An Update to a Novel Technique for Centering the Femoral Stem in Primary Total Hip Arthroplasty

被引:0
|
作者
Bono, Olivia J. [1 ]
Shields, John S. [2 ]
Schuett, Dustin J. [1 ]
Pinski, John [3 ]
Bono, James, V [4 ]
机构
[1] New England Baptist Hosp, Dept Orthopaed Surg, Boston, MA 02120 USA
[2] Wake Forest Baptist Hlth, Orthopaed Surg, Bermuda Run, NC USA
[3] Tufts Univ, Sch Med, Boston, MA 02111 USA
[4] New England Baptist Hosp, Dept Orthopaed Surg, Orthopaed, Boston, MA USA
来源
SURGICAL TECHNOLOGY INTERNATIONAL-INTERNATIONAL DEVELOPMENTS IN SURGERY AND SURGICAL RESEARCH | 2019年 / 35卷
关键词
SHAFT PERFORATION; ALIGNMENT; RESECTION;
D O I
暂无
中图分类号
R61 [外科手术学];
学科分类号
摘要
Careful surgical technique is a critical component of total hip arthroplasty. Femoral preparation and component positioning are vital to improving outcomes and preventing complications. Femoral preparation begins with creating an entry hole in the proximal femur. Various tools have been used for this purpose which resemble a "cookie cutter." An axial starter reamer, or awl, is then inserted through the entry hole in the proximal femur to aid in opening and centralizing the canal for sequential reaming or broaching. A novel technique was described previously which allows the awl to center itself in the canal with little risk of deviation from midline or cortical perforation. Since describing this technique in 2014, the senior surgeon has further modified the method of preparing the entry hole in the proximal femur. The surgeon now uses a 1/8 '' drill bit to penetrate the piriformis fossa, instead of a "cookie cutter" or osteotome. A 1/8 '' entry hole eliminates gaps between the bone and the implant, results in lateralization of the stem, and avoids varus malposition. We evaluated 300 primary hip arthroplasties by a single surgeon using one of the three techniques: traditional clockwise technique ( Group 1), our previously published novel counterclockwise technique (Group 2), and our updated novel technique (Group 3). While the deviation from midline of Group 3 did not differ significantly from Group 2, it was significantly less than the deviation from midline of Group 1 (p=00006). This simple updated technique enables the surgeon to avoid potential malalignment during femoral preparation.
引用
收藏
页数:4
相关论文
共 50 条
  • [11] The impact of a femoral stem collar on primary hip arthroplasty
    Kayani, B.
    Staats, K.
    Haddad, F. S.
    BONE & JOINT JOURNAL, 2024, 106B (09): : 879 - 883
  • [12] Total hip arthroplasty after osteosynthesis of proximal femoral fractures compared to primary Total hip arthroplasty
    Schleicher, Alisa
    Neidenbach, Philipp
    Blumel, Stefan
    Leunig, Michael
    Rudiger, Hannes
    SWISS MEDICAL WEEKLY, 2021, 151 : 22S - 22S
  • [13] Primary hybrid total hip arthroplasty with a roughened femoral stem: Integrity of the stem-cement interface
    Meneghini, RM
    Feinberg, JR
    Capello, WN
    JOURNAL OF ARTHROPLASTY, 2003, 18 (03): : 299 - 307
  • [14] Conservation of a stable femoral stem in total hip arthroplasty replacements
    Chiron, R.
    REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 2007, 93 (06): : 156 - 157
  • [15] REDESIGN OF THE FEMORAL STEM FOR A TOTAL HIP ARTHROPLASTY FOR ADDITIVE MANUFACTURING
    Hanks, Bradley
    Dinda, Shantanab
    Joshi, Sanjay
    PROCEEDINGS OF THE ASME INTERNATIONAL DESIGN ENGINEERING TECHNICAL CONFERENCES AND COMPUTERS AND INFORMATION IN ENGINEERING CONFERENCE, 2018, VOL 2A, 2018,
  • [16] The biomechanical effect of the collar of a femoral stem on total hip arthroplasty
    Jeon, Insu
    Bae, Ji-Yong
    Park, Jin-Hong
    Yoon, Taek-Rim
    Todo, Mitsugu
    Mawatari, Masaaki
    Hotokebuchi, Takao
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2011, 14 (01) : 103 - 112
  • [17] Revision total hip arthroplasty using the Zweymuller femoral stem
    Oetgen M.E.
    Huo M.H.
    Keggi K.J.
    Journal of Orthopaedics and Traumatology, 2008, 9 (2) : 57 - 62
  • [18] Revision Total Hip Arthroplasty With a Modular Cementless Femoral Stem
    Pelt, Christoper E.
    Madsen, Wes
    Erickson, Jill A.
    Gililland, Jeremy M.
    Anderson, Mike B.
    Peters, Christopher L.
    JOURNAL OF ARTHROPLASTY, 2014, 29 (09): : 1803 - 1807
  • [19] Fifteen-year Results of Precoated Femoral Stem in Primary Hybrid Total Hip Arthroplasty
    Suh, Dong Hun
    Yun, Ho Hyun
    Chun, Sung Kwang
    Shon, Won Yong
    CLINICS IN ORTHOPEDIC SURGERY, 2013, 5 (02) : 110 - 117
  • [20] Distal femoral shortening in total hip arthroplasty for complex primary hip reconstruction. A new surgical technique
    Koulouvaris, Panagiotis
    Stafylas, Kosmas
    Sculco, Thomas
    Xenakis, Theodore
    JOURNAL OF ARTHROPLASTY, 2008, 23 (07): : 992 - 998