    Geckili, O.
    Mumcu, E.
    Bozdag, E.
    Sunbuloglu, E.
    Kutay, O.
    JOURNAL OF ORAL REHABILITATION, 2010, 37 (12) : 900 - 907