Efficacy and safety of catheter ablation of atrioventricular nodal re-entrant tachycardia by means of flexible-tip irrigated catheters

被引:9
作者
Bertini, Matteo [1 ]
Brieda, Alessandro [1 ]
Balla, Cristina [1 ]
Pollastrelli, Annalisa [2 ]
Smarrazzo, Vittorio [1 ]
Francesco, Vitali [1 ]
Malagu, Michele [1 ]
Ferrari, Roberto [3 ]
机构
[1] Azienda Osped Univ Fenum, Cardiovasc Unit, Via Aldo Moro 8, I-44124 Ferrara, FE, Italy
[2] Abbott Med Italy, Clin Dept, Viale Thomas Alva Edison 110, I-20099 Sesto San Giovanni, MI, Italy
[3] Maria Cecilia Hosp, GVM Care & Res, Via Madonn Genova 1, I-48033 Cotignola, RA, Italy
关键词
Atrioventricular nodal re-entrant tachycardia; AVNRT; Catheter ablation; Irrigated catheter; Supraventricular tachycardia; 3D electroanatomic mapping; SUPRAVENTRICULAR TACHYCARDIA; PREDICTORS; MANAGEMENT; PATHWAY; FORCE;
D O I
10.1007/s10840-019-00578-z
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose Irrigated-tip ablation catheters increase safety and efficacy of ablation procedures, but their use in atrioventricular nodal re-entrant tachycardia (AVNRT) ablation has not been systematically evaluated. The aim of this study is to evaluate the safety and efficacy of radiofrequency (RF) catheter ablation of AVNRT by means of the novel flexible-tip open-irrigated catheter FlexAbility (TM) and a 3D electroanatomic mapping (EAM) system. Methods This is a single-center and single-operator study on 80 patients referred for AVNRT catheter ablation. Outcome included acute and long-term procedural success as well as complications reported over a median follow-up of 19 months (interquartile range 6-24 months). Results Acute success was achieved in all 80 patients. One procedure-related major complication, involving the vascular access, occurred. Mean fluoroscopy time was 106 +/- 71 s. One patient (1.2%) suffered long-term AVNRT recurrence. Five patients (6.2%) underwent ablation for AVNRT combined with ablation for other clinical arrhythmias. Conclusions Irrigated RF ablation of AVNRT by means of the novel flexible-tip open-irrigated catheter associated to 3D EAM system is effective and safe. Success rates are comparable to those of other techniques. Complication rate is very low.
引用
收藏
页码:61 / 67
页数:7
相关论文
共 50 条
[21]   Should fast pathway ablation be reconsidered in typical atrioventricular nodal re-entrant tachycardia? [J].
Tuohy, Stephen ;
Trulock, Kevin M. ;
Wiggins, Newton B. ;
Bassiouny, Mohammed ;
Ono, Maki ;
Kiehl, Eric L. ;
Cantillon, Daniel ;
Tarakji, Khaldoun ;
Tanaka, Christine ;
Dresing, Thomas ;
Saliba, Walid ;
Varma, Niraj ;
Tchou, Patrick .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2019, 30 (09) :1569-1577
[22]   A unified theory for the circuit of atrioventricular nodal re-entrant tachycardia [J].
Katritsis, Demosthenes G. .
EUROPACE, 2020, 22 (12) :1763-1767
[23]   Distal end of the atrioventricular nodal artery predicts the risk of atrioventricular block during slow pathway catheter ablation of atrioventricular nodal re-entrant tachycardia [J].
Lin, JL ;
Huang, SKS ;
Lai, LP ;
Lin, LJ ;
Chen, JH ;
Tseng, YZ ;
Lien, WP .
HEART, 2000, 83 (05) :543-550
[24]   Paradoxical Aging Changes of the Atrioventricular Nodal Properties in Patients With Atrioventricular Nodal Re-Entrant Tachycardia [J].
Tseng, Tzu-Wei ;
Hu, Yu-Feng ;
Tsai, Chin-Feng ;
Tsao, Hsuan-Ming ;
Tai, Ching-Tai ;
Lin, Yenn-Jiang ;
Chang, Shih-Lin ;
Lo, Li-Wei ;
Lee, Pi-Chang ;
Li, Cheng-Hung ;
Chao, Tze-Fan ;
Suenari, Kazuyoshi ;
Lin, Yung-Kuo ;
Chiang, Chern-En ;
Chen, Shih-Ann .
CIRCULATION JOURNAL, 2011, 75 (07) :1581-1584
[25]   Catheter ablation vs. antiarrhythmic drug therapy in patients with symptomatic atrioventricular nodal re-entrant tachycardia: a randomized, controlled trial [J].
Katritsis, Demosthenes G. ;
Zografos, Theodoros ;
Katritsis, George D. ;
Giazitzoglou, Eleftherios ;
Vachliotis, Vasilios ;
Paxinos, George ;
Camm, A. John ;
Josephson, Mark E. .
EUROPACE, 2017, 19 (04) :602-605
[26]   Successful percutaneous cryoablation of recurrent atrioventricular nodal re-entrant tachycardia after radiofrequency ablation [J].
Aliyev, Farid ;
Turkoglu, Cengizhan .
TURK KARDIYOLOJI DERNEGI ARSIVI-ARCHIVES OF THE TURKISH SOCIETY OF CARDIOLOGY, 2008, 36 (06) :407-411
[27]   Cryoablation vs. radiofrequency for therapy of atrioventricular nodal re-entrant tachycardia [J].
Katritsis, Demosthenes G. .
EUROPACE, 2019, 21 (04) :533-534
[28]   Atrioventricular block occurring several months after radiofrequency ablation for the treatment of atrioventricular nodal re-entrant tachycardia [J].
Elhag, O ;
Miller, HC .
HEART, 1998, 79 (06) :616-618
[29]   Safety and Efficacy of Temperature Controlled Irrigated Force Sensing Catheters in the Ablation of Atrioventricular Nodal Reentry Tachycardia. [J].
Nag, Tonusri ;
Chudow, Jay J. ;
Fattouh, Michael ;
Henriques, Matthew ;
Fisher, John D. ;
Ferrick, Kevin J. ;
Di Biase, Luigi ;
Kim, Soo G. ;
Romero, Jorge ;
Gross, Jay N. ;
Krumerman, Andrew .
CIRCULATION, 2018, 138
[30]   Radiofrequency Ablation for Pre-Excitation Syndromes and AV Nodal Re-Entrant Tachycardia [J].
Leitch, James ;
Barlow, Malcolm .
HEART LUNG AND CIRCULATION, 2012, 21 (6-7) :376-385