An Update to a Novel Technique for Centering the Femoral Stem in Primary Total Hip Arthroplasty

被引:0
|
作者
Bono, Olivia J. [1 ]
Shields, John S. [2 ]
Schuett, Dustin J. [1 ]
Pinski, John [3 ]
Bono, James, V [4 ]
机构
[1] New England Baptist Hosp, Dept Orthopaed Surg, Boston, MA 02120 USA
[2] Wake Forest Baptist Hlth, Orthopaed Surg, Bermuda Run, NC USA
[3] Tufts Univ, Sch Med, Boston, MA 02111 USA
[4] New England Baptist Hosp, Dept Orthopaed Surg, Orthopaed, Boston, MA USA
来源
SURGICAL TECHNOLOGY INTERNATIONAL-INTERNATIONAL DEVELOPMENTS IN SURGERY AND SURGICAL RESEARCH | 2019年 / 35卷
关键词
SHAFT PERFORATION; ALIGNMENT; RESECTION;
D O I
暂无
中图分类号
R61 [外科手术学];
学科分类号
摘要
Careful surgical technique is a critical component of total hip arthroplasty. Femoral preparation and component positioning are vital to improving outcomes and preventing complications. Femoral preparation begins with creating an entry hole in the proximal femur. Various tools have been used for this purpose which resemble a "cookie cutter." An axial starter reamer, or awl, is then inserted through the entry hole in the proximal femur to aid in opening and centralizing the canal for sequential reaming or broaching. A novel technique was described previously which allows the awl to center itself in the canal with little risk of deviation from midline or cortical perforation. Since describing this technique in 2014, the senior surgeon has further modified the method of preparing the entry hole in the proximal femur. The surgeon now uses a 1/8 '' drill bit to penetrate the piriformis fossa, instead of a "cookie cutter" or osteotome. A 1/8 '' entry hole eliminates gaps between the bone and the implant, results in lateralization of the stem, and avoids varus malposition. We evaluated 300 primary hip arthroplasties by a single surgeon using one of the three techniques: traditional clockwise technique ( Group 1), our previously published novel counterclockwise technique (Group 2), and our updated novel technique (Group 3). While the deviation from midline of Group 3 did not differ significantly from Group 2, it was significantly less than the deviation from midline of Group 1 (p=00006). This simple updated technique enables the surgeon to avoid potential malalignment during femoral preparation.
引用
收藏
页数:4
相关论文
共 50 条
  • [21] Primary Total Hip Arthroplasty for Displaced Femoral Neck Fracture
    Watson, David
    Bostrom, Mathias
    Salvati, Eduardo
    Walcott-Sapp, Sarah
    Westrich, Geoffrey
    ORTHOPEDICS, 2008, 31 (10) : 990 - 990
  • [22] Dislocations and the femoral head size in primary total hip arthroplasty
    Hedlundh, U
    Ahnfelt, L
    Hybbinette, CH
    Wallinder, L
    Weckstrom, J
    Fredin, H
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1996, (333) : 226 - 233
  • [23] Intraoperative Measurement of Femoral Offset in Primary Total Hip Arthroplasty
    Iqbal, Shoaib
    Datir, Sandeep
    TECHNIQUES IN ORTHOPAEDICS, 2015, 30 (04) : E15 - E16
  • [24] Femoral head diameter considerations for primary total hip arthroplasty
    Girard, J.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2015, 101 (01) : S25 - S29
  • [25] Primary total hip arthroplasty with a retained intramedullary femoral nail
    Goosen, Jon H. M.
    Van Hellemondt, Gijs G.
    ACTA ORTHOPAEDICA BELGICA, 2013, 79 (01): : 114 - 116
  • [26] Isoelastic femoral component in primary cementless total hip arthroplasty
    Ali, MS
    Kumar, A
    INTERNATIONAL ORTHOPAEDICS, 2002, 26 (04) : 243 - 246
  • [27] Isoelastic femoral component in primary cementless total hip arthroplasty
    Salaman M. Ali
    A. Kumar
    International Orthopaedics, 2002, 26 : 243 - 246
  • [28] Total Hip Arthroplasty - An Update
    Knahr, K.
    Pospischill, M.
    JOURNAL FUR MINERALSTOFFWECHSEL, 2008, 15 : 36 - 39
  • [29] Lower reoperation rate for cemented femoral stem than for uncemented femoral stem in primary total hip arthroplasty following a displaced femoral neck fracture
    Andersen, Michelle F.
    Jakobsen, Thomas
    Bensen, Anne S.
    Krarup, Niels
    SICOT-J, 2015, 1
  • [30] A modified technique to extract fractured femoral stem in revision total hip arthroplasty: A report of two cases
    Akrawi, Hawar
    Magra, Merzesh
    Shetty, Ajit
    Ng, Aaron
    INTERNATIONAL JOURNAL OF SURGERY CASE REPORTS, 2014, 5 (07): : 361 - 364