Bioimpedance spectroscopy and volumetry in the immediate/short-term monitoring of intensive complex decongestive treatment of lymphedema

被引:4
作者
Cavezzi, Attilio [1 ]
Urso, Simone U. [2 ]
Paccasassi, Stefania [1 ]
Mosti, Giovanni [3 ]
Campana, Fausto [4 ]
Colucci, Roberto [1 ]
机构
[1] Euroctr Venalinfa, Viale Dello Sport 14, I-63074 San Benedetto Tronto, Italy
[2] Osped Nobili, Castiglione Dei Pepoli, Italy
[3] Clin Barbantini, Angiol Unit, Lucca, Italy
[4] Villa Igea Forli, Forli, Italy
关键词
Lymphedema; bioimpedance spectroscopy; volumetry; complex decongestive therapy; resistance; reactance; PHASE-ANGLE; RELIABILITY; DIAGNOSIS; COMPRESSION;
D O I
10.1177/0268355520938578
中图分类号
R61 [外科手术学];
学科分类号
摘要
Aims To assess (a) immediate/short-term outcomes of intensive complex decongestive treatment of lower limb lymphedema, by means of bioimpedance spectroscopy and tape measurement-based volumetry, and (b) correlation between these two methods. Patients and methods Cohort study on patients affected by unilateral primary or secondary lymphedema, stage II or III. Patients underwent complex decongestive treatment (manual and electro-sound lymphatic drainage, compression bandage, exercises, low-carb nutrition, and dietary supplements) for six days. Before (D0), three and six days after complex decongestive treatment (D3 and D6), volumetry and bioimpedance spectroscopy data of the total limb and lower leg were collected. Statistical analysis was applied to pre-post treatment outcomes and to the volumetry/bioimpedance spectroscopy correlation. Results Forty-one patients (15 males and 26 females, mean age: 50.7 years) were included. A progressive improvement of volumetry and bioimpedance spectroscopy figures was recorded. Total limb and leg volumetry (mean value in cc) was, respectively, 11,072.9 and 3150.8 at D0, 10,493 (-5.2%, p = 0.001) and 2980.2 (-5.4%, p < 0.001) at D6. Total limb lymphatic index at D0 and D6 was 18.9 and 14.8 (-21.5%, p < 0.001). Total limb resistance at D0, D3, and D6 was 200.4, 225.7, and 237.5 (+18.5%, p < 0.001), respectively; leg resistance at D0 and D6 was 117.5 and 150 (+27.7%, p < 0.001), respectively. Total limb reactance at D0, D3, and D6 was 12.2, 15, and 16.6 (+35.5%, p < 0.001), respectively. Leg reactance at D0 and D6 was 7.7 and 11.5 (+ 49.6%, p < 0001), respectively. Correlation volumetry/bioimpedance spectroscopy data were (a) total limb volumetry/resistance rho = -0.449, p < 0.01; volumetry/reactance rho=-0.466, p < 0.01; volumetry/lymphatic index rho = 0.581, p < 0.01; (b) leg volumetry/resistance rho=-0.579, p < 0.01; volumetry/reactance rho=-0.469, p < 0.01; volumetry/lymphatic index rho = 0.466, p < 0.05. Conclusions Complex decongestive treatment on lymphedematous limbs was effective at short term; both volumetry and bioimpedance spectroscopy showed a statistically significant improvement. Resistance and reactance increase, with lymphatic index decrease, correlated with volumetry decrease. Bioimpedance spectroscopy proved to help to assess fluid decrease and the tissue-related parameters variations.
引用
收藏
页码:715 / 723
页数:9
相关论文
共 30 条
  • [1] [Anonymous], 2016, LYMPHOLOGY, V49, P170
  • [2] Casley-Smith JR, 1997, MODERN TREATMENT LYM, P41
  • [3] Cavezzi A, 2010, INT ANGIOL, V29, P392
  • [4] Cavezzi A, 2013, ISL WORLD C 2013
  • [5] Compression with 23mmHg or 35mmHg stockings after saphenous catheter foam sclerotherapy and phlebectomy of varicose veins: A randomized controlled study
    Cavezzi, Attilio
    Mosti, Giovanni
    Colucci, Roberto
    Quinzi, Valentina
    Bastiani, Luca
    Urso, Simone U.
    [J]. PHLEBOLOGY, 2019, 34 (02) : 98 - 106
  • [6] A new technique for the quantification of peripheral edema with application in both unilateral and bilateral cases
    Cornish, BH
    Thomas, BJ
    Ward, LC
    Hirst, C
    Bunce, IH
    [J]. ANGIOLOGY, 2002, 53 (01) : 41 - 47
  • [7] Cornish BH, 2001, LYMPHOLOGY, V34, P2
  • [8] Assessment of Breast Cancer-Related Arm Lymphedema-Comparison of Physical Measurement Methods and Self-Report
    Czerniec, S. A.
    Ward, L. C.
    Refshauge, K. M.
    Beith, J.
    Lee, M. J.
    York, S.
    Kilbreath, S. L.
    [J]. CANCER INVESTIGATION, 2010, 28 (01) : 54 - 62
  • [9] Deltombe T, 2007, LYMPHOLOGY, V40, P26
  • [10] Reliability and variability of bioimpedance measures in normal adults: Effects of age, gender, and body mass
    Dittmar, M
    [J]. AMERICAN JOURNAL OF PHYSICAL ANTHROPOLOGY, 2003, 122 (04) : 361 - 370