Transfemoral Aortic Valve Implantation in Patients With an Annulus Dimension Suitable for Either the Edwards Valve or the CoreValve

被引:15
作者
Watanabe, Yusuke [1 ]
Hayashida, Kentaro [1 ]
Yamamoto, Masanori [2 ]
Mouillet, Gauthier [2 ]
Chevalier, Bernard [1 ]
Oguri, Atsushi [2 ]
Dubois-Rande, Jean-Luc [3 ,4 ]
Morice, Marie-Claude [1 ]
Teiger, Emmanuel [2 ,4 ]
Lefevre, Thierry [1 ]
机构
[1] Inst Cardiovasc Paris Sud, Massy, France
[2] Henri Mondor Univ Hosp, AP HP, Dept Intervent Cardiol, Creteil, France
[3] Henri Mondor Univ Hosp, AP HP, Dept Med Cardiol, Creteil, France
[4] Univ Paris Est, Fac Med, Creteil, France
关键词
PERMANENT PACEMAKER; TRANSCATHETER; REGURGITATION; IMPACT; OUTCOMES; REGISTRY; RUPTURE; SAPIEN; TAVI; NEED;
D O I
10.1016/j.amjcard.2013.04.045
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The aim of this study was to compare the outcomes of transcatheter aortic valve implantation using the Edwards SAPIEN valve and the Medtronic Core Valve in patients with annulus of intermediate size (20 to 25 mm). From October 2008 to April 2012, 662 consecutive patients who underwent transcatheter aortic valve implantation were studied at 2 French centers. After propensity score matching, a total of 192 patients with intermediatesized aortic annulus who had received either Edwards (n = 96, mean age 82.4 +/- 7.9 years, 48% men, 61.9% receiving the 26-mm valve) or Core Valve (n = 96, mean age 82.5 +/- 7.7 years, 50% men, 64.6% receiving the 29-mm valve) prostheses through the transfemoral approach were studied. Adequate reduction in postprocedural mean pressure gradients was achieved with the Edwards valve and the Core Valve (10.9 +/- 4.7 vs 9.1 +/- 4.4 mm Hg, respectively, p <0.01). Major vascular complications (5.2% vs 3.1%, p = 0.36), device success (95.8% vs 93.8%, p = 0.52), and 30-day survival (90.6% vs 89.6%, p = 0.81) were similar. The incidence of postprocedural aortic regurgitation grade >= 2/4 and new pacemaker implantation was more frequent in the Core Valve group (14.3% vs 35.5%, p <0.01, and 4.2% vs 18.8%, p <0.01, respectively). There was no significant difference in 1-year cumulative survival rates in the Edwards valve group compared with the Core Valve group (80.1 +/- 4.2% vs 75.6 +/- 4.9%,,log-rank p = 0.31). In conclusion, in patients with annulus of intermediate size, similar device success and short-term and midterm outcomes were achieved with either of the valves, irrespective of the specific complications related to each valve. (C) 2013 Elsevier Inc. All rights reserved.
引用
收藏
页码:707 / 713
页数:7
相关论文
共 28 条
[1]   Prosthesis Oversizing in Balloon-Expandable Transcatheter Aortic Valve Implantation Is Associated With Contained Rupture of the Aortic Root [J].
Blanke, Philipp ;
Reinoehl, Jochen ;
Schlensak, Christian ;
Siepe, Matthias ;
Pache, Gregor ;
Euringer, Wulf ;
Geibel-Zehender, Annette ;
Bode, Christopher ;
Langer, Mathias ;
Beyersdorf, Friedhelm ;
Zehender, Manfred .
CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2012, 5 (04) :540-548
[2]   Transcatheter Aortic Valve Implantation With the Edwards SAPIEN Versus the Medtronic CoreValve Revalving System Devices A Multicenter Collaborative Study: The PRAGMATIC Plus Initiative (Pooled-RotterdAm-Milano-Toulouse In Collaboration) [J].
Chieffo, Alaide ;
Buchanan, Gill Louise ;
Van Mieghem, Nicolas M. ;
Tchetche, Didier ;
Dumonteil, Nicolas ;
Latib, Azeem ;
van der Boon, Robert M. A. ;
Vahdat, Olivier ;
Marcheix, Bertrand ;
Farah, Bruno ;
Serruys, Patrick W. ;
Fajadet, Jean ;
Carrie, Didier ;
de Jaegere, Peter P. T. ;
Colombo, Antonio .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 61 (08) :830-836
[3]   Influence of CoreValve ReValving System Implantation on Mitral Valve Function: An Echocardiographic Study in Selected Patients [J].
De Chiara, Benedetta ;
Moreo, Antonella ;
De Marco, Federico ;
Musca, Francesco ;
Oreglia, Jacopo ;
Lobiati, Elisabetta ;
Bruschi, Giuseppe ;
Belli, Oriana ;
Mauri, Francesco ;
Klugmann, Silvio .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2011, 78 (04) :638-644
[4]   Transcatheter aortic valve implantation: early results of the FRANCE (FRench Aortic National CoreValve and Edwards) registry [J].
Eltchaninoff, Helene ;
Prat, Alain ;
Gilard, Martine ;
Leguerrier, Alain ;
Blanchard, Didier ;
Fournial, Gerard ;
Iung, Bernard ;
Donzeau-Gouge, Patrick ;
Tribouilloy, Christophe ;
Debrux, Jean-Louis ;
Pavie, Alain ;
Gueret, Pascal .
EUROPEAN HEART JOURNAL, 2011, 32 (02) :191-197
[5]   Registry of Transcatheter Aortic-Valve Implantation in High-Risk Patients [J].
Gilard, Martine ;
Eltchaninoff, Helene ;
Iung, Bernard ;
Donzeau-Gouge, Patrick ;
Chevreul, Karine ;
Fajadet, Jean ;
Leprince, Pascal ;
Leguerrier, Alain ;
Lievre, Michel ;
Prat, Alain ;
Teiger, Emmanuel ;
Lefevre, Thierry ;
Himbert, Dominique ;
Tchetche, Didier ;
Carrie, Didier ;
Albat, Bernard ;
Cribier, Alain ;
Rioufol, Gilles ;
Sudre, Arnaud ;
Blanchard, Didier ;
Collet, Frederic ;
Dos Santos, Pierre ;
Meneveau, Nicolas ;
Tirouvanziam, Ashok ;
Caussin, Christophe ;
Guyon, Philippe ;
Boschat, Jacques ;
Le Breton, Herve ;
Collart, Frederic ;
Houel, Remi ;
Delpine, Stephane ;
Souteyrand, Geraud ;
Favereau, Xavier ;
Ohlmann, Patrick ;
Doisy, Vincent ;
Grollier, Gilles ;
Gommeaux, Antoine ;
Claudel, Jean-Philippe ;
Bourlon, Francois ;
Bertrand, Bernard ;
Van Belle, Eric ;
Laskar, Marc .
NEW ENGLAND JOURNAL OF MEDICINE, 2012, 366 (18) :1705-1715
[6]   Impact of TAVI on Mitral Regurgitation: A Prospective Echocardiographic Study [J].
Giordana, Francesca ;
Capriolo, Michele ;
Frea, Simone ;
Marra, Walter Grosso ;
Giorgi, Mauro ;
Bergamasco, Laura ;
Omede, Pier Luigi ;
Sheiban, Imad ;
D'Amico, Maurizio ;
Bovolo, Virginia ;
Salizzoni, Stefano ;
La Torre, Michele ;
Rinaldi, Mauro ;
Marra, Sebastiano ;
Gaita, Fiorenzo ;
Morello, Mara .
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2013, 30 (03) :250-257
[7]   Potential Mechanism of Annulus Rupture During Transcatheter Aortic Valve Implantation [J].
Hayashida, Kentaro ;
Bouvier, Erik ;
Lefevre, Thierry ;
Hovasse, Thomas ;
Morice, Marie-Claude ;
Chevalier, Bernard ;
Romano, Mauro ;
Garot, Philippe ;
Farge, Arnaud ;
Donzeau-Gouge, Patrick ;
Cormier, Bertrand .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2013, 82 (05) :E742-E746
[8]   Impact of Post-Procedural Aortic Regurgitation on Mortality After Transcatheter Aortic Valve Implantation [J].
Hayashida, Kentaro ;
Lefevre, Thierry ;
Chevalier, Bernard ;
Hovasse, Thomas ;
Romano, Mauro ;
Garot, Philippe ;
Bouvier, Erik ;
Farge, Arnaud ;
Donzeau-Gouge, Patrick ;
Cormier, Bertrand ;
Morice, Marie-Claude .
JACC-CARDIOVASCULAR INTERVENTIONS, 2012, 5 (12) :1247-1256
[9]   Impact of CT-guided valve sizing on post-procedural aortic regurgitation in transcatheter aortic valve implantation [J].
Hayashida, Kentaro ;
Bouvier, Erik ;
Lefevre, Thierry ;
Hovasse, Thomas ;
Morice, Marie-Claude ;
Chevalier, Bernard ;
Romano, Mauro ;
Garot, Philippe ;
Mylotte, Darren ;
Farge, Arnaud ;
Donzeau-Gouge, Patrick ;
Cormier, Bertrand .
EUROINTERVENTION, 2012, 8 (05) :546-555
[10]   Cross-Sectional Computed Tomographic Assessment Improves Accuracy of Aortic Annular Sizing for Transcatheter Aortic Valve Replacement and Reduces the Incidence of Paravalvular Aortic Regurgitation [J].
Jilaihawi, Hasan ;
Kashif, Mohammad ;
Fontana, Gregory ;
Furugen, Azusa ;
Shiota, Takahiro ;
Friede, Gerald ;
Makhija, Rakhee ;
Doctor, Niraj ;
Leon, Martin B. ;
Makkar, Raj R. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (14) :1275-1286